Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Load Calculation
Property Information Building Information Owner: Corbin Wind Zone: 150 MPH. Address: 450 Campbell Rd Exposure Category: B Ft Pierce,F134945 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. JR Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number E Zone Width(in) Height(in) IFElevation(ft) Pressure(psf) Pressure(psf) 1 End 74 62 7 26.4 -33.9 2 Int 37 80 7 27.2 -29.6 3 Int 48 18 7 28.5 -31.0 4 Int 48 18 7 28.5 -31.0 5 End 48 18 7 28.5 -38.2 6 Int 53 62 7 27.0 -29.4 7 Int 37 38 7 28.5 -31.0 8 Int 36 80 7 27.3 -29.7 9 Int 24 18 7 28.5 -31.0 10 Int 24 18 7 28.5 -31.0 11 End 48 18 7 28.5 -38.2 12 Int 48 18 7 28.5 -31.0 13 Int 48 18 7 28.5 -31.0 14 Int .36 36 80 7 27.3 -29.7 15 Int 36 80 7 27.3 -29.7 16 End -- 27 38 7 28.5 -38.2 17 Int 53 38 7 27.9 -30.3 18 Int 48 18 7 28.5 -31.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Mnd Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1