Loading...
HomeMy WebLinkAboutProject Information Customer: Mullen WorkOrder Number: 05132019001N0601 Unit Con- Wall Opening Opening Shutter Shutter Anchor Storm Bars No. tract Pressure Width Height Width Height Spacing Inside Outside No. Qty.1 Length Qty. Length 1 1 -32.8 81.5 152.5 81.5 152.5 6"o.c. 0 0 0 0 6"o.c. / ASCE 7-10 Design Wind Loads wind speed V= 160 mph Exposure t' _ L For Wall Components &Cladding easyseals.corTt ASD Load Combination Coefficient: 0.6 Wind Pressures[psf]For use with Allowable Stress Design KZt= 1.0 Kd= 0.85 Enclosed Bldg GCpi= 0.18 Triburary area at least... Triburary area at least... Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Mean 10 sq ft 15 sq ft 20 sq ft 25 sq ft 30 sq ft 35 sq ft 40 sq ft 50 sq ft Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Height Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner u + + + + + + + + + + + - + - + - + - + - + - 15 ft +33.5-36.3 +33.5-44.8 +32.6-35.4 +32.6-43.1 +32.0-34.8 +32.0 41.8 +31.5-34.3 +31.5-40.8 +31.1-33.9 +31.1-40.0 +30.8-33.6 +30.8-39.4 +30.5-33.3 +305-38.8 +30.0-32.8, +30.0-37.8 16 ft +33.9-36.8 +33.9-45.4 +33.0-35.9 +33.0-43.7 +32.4-35.3 +32.4-42.4 +31.9-34.8 +31.9-41.4 +31.5-34.4 +31.5-40.6 +31.2-34.1 +31.2-39.9 +30.9-33.8 +30.9-39.3 +30.4-33.3 +30.4-38.3 17 ft +34.4-37.3 +34.4-46.0 +33.5-36.4 +33.5-44.2 +32.8-35.7 +32.8-42.9 +32.3-35.2 +32.3-41.9 +31.9-34.8 +31.9-41.1 +31.6-34.5 +31.6-40.4 +31.3-34.2 +31.3-39.8 +30.8-33.7 +30.8-38.8 18 ft +34.8-37.7 +34.8-46.6 +33.9-36.8 +33.9-44.7 +33.2-36.2 +33.2-43.4 +32.7-35.7 +32.7-42.4 +32.3-35.3 +32.3-41.6 +32.0-34.9 +32.0-40.9 +31.7-34.6 +31.7-40.3 +31.2-34.1 +31.2-39.3 20 ft 1 +35.6-38.6 +35.6-47.6 +34.6-37.6 +34.61-45.8 +34.0-37.0 +34.0-44.4 +33.5.-36.5 +33.5-43.4 +33.0-36.0 +33.0-42.5 +32.7.-35.7 +32.7-41.8 +32.41-35.4 +32.4-41.2 +31.8.-34.9 +31.81-40.2 22 ft +36.3-39.4 +36.3-48.6 +35.3-38.4 +35.3-46.7 +34.7-37.7 +34.7-45.3 +34.1-37.2 +34.1-44.3 +33.7-36.8 +33.7-43.4 +33.3-36.4 +33.3-42.7 +33.0-36.1 +33.0-42.1 +32.5-35.6 +32.5-41.0 24 ft +37.0-40.1 +37.0-49.5 +36.0-39.1 +36.0-47.5 +35.3-38.4 +35.3-46.2 +34.8-37.9 +34.8-45.1 +34.3-37.5 +34.3-44.2 +34.0-37.1 +34.0-43.5 +33.6-36.8 +33.6-42.8 +33.1-36.2 +33.1-41.8 25 ft +37.3-40.4 +37.3-49.9 +36.3-39.5 +36.3-48.0 +35.61-38.8 +35.6-46.6 +35.1-38.2 +35.1-45.5 +34.6-37.8 +34.6-44.6 +34.2-37.4 +34.2-43.8 +33.9-37.1 +33.9-43.2 +33.4-36.5 +33.4-42.1 26 ft +37.6-40.8 +37.6-50.3 +36.61-39.8 +36.6-48.4 +35.9-39.1 +35.9-46.9 +35.4-38.5 +35.4-45.9 +34.9-38.1 +34.9-45.0 +34.5-37.7 +34.5-44.2 +34.2-37.4 +34.2-43.6 +33.7-36.8 +33.7-42.5 28 ft 1 +38.2-41.4 +38.2-51.1 +37.2-40.4 +37.2-49.1 +36.5-39.7 +36.5-47.7 +35.91-3 9.1 +35.9-46.6 +35.5-38.7 +35.5-45.7 +35.1-38.3 +35.1-44.9 +34.7-38.0 +34.7-44.2 +34.2-37.4 +34.2-43.1 30 ft +38.7 42.0 +38.71-51.9 +37.7 41.0 +37.7-49.8 +37.0-40.3 +37.01-48.4 +36.4-39.7 +36.4-47.3 +36.0-39.3 +36.0-46.3 +35.6-38.9 +35.6-45.6 +35.2-38.5 +35.2-44.9 +34.7-38.0 +34.7-43.8 32 ft +39.3-42.6 +39.3-52.6 +38.2-41.6 +38.2-50.5 +37.5-40.8 +37.5-49.0 +36.9-40.3 +36.9-47.9 +36.5-39.8 +36.5-47.0 1 +36.1-39.4 +36.1-46.2 +35.7-39.1 +35.7-45.5 +35.2-38.5 +35.2-44.4 34 ft +39.8-43.1 +39.8-53.3 +38.7-42.1 +38.7-51.2 +38.0-41.4 +38.0-49.7 +37.4-40.8 +37.4-48.5 +36.9-40.3 +36.9-47.6 +36.5-39.9 +36.5-46.8 +36.21-39.6 +36.2-46.1 1 +35.6-39.0 +35.6-44.9 35 ft +40.0-43.4 +40.0-53.6 +39.0142.4 +39.0-51.5 +38.2-41.6 +38.2-50.0 +37.6-41.0 +37.6-48.8 +37.2-40.6 +37.2-47.9 +36.8-40.2 +36.8-47.1 +36.4-39.8 +36.4-46.4 +35.8-39.2 +35.8-45.2 36 ft +40.3-43.7 +40.3-53.9 +39.2-42.6 +39.2-51.8 +38.4-41.9 +38.4-50.3 +37.91-41.3 +37.9-49.1 +37.4-40.8 +37.4-48.2 +37.0-40.4 +37.0-47.3 +36.6-40.0 +36.6-46.6 +36.0-39.5 1 +36.0-45.5 38 ft +40.7-44.2 +40.71-54.5 +39.6 43.1 +39.6-52.4 +38.9-42.3 +38.9-50.8 +38.3-41.7 +38.3-49.7 +37.8-41.3 +37.8-48.7 +37.4-40.9 +37.41-47.9 +37.0-40.5 +37.0-47.2 +36.5-39.9 +36.5-46.0 40 ft +41.2-44.6 +41.2-55.1 +40.1-43.6 +40.1-52.9 +39.3-42.8 +39.3-51.4 +38.7-42.2 +38.7-50.2 +38.2-41.7 1 +38.2-49.2 +37.8-41.3 +37.8-48.4 +37.4-40.9 +37.4-47.7 +36.9-40.3 +36.9-46.5 42 ft +41.6-45.1 +41.6-55.7 +40.5-44.0 +40.5-53.5 +39.7-43.2 +39.7-51.9 +39.1-42.6 +39.1-50.7 +38.6-42.1 +38.6-49.7 +38.2-41.7 +38.2-48.9 +37.8-41.4 +37.8-48.2 +37.2-40.8 +37.2-47.0 44 ft +42.0-45.6 +42.0-56.2 +40.91-44.4 +40.9-54.0 +40.1-43.7 +40.1-52.4 +39.5-43.1 +39.5-51.2 +39.0-42.6 +39.0-50.2 +38.61-42.1 +38.6-49.4 +38.2-41.8 +38.2-48.7 +37.61-41.2 +37.6-47.4 45 ft +42.2-45.8 +42.2-56.5 +41.1-44.7 +41.1-54.3 +40.3-43.9 +40.3-52.7 +39.7-43.3 +39.7-51.5 +39.2-42.8 +39.2-50.5 +38.8-42.3 +38.8-49.6 +38.4-42.0 +38.4-48.9 +37.8-41.4 +37.8-47.7 46 ft +42.4-46.0 1 +42.41-56.8 +41.3-44.9 +41.3 1-54.5 1 +40.5-44.1 +40.5-52.9 1 +39.9-43.5 +39.9-51.7 +39.4-43.0 +39.4-50.7 +38.9-42.5 +38.9-49.9 +38.6-42.2 +38.6-49.1 +38.0-41.5 +38.0-47.9 48 ft +42.8-46.4 +42.8-57.3 +41.6-45.3 +41.6-55.0 +40.8-44.5 +40.8-53.4 +40.2-43.8 +40.2-52.2 +39.7-43.3 +39.71-51.2 +39.3-42.9 +39.3-50.3 +38.9-42.5 +38.9-49.6 +38.3-41.9 +38.3 48.3 50 ft +43.1-46.8 +43.1-57.8 +42.0-45.7 +42.0-55.5 +41.2-44.9 1 +41.2-53.9 +40.6-44.2 +40.6-52.6 +40.1-43.7 +40.1-51.6 +39.6-43.3 +39.6-50.7 +39.3-42.9 +39.3-50.0 +38.6-42.3 1 +38.6-48.7 52 ft +43.5-47.2 +43.5-58.2 +42.31-46.0 +42.3-55.9 +41.5-45.2 +41.5-54.3 +40.9-44.6 +40.9-53.1 +40.4-44.1 +40.4-52.0 +40.0-43.6 +40.0-51.2 +39.6-43.3 +39.6-50.4 +38.9-42.6 +38.9-49.1 54 ft +43.8-47.6 +43.8-58.7 +42.7-46.4 +42.7-56.4 +41.9-45.6 +41.9-54.8 +41.21-44.9 +41.2-53.5 +40.7-44.4 +40.7-52.4 40.31-44.0 1 +40.3-51.6 +39.9-43.6 +39.9-50.8 +39:3-43.0 +39.3-49.5 55 ft +44.0-47.7 +44.0-58.9 +42.9-46.6 +42.91-56.6 +42.0-45.8 +42.0-55.0 +41.4-45.1 +41.4-53.7 +40.9-44.6 +40.9-52.6 +40.4-44.2 +40.4-51.8 +40.0-43.8 +40.0-51.0 +39.4-43.1 +39.4-49.7 56 ft +44.2-47.9 +44.2-59.2 +43.0-46.8 +43.0-56.8 +42.2-45.9 +42.2-55.2 +41.5-45.3 +41.5-53.9 +41.0-44.8 +41.0-52.8 +40.6-44.3 +40.6-52.0 +40.2-43.9 +40.2-51.2 +39.6-43.3 +39.6-49.9 58 ft +44.5-48.3 +44.5-59.6 +43.3-47.1 +43.3-57.2 42.5-46.3 +42.5-55.6 +41.9-45.6 +41.9-54.3 +41.3-45.1 +41.3-53.2 +40.9-44.7 +40.5-44.3 +40.5-516 +399-436 +39..91-50.3 60ft +44.8-48.6 +44.8-60.0 +436 47.4 +43.6-57.7 -51.9 3.9 U-1 -Design conforms to the Florida Building Code 6th Ed(2017). •Wind Speed noted above is ultimate design wind speed(3-second gust). •Zones 4&5("Interior"and"corner"zones,respectively)are as shown to a a Valid only with a eer's LV -Tabulated design wind loads are based on ASCE 7-10 specifications for •Plus(+)&minus(-)signs signify pressures acting toward and away from the right,where the dimension"a"is the minimum of 10%of the building's Osignat &rais seal components and cladding based on design criteria as noted herein. the exterior component or cladding surface,respectively. least horizontal dimension or 40%of the mean roof height,but never lessPMeanRwfHt Z •Where this document is used for permit,applicability of design criteria •Where"Mean(average)Roof Height"cannot be'determined,peak roof than T-0"or 4%of the least horizontal dimension.J noted herein(Basic Wind Speed,Exposure Category,Risk Category,etc.) height shall be used,except that eave height shall be used for roof angle •This specification is valid only for use with structures NOT located in the `f shall be verified by the contractor&building official prior to construction. less than or equal to 30°.Round up to values shown upper one-half of an isolated hill,ridge or escarpment. an OgThis specification may be used in conjunction with engineering under -Wind pressures are applicable to all building floors. •This specification is valid for use with buildings of any Risk Category,LLI separate certification(by this engineer or by others)using Allowable Stress •Tabulated wind pressures are valid for all roof slopes;no reduction for including essential facilities and buildings or other structures that Z Design(ASD). roof slope 510°has been considered. represent a substantial hazard to human life in the event of failure. Christian Langle9#31124 E 1W7 •Refer to the above-noted ASCE 7 standard for descriptions and •Tributary Area noted in table(effective wind area)is equal to the -Design is based on structure classification as Enclosed Bldg Peaegt FL PE#67382 definitions of all design criteria. minimum of[height x width]or[ht x ht/3].Round down to values shown. wai A Fi UMM 1200 N Federal Hwy,#200,Boca Raton,FL 33432 Copyright©2018 Easy Seals rev 0118 Doc No.A101.5.160C