Loading...
HomeMy WebLinkAboutDrawingsGENERAL' Automatic Transfer Switches Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Singe Phase C Sus LISTED TUL only applies to nor -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution"' or Nexus-" Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available it a service rated equipment configuration. _ Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint_ The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well; providing the most installation efficient power management options available, M =. 211111111 Sol 9 Doi: 2008 GENERAL' 100-400 Amps, Single Phase Functions Automatic Smart Transfer Switches All liming and sensing €unctions originate in the generator controller Utility voltage drop -out ................................................... .. <65% Timer to generator start..................................................................................................10 second factory set, adjustable between 2--1500 seconds by a qualified dealer" Enginewarm up delay.................................................................................................................................................................................................................5 seconds StandbyVoltage sensor ............... ....................................................... .................................................................. .................. ............................... .........65% for 5 seconds Utilityvoltage pickup ......... .................................. —............................ .................. ............. ,............................... ............................................... ............... .................>80% ReHransfertime delay.............................................................................................................................................................................................................15 seconds Enginecoal -down timer. ........... ...................... .................................... _ ....... ... .................. ................. _ ................................................ ................ _ 50 seconds Exerciser .............................. .............................. ......................... ..................... ............ ....... — ............ ................. 5 or 12 minutes adjustable weekly/Bi-weekly/Monthly', The transfer switch can be operated manually without power applied. 'When used in conjunction with un'lts utilizing Evolution— controls —Adjustable via the controller specifications Im Model RXS0100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW20UA3 RXSW300A3 RXSC400A3 RXSW400A3 Amps 100 100 150 20U 200 300 400 400 Voltage 120/240, 10 120/240, 1a 120/240, io 12U/240, I 120/240, 10 120/240, 10 120/240, fo 120/240, 10 Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3R NEMA/UL 3R NEMA/UL 313 NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 313 NEMA/UL 311 UL Rating UL/CUL UL UL UL/CUL UL UL UL/GUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MGM - #4 or 1/0 - 250 MGM Model RXSCIODA3 RXSWIOOA3 RXSW15OA3 RXSC200A3 RXSW20OA3 RXSW3t)OA3 RXSC400A3 RXSW40OA3 Height H1 17.24/437,9 17.241437.9 26.75/679A 1124/437A 26.75/679.4 42.9111069-9 31,25/793.8 42.91/1089.9 (in./mm) H2 20/508 201508 30/762 20/503 301762 48/1219.2 36/914.4 48/1219.2 Width W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10,51266.7 16.691423.9 19.18/487.2 16.69/423.9 {inJmm) W2 14.6/370.8 14.61370,8 13.5/342.9 14.6/3708 13.5/342.9 21.M54.2 24/609.6 21.82/554.2 Depth (inJmm) 7.09/100.1 7,091180.1 6.3/160.1 7.09/1801 6.3/160,1 10.06/255.5 10.06/255.5 10.06/255.5 Waight(Ibs(kilos} 20/9.07 22.5/10.21 I 39/17,69 20/9.07 39/11.59 140/63.5 133160.33 140/63.5 -DEPTH-] GENERAL' Generac Power Systems, Inc, • S45 W29290 HWY. 59, Waukesha, WI 53139 • gene rac.cunn EMMENEW '--)2017 Generac Power SyMms, Inc. Ali rights reserved. All specilications are subject to change wihoul notice. Bulletin 1000001 3459-A 04/24/17 Electrical Load Calculations Project: M-c-,Le.