Product Approval Menu > Product or Anplication Search > Application Lis[ > Application Detail
loll III
FL # FL12328-R8
Application Type Revision
Code Version 2017 Ip
Application Status Approved Q)
Comments(
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE -74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4869
2016
ASTM D6380
2003
TAS 103
1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgtF2Aezuarjg01... 1/29/2019
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
Method 1 Option D
10/05/2017
10/19/2017
10/20/2017
12/12/2017
FL # I Model, Number or Name I Description
Page 2 of 3
12328.1 ASTM Slate Surfaced Roll Roofing
Roll roofing surfaced with mineral granules
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 RS II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ: Yes
Underlavments final.pdf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
12328.2
ASTM Tile Underlayment
Coated organic underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
112328.3 I Master Smooth I Asphalt saturated organic underlayment.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
12328.4
Moisture Guard
A self -adhering modified bitumen underlayment.
t=Limits of
Installation Instructions
for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva] Report TAMKO
Underlavments rinal.odf
Created by Independent Third Party: Yes
12328.5
No. 15 ASTM
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Created by Independent Third Party: Yes
12328.6 1 No. 15 UL I Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ: Yes Underlavments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOl... 1/29/2019
CREEK Certificate of Authorization No. 2982417520 Edinburgh DriveTampa, FL 33647
-
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer:
TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
Smooth
P.O. Box 1404
Joplin, MO 64802
�1
(417) 624-6644
TAMKO® Moisture
http://www.tamko.com
Quality Assurance:
UL LLC (QUA9625)
SCOPE
removable selvedge release tape.
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1
Properties:
Physical properties
PRODUCT DESCRIPTION
saturated with asphalt.
TAMKO® ASTM Slate
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing
with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO® ASTM Tile
ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated
Underlayment
with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO® Master
ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
�1
TAMKO® Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard®
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO® No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 15 UL
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 30 ASTM
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 30 UL
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® TW Metal and
Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment
with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW
Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment
polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
[A CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKOO TAM -FELT Alternate to ASTM D 226, Type I and Type 11 underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO® TW Metal and Tile Underlayment and TAMKOO TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Metal Roof
Mineral
Wood
Asphalt
Panels and
Surfaced Roll
Shingles and
Slate
Clay and
Underlayment
Shingles
Shingles
Roofing
Shakes
Shingles
Concrete Tile
TAMKOO ASTM Slate
Surfaced Roll Roofing
Y'
N
N
N
N
Y
TAMKO® ASTM Tile
Underlayment
N
N
N
N
N
Y
TAMKO® Master Smooth
Y'
N
N
N
N
N
:TAMO@ Moisture GuardOO
Y
N
N
N
N
N
MKOO No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Yz
N
N
Felt
TAMKO AO No. 15 UL Asphalt
Saturated Organic Felt
Y
Y
Y
Yz
Y
N
TAMKOO No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKO® No. 30 UL Asphalt
Saturated Organic Felt
Y
Y
Y
N
Y
N
TAMKOO TW Metal and Tile
Underlayment
Y
Y
N
N
N
Y
TAMKOV TW Underlayment
Y
Y
N
N
N
N
TAMKOO TAM -FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
r�lIlllllllllGRK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
LM TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entice
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
TAP -192-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP -193-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP -214-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP -215-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP -216-02-03
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP -217-02-01 REV
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP -218-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP -219-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP -220-02-01
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP -222-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP -245-02-01
TAS 103
1995
ASTM D 4798
2011
PRI Construction Materials Technologies (TST6049)
TAP -311-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP -319-02-01.1
ACC 188
2012
PRI Construction Materials Technologies (TST6049)
TAP -387-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP -388-02-01
ASTM D 1970
2015a
UL LLC (TST9628)
13CA12269
ASTM D 226
2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R.
E N
No 74021
�'. STATE OF :ZIJ
.FS, �0Rt...
S;0 N Ai
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
�..,.�.,a���...., —04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.