Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Load Calculation
wF"ILE RECEIVED JUN 2 4 2019 ST. Lucie County, Permitting Property Information Building Information Owner: Welch Wind Zone: 160 MPH. Address: 15 Mariposa Ln Exposure Category: B Port St Lucie,F134952 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number IL Zone IF Width(in) I Height(in) IFElevation(ft)jl Pressure(psf) Pressure(psf) 1 End 52 54 7 31.1 -40.7 --- ...................-----...-..................._......._._.._..._._._...............- - ----.._..-------- ._................_..- --._...._ .._._.... —...-.............._.... 2 Int 37 80 7 31.0 =33.7 _..__.._:__._..........._._.__.............._.............................— -........... -- ...........---..-...._...................................._........._..._..- ........... - -- — - 3 Int 25.5 39 7 32.5 -35.2 _.......................................__.......-----._..........._.. - ----------.._.__......................__._...--.._.__..._..................._.._._....----- ---- 4 Int 25.5 39 7 32.5 -35.2 _._.—_................. .............._..-.......................-- -..-.............-- --._.. ...._......._........................_................................_....... --- 5 Int 73 54 7 30.4 -33.1 ------ -.........._-._.._....--..._.........................._..-.__..__..__.._.............-................._....----...—..._.... —...._... .._...- ----- 6 Int 52 54 7 31.1 -33.8 7 End 52 54 7 31.1 -40.7 8 End 37 80 7 31.0 -40.4 9 Irit. 52 54 7 31.1 -33.8 10 Int 52 54 7 31.1 -33.8 11 Int 36 54 7 31.8 -34.6 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1