HomeMy WebLinkAboutWind Load Calculation WINDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE - NUMBER + PSF + PSF TESTED MULLION ( ) (-)PSF ( ) (-)PSF SIZE DIMENSIONS REQ Y/NINA REQ Y/N 1 Int window Wet Glaze FL 8153.1 +50 -50 38.1 -41.5 53"x 96" 51x61 No No 2 Int window Wet Glaze FL 8153.1 +50 -50 40.1 -43.5 53"x 96" 24x61 No No 3 Int window Wet Glaze FL 8153.1 +50 -50 39.1 -42.5 53"x96" 35x61 Yes No 4 Int Window Wet Glaze FL 8153:1 +50 -50 39.1 -42.5 53"x 96" 35x61 Yes No 5 Int Door Wet Glaze FL 16520.2 +80 -80 36.6 -40.0 60x95 No No 6 Int Door Wet Glaze FL 16520.2 +80 -80 35.3 -38.7 96x95 No No 7 Int Window Wet Glaze FL 14590.1 +50 -50 38.4 -41.8 52.5°X83.5° 47x59 Yes No 8 Int Window Wet Glaze FL 14590.1 +50 -50 38.4 -41.8 52.5"x83.5" 47x59 Yes No 9 Int window Wet Glaze FL 8153.1 +50 -50 38.8 -42.2 53"x96" 51x48 No No 10 Int window Wet Glaze FL 8153.1 +50 -50 38.8 -42.2 53"x96" 51x48 No No 11 Int window Wet Glaze FL 8153.1 +50 -50 39.8 -43.2 53"x 96" 35x48 Yes No 12 Int Window Wet Glaze FL,8153.1 +50 -50 39.8 -43.2 53"x96" 35x48 Yes No X c � 3 �I i RECEIVED MAX(6G' UARD JUN 2 6 ZO 19 ORRIVAIVE WINDOW ST. Lucie County, Permitting 2253 Vista Pkviy#12 West Palm Beach,FL 33411 Property Information Building Information Owner: Donald or Ruth Pritsch Wind Zone: 170 MPH. Address: 8111 Carnousite PI Exposure Category: C Port St Lucie,FL 34986 Minimum Building Dimension: 35 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) ][:Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 51 61 7 38.1 -41.5 2 Int 24 61 7 40.1 -43.5 3 Int 35 61 7 39.1 -42.5 4 Int 35 61 7 39.1 -42.5 5 Int 60 95 7 36.6 -40.0 6 Int 96 95 7 35.3 -38.7 7 Int 47 59 7 38.4 -41.8 8 Int 47 59 7 38.4 -41.8 9 Int 51 48 7 38.8 -42.2 10 Int 51 48 7 38.8 -42.2 11 Int 35 48 7 39.8 -43.2 12 Int 35 48 7 39.8 -43.2 ALE ""L;%jDv i Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 1 of 1