-<I_ Location: 3flOf' M,e,,e•tcGe-2 Existing Service Feeder / Size: ?,6 Main Breaker Size: Existing Loads: 2'-'Y Sq. Ft. X 3 watts per sq. ft................ . Appliance cir. @ 1500 watts ............. . . .. . Laundry cir. @ 1500 watts .......... . .......... . Range @ 8......... ............................. Dishwasher and disposal @ 1500 watts each Microwave @ 2000 watts,. . .......... Water heater @ 4.5 kw ................. Tankless water heater ............ . Dryer @ 5 kw .............. . Refrigerator er 1500 watts .............. ....... . Bathroom 1 @ 1500 watts ................ Sprinkler Pump .. . ................ . PooI.._......._ Other ................. TOTAL ................... ... New Loads: Poolpump ...... ............ ...................... Pool light, ........ . Heatpump ........................................ Chlorine generator.,.., . ....... . Air blower .................... . . . Boatlift............... .............................. Other. . .. . Other .................... . Other............ First 10 kw @ 100%.................. . ................. �76 TL Remainder @ 40%....................................... I �ODZ7 A/C heat @ 100%............. Total Watts / 240 volts = amps f �% Prepared ley: V C]k' Home 10 q5V_ watts CLo watts I S0 o watts a watts 1 watts L2<�Oo watts SU[� watts watts �CX=U watts watts watts. ,-) D watts watts watts 7Z watts Home watts watts watts watts watts watts Generator ID Sd2 watts 3000 watts watts Loe_cCS ,, watts 1 9-00 watts Zoo U watts watts watts LOc,rJ-5Mwatts watts watts �-O 0 D watts watts watts U t S Z watts Generator watts watts watts watts watts watts watts watts watts watts watts Horne l occ) watts H 0600 watts / 5 � watts Total Watts / 2 watts Generator �-o / SZ watts 0 watts Load Shed watts 40 volts = amps Date: i 3 .l� M I Michelle Franklin, CFA -- Saint Lucie County Property Appraiser --All rights reserved. Property Identification Site Address: 3404 Parcel ID: 2408-702-0006- Account #: 20708 Sec/TowwRange. 08/35SI40E MENENDEZ AVE 000-5 Map ID: 24/08S Zoning: RS-3 Use Type: 0100 Jurisdiction: Saint Lucie County Ownership Legal Description ARC of St Lucie County Inc DARK ITAMMOCK ESTATES -UNIT ONE- BLK 2 LOT 4 AND PO Box 1016 W 17 FT OF LOT 5 (0.46 AC) (OR 1536-589 : 1814-1230) Fort Pierce, FL 34954 Current Values Historical Values 3-year Just/Market: $192,600 Assessed: $192,600 Year Just/Market Assessed Exemptions Taxable Exemptions. $192,600 Taxable: $0 2018 $192,600 $192,600 $192,600 $0 2017 $175,100 $175,100 $175,100 $0 2016 $166,200 $163,570 $I63,570 $0 Sale History Date Book/Page Sale Code Deed Grantor Price 05-16-2002 1536 / 0589 XX01 WD Bishop Of Diocese Palm Beach $145,000 07-21-1988 0596 / 0470 XX00 WD Trabulsy Norman M $130,000 Primary Building Information Finished Area of this building: 3,484 SF Gross Sketched Area: 5,982 SF View: Year Built: 1966 Primary Wall: Cone Block Bedrooms: 4 Full Baths: 3 Half Baths: I Roof Cover. Dim Shingle Frame: Story Height: 1 Story A/C %: 100% Heated %: 100% Sprinkled.%: N/A% Exterior Data Roof Structure: Gable Grade: B- No. Units: I Interior Data Electric: MAXIMUM Heat Type: FrcdHotAir Heat Fuel: ELEC Total Areas Building Type: HB- Effective Year: 1976 Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Tile -Ceramic Finished/Under Air 3,484 (SF): Gross Sketched Area 5,982 (SF): Land Size (acres): 0.46 Land Size (SF): 20,037.6 Total Building Count: I Special Features and Yard Items Type Qty Units Year Blt RES POOL AVG 1 648 1977 Driv-Concret 1 1800 1977 POOL DK-AVG 1 514 1977 CHAINLINK 4' 1 180 1999 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. C Copyright 2019 Saint Lucie County Property Appraiser. All rights reserved_