Loading...
HomeMy WebLinkAboutProduct Approval RE w of Authorization No.29824 CREEK c 17520 Edinburgh Dr CODE COMPLIANCE Tampa,FL 33647 TECHNICAL SERVICES9S:r_tq.UC ® (813)480-3421 EVALUATION REPORT � DA UILD NG CODE 6T"EDITION(2017) Manufacturer: BORAL ROOFING LLC Issued February 19, 2019 7575 Irvine Center Drive RECEIVED Irvine, CA 92618 (800)669-8453 www.boralamedca.com JUL 0 2 2019 Manufacturing Plants: Lake Wales, FL ST. Lucie County, Permitting Okeechobee, FL Quality Assurance: PRI Construction Materials Technologies(QUA9110) SCOPE Category: Roofing Subcategory: Roofing Tiles Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Properties: Physical Properties,Attachment Requirements,Wind Driven Rain, Static Uplift Resistance REFERENCES Enifty Report No. Standard Year American Test Lab of South Florida Inc(TST3782) RT0201.01-19 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0130.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0426.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0615.02-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0615.03-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0615.04-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0617.02-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0617.03-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0617.04-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0623.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0624.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT0624.05-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT1210.02-15 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc(TST3782) RT1210.03-15 TAS 112 1995 ASTM C 1492 2003(2009) Miami-Dade BCCO(CER1592) 14-0408.06 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 14-0416.12 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 15-0721.04 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 16-0112.07 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 16-0112.08 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 18-0509.15 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 18-0509.16 FBC(HVHZ) 2017 Miami-Dade BCCO(CER1592) 18-0509.17 FBC(HVHZ) 2017 BOR18003.1 FL28328-R7 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product.changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Enti Report No. Standard Year Tile Roof Institute Membership Confirmation TAS 100 1995 TAS 101 1995 TAS 102&102(A) 1995 BOR18003.1 FL28328-R1 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEKREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Bermuda (Okeechobee) Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof file Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 16"x 10" � 16' 1-1/4' 7111 10' f �R 10' Figure 1. Bermuda Plantation (Okeechobee) Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1/2"x 13" 16-1/2,, Figure 2. Plantation BOR18003.1 FI-28328-RI Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Saxony 900 Slate, Shake and Split Shake(Lake Wales and Okeechobee) Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof file Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 17"x 13"x 1-5/32"(Slate)or 1-9/32"(Shake and Split Shake) NAIL HOLES ► 1-5/32"(Slate) 17" COVERLOCK 13" UNDERLOCK Figure 3. Saxony 900 Slate NAIL HOLES 1.9/32'.(Shake) 17" 13" Figure 4.Saxony 900 Shake NAIL HOLES \\ e \�\ 1-9/32"(Shal.-e) 17" 13" Figure 5.Saxony 900 Split Shake BOR18003.1 FL28328-R1 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Estate "S" (Okeechobee) Profile/Description: ASTM C 1492,TAS 112 Type 1 b, low profile, interlocking,class III concrete roof tile Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1/2"x 13" Nail Holes 161/2, 13 Figure 6. Estate Villa 900 (Lake Wales) Profile/Description: ASTM C 1492,TAS 112 Type 1b, low profile, interlocking, class III concrete roof file Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 17.0"x 13"x 2-1/8" Nail holes .12" 1„ �) �—11/2° B Overlock 21/8" 17" j Underlock 13" Figure 7.Villa 900 BOR18003.1 FL28328-R1 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Barcelona 900 (Lake Wales) Profile/Description: ASTM C 1492,TAS 112 Type 1a, high profile, interlocking, class III, 'S'shaped concrete roof tile Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 17"x 13"x 3-5/8" NAIL HOLES OVERLOCK 3.518° 17" 13" LINDERLOCK Figure 8. Barcelona 900 Galena Spanish "S" (Okeechobee) Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile, interlocking,class III 'S'shaped concrete roof tile Allowable Applications: For mechanically fastened(direct deck), mortar set or adhesive set applications Dimensions: 17"x 10"x 2.7" Fastener Holes 17" 10" Figure 9. Galena Spanish "S" BOR18003.1 FL28328-R1 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES,LLC Spanish "S" Nuevo (Lake Wales) Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile,interlocking, class III 'S'shaped concrete roof the Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications Dimensions: 17"x 9-3/4"x 2-27/32" Fastener Holes 17" 9-3/4" Figure 10.Spanish "S" Nuevo APPLICATION METHOD Installation Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as applicable. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max.24 in.span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. 24 in.span; Designed by others in accordance with FBC requirements. Underlaym mt: Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment shall be installed as described in RAS 118, RAS 119,or RAS 120,as applicable. BOR18003.1 FL28328-R1 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC 'Data for Attachment=Calculations,for Direct to Deck ApPlications Aerodynamic Restonn Moments due toGravi M ft Ib Nominal Weight(W)and:; Multipliers g tY < s( fl. Dimensions(I;x w) 3 Direct Deck. Roof Tile' A(ft). Direct Deck W(Ibf) I(ft). w(ft) Application 3 12 , 4:12 5':12" 6;1'2" >7":12" Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35 Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04 Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95 Estate"S" 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14 Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95 Barcelona 11.5 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42 900 Galena 8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57 -Spanish"S' Spanish"S" 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39 Nuevo Data for'Attachment Calculations-for Batten Applications Aerodynamic Nominal Weight(W)and Restoting,Moments;due'to Gravity-M9(ft-IbD . Dimensions(I x w) Multipliers.. Direct.Deck :Roof Tile.. A(ft) Batten W(Ibf) ,•I(ft) ,'• w(ft) Application 3 12 4°:12 5" 12 6 12 >7":12° Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97 Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26 Saxony 900 .10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13 Estate"S" 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40 Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08 Barcelona 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76 900 Spanish"S° 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82 Nuevo BOR18003.1 FL28328-R1 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. BOR AL D E E K AL ROOFING LLC j� Concrete Roof Tiles TECHNICAL SERVICES,LLC Attachment Resistance Expressed as a Moment for Mechanically Fasteneii Applications, TileFastener Mf'(ft-Ibf1 -Roof Tii6 :• girect Deck Drecfbeck_ . Type; Count :: :Size Shank Chp (min..15/32 (rnm.;,19132 Battens plywood) plywood) Nail 2 10d Ring N/A 30.9 38.1 17.2 Nail 1 10d Smooth N/A 7.3 9.8 4.9 or Screw Nail 2 10d Smooth N/A 14.0 18.8 7.4 or Screw Screw 1 #8 N/A N/A 30.8 30.8 18.2 B Screw 2 #8 N/A N/A 51.7 r 51.7 .4 Plantation or Saxony 900 Nail 1 10d Smooth or Screw Field i 24.3 24.3 24.2 Nail 1 10d Smooth Eave 19.0 19.0 22.1 or Screw Nail 2 10d Smooth Field 35.5 35.5 34.8 or Screw Nail 2 10d Smooth Eave 31.9 31.9 32.2 or Screw Nail' 2 10d Ring N/A 50.3 65.5 48.3 Nail 2 10d Ring N/A 27.8 37.4 28.8 Nail 1 10d Smooth N/A 8.8 11.8 4.1 or Screw Nail 2 10d Smooth N/A 16.4 21.9 7.1 or Screw Screw 1 #8 N/A N/A 25.8 25.8 22.9 Estate ,S"Z' Screw 2 #8 N/A N/A 47.1 47.1 49.1 Villa 900 Nail 1 10d Smooth Field 2,4.3 24.3 24.2 or Screw Nail 1 10d Smooth Eave 19.0 19.0 22.1 or Screw Nail 2 10d Smooth Field 35.5 35.5 34.8 or Screw Nail 2 10d Smooth Eave 31.9 31.9 32.2 or Screw Estate"S" Nail' 2 10d Ring N/A 43.0 67.5 50.9 i i Continued on following page j BOR18003.1 FL28328-R1 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Attachment Resistance Expressed as a Momenf for Mechanically Fastened Applications ns _ Tile Fastener Mr(ft-lbf) Roof Tile :Direct Deck' Direct Deck., Type', Count Size Shank Chp " '(.min..15/32° (min: 19/32 Battens plywood) plywood) - Nail 2 10d Ring N/A 28.6 41.2 19.4 Nail 1 10d Smooth N/A 5.1 6.8 2.8 or Screw Nail 2 10d Smooth N/A 6.9 9.2 7.3 or Screw Screw 1 #8 N/A N/A 20.7 20.7 18.1 Barcelona 900, Screw 2 #8 N/A N/A 43.2 43.2 29.8 Galena or Spanish"S" Nail 1 10d Smooth Field . 23.1 23.1 19.0 Nuevo or Screw Nail 1 10d Smooth Eave 29.3 29.3 24.0 or Screw Nail 2 10d Smooth Field 27.6 27.6 38.6 or Screw Nail 2 10d Smooth Eave 38.1 38.1 41.8 or Screw Nail' 2 10d Ring N/A 33.1 48.1 45.2 Notes: 1)Not for Saxony 900,Villa 900 or Barcelona 900. Installation with a 4"tile headlap and fasteners are located a min.2-1/2" from head of tile. 2)When using only one fastener,use the hole that is approximately 4-3/4"away from interlocking edge. 3)Direct Deck applications only. Attachment Resistance.-Expressed as a.Moment for,Adhesive or.'M&tarSef-- Roof Tile Adhesive':-,'.".,,.,."" Product-Approval-a'-.1' Faddy Average Paddy. Mr.(ft-lbf) . Count . .:Weight(grams) Dow Chemical TILE BONDTm NOA 16-0222.01 2 13.9 31.3 Bermuda, 2 8 31.3 Planation and Saxony 900 ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 40.4 1 45 118.9 DAP Foam Inc.Touch N'Seal® 2 8 59.0 NOA 17-082912 1 24 45 Saxony 900 Storm BondTm 2 Two-Component . 1 45 93 Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 43.9 Dow Chemical TILE BOND rm NOA 16-0222.01 2 11.4 26.1 2 8 26.1 Estate"S"or ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5 Villa 900 1 54 86.61 Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 20.6 2 8 55 Villa 900 DAP Foam Inc.Touch N'Seal® NOA 17-0829.12 1 30 40 Storm BondTm 2 Two-Component 1 60 70 BOR18003.1 FL28328-R1 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Attachment Resistance Expressed as•a Moment forAdheslve or Mortar'Sef Roof Tile Adhesive Product Approval' ;5 Paddy Average Paddy Mr.(ft-lbf) Count. ..Weight{grams) Dow Chemical TILE BONDTm NOA 16-0222.01 2 10.7 29.3 Barcelona 900, 2 8 29.3 Galena Spanish ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7 "S"or Spanish "S"Nuevo 1 63 66.5 Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 24.5 2 8 66.0 DAP Foam Inc.Touch N'Seal® Barcelona 900 NOA 17-0829.12 1 30 63 Storm BondTm 2 Two-Component 1 60 82 Notes: 1)See manufacturer's product approval for installation requirements. LABELING 1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows: Manufactured in Lake Wales, FL Manufactured in Okeechobee, FL OR ENT RR BOR18003.1 FL28328-R1 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. BOR AL Y AL ROOFING LLC CREEK D 1E" 1.." I 1 Concrete Roof Tiles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAITRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120. 3) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. 4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A. 5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50 or greater as illustrated in ASTM C 1492-03,figure 1 (see below). 50 50 5o WEATHERING REGIONS NEGLIGIBLE WEATHERING WEATHERING i MODERATE WEATHERING SEVERE WEATHERING '+ COMPLIANCE STATEMENT The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building Code,6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ,` 1tJ1111u1111ii, P�� N•'° 2019.02.1 910:10:22 No 74021 � AWMYMO+�I�wYn :CC:CCZ 5'00' 13••. STATE OF 0.����`�;• O R �•• G��.` Zachary R. Priest, P.E. l t� Organization No.Florida Registratl on ANE9641021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT BOR18003.1 FL28328-R1 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.