HomeMy WebLinkAboutProduct Approval RE w of Authorization No.29824
CREEK c 17520 Edinburgh Dr
CODE COMPLIANCE Tampa,FL 33647
TECHNICAL SERVICES9S:r_tq.UC ® (813)480-3421
EVALUATION REPORT � DA UILD NG CODE 6T"EDITION(2017)
Manufacturer: BORAL ROOFING LLC Issued February 19, 2019
7575 Irvine Center Drive RECEIVED
Irvine, CA 92618
(800)669-8453
www.boralamedca.com JUL 0 2 2019
Manufacturing Plants: Lake Wales, FL ST. Lucie County, Permitting
Okeechobee, FL
Quality Assurance: PRI Construction Materials Technologies(QUA9110)
SCOPE
Category: Roofing
Subcategory: Roofing Tiles
Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3
Properties: Physical Properties,Attachment Requirements,Wind Driven Rain, Static Uplift
Resistance
REFERENCES
Enifty Report No. Standard Year
American Test Lab of South Florida Inc(TST3782) RT0201.01-19 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0130.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0426.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.02-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.03-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.04-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.02-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.03-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.04-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0623.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0624.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0624.05-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT1210.02-15 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT1210.03-15 TAS 112 1995
ASTM C 1492 2003(2009)
Miami-Dade BCCO(CER1592) 14-0408.06 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 14-0416.12 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 15-0721.04 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 16-0112.07 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 16-0112.08 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.15 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.16 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.17 FBC(HVHZ) 2017
BOR18003.1 FL28328-R7 Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product.changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Enti Report No. Standard Year
Tile Roof Institute Membership Confirmation TAS 100 1995
TAS 101 1995
TAS 102&102(A) 1995
BOR18003.1 FL28328-R1 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEKREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 16"x 10"
� 16'
1-1/4'
7111
10'
f
�R
10'
Figure 1. Bermuda
Plantation (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2"x 13"
16-1/2,,
Figure 2. Plantation
BOR18003.1 FI-28328-RI Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Saxony 900 Slate, Shake and Split Shake(Lake Wales and Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 17"x 13"x 1-5/32"(Slate)or 1-9/32"(Shake and Split Shake)
NAIL HOLES ►
1-5/32"(Slate)
17" COVERLOCK
13"
UNDERLOCK
Figure 3. Saxony 900 Slate
NAIL HOLES
1.9/32'.(Shake)
17"
13"
Figure 4.Saxony 900 Shake
NAIL HOLES \\
e
\�\ 1-9/32"(Shal.-e)
17" 13"
Figure 5.Saxony 900 Split Shake
BOR18003.1 FL28328-R1 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Estate "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 1 b, low profile, interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2"x 13"
Nail Holes
161/2,
13
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 1b, low profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 17.0"x 13"x 2-1/8"
Nail holes
.12"
1„ �) �—11/2°
B
Overlock
21/8"
17" j
Underlock
13"
Figure 7.Villa 900
BOR18003.1 FL28328-R1 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Barcelona 900 (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 1a, high profile, interlocking, class III, 'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 17"x 13"x 3-5/8"
NAIL HOLES
OVERLOCK
3.518°
17"
13"
LINDERLOCK
Figure 8. Barcelona 900
Galena Spanish "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile, interlocking,class III 'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened(direct deck), mortar set or adhesive set applications
Dimensions: 17"x 10"x 2.7"
Fastener Holes
17"
10"
Figure 9. Galena Spanish "S"
BOR18003.1 FL28328-R1 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES,LLC
Spanish "S" Nuevo (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile,interlocking, class III 'S'shaped concrete
roof the
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 17"x 9-3/4"x 2-27/32"
Fastener Holes
17"
9-3/4"
Figure 10.Spanish "S" Nuevo
APPLICATION METHOD
Installation
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck: at max.24 in.span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in.span; Designed by others in accordance with FBC requirements.
Underlaym mt: Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
shall be installed as described in RAS 118, RAS 119,or RAS 120,as applicable.
BOR18003.1 FL28328-R1 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
'Data for Attachment=Calculations,for Direct to Deck ApPlications
Aerodynamic Restonn Moments due toGravi M ft Ib
Nominal Weight(W)and:; Multipliers g tY < s( fl.
Dimensions(I;x w) 3 Direct Deck.
Roof Tile' A(ft).
Direct Deck
W(Ibf) I(ft). w(ft) Application 3 12 , 4:12 5':12" 6;1'2" >7":12"
Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35
Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04
Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95
Estate"S" 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14
Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95
Barcelona 11.5 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42
900
Galena 8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57
-Spanish"S'
Spanish"S" 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39
Nuevo
Data for'Attachment Calculations-for Batten Applications
Aerodynamic
Nominal Weight(W)and Restoting,Moments;due'to Gravity-M9(ft-IbD .
Dimensions(I x w)
Multipliers.. Direct.Deck
:Roof Tile.. A(ft)
Batten
W(Ibf) ,•I(ft) ,'• w(ft) Application 3 12 4°:12 5" 12 6 12 >7":12°
Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97
Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26
Saxony 900 .10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13
Estate"S" 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40
Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08
Barcelona 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76
900
Spanish"S° 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82
Nuevo
BOR18003.1 FL28328-R1 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
BOR
AL D E E K AL ROOFING LLC
j� Concrete Roof Tiles
TECHNICAL SERVICES,LLC
Attachment Resistance Expressed as a Moment for Mechanically Fasteneii Applications,
TileFastener Mf'(ft-Ibf1
-Roof Tii6 :• girect Deck Drecfbeck_ .
Type; Count :: :Size Shank Chp (min..15/32 (rnm.;,19132 Battens
plywood) plywood)
Nail 2 10d Ring N/A 30.9 38.1 17.2
Nail 1 10d Smooth N/A 7.3 9.8 4.9
or Screw
Nail 2 10d Smooth N/A 14.0 18.8 7.4
or Screw
Screw 1 #8 N/A N/A 30.8 30.8 18.2
B Screw 2 #8 N/A N/A 51.7 r 51.7 .4
Plantation or
Saxony 900 Nail 1 10d Smooth or Screw Field i 24.3 24.3 24.2
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth Field 35.5 35.5 34.8
or Screw
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Nail' 2 10d Ring N/A 50.3 65.5 48.3
Nail 2 10d Ring N/A 27.8 37.4 28.8
Nail 1 10d Smooth N/A 8.8 11.8 4.1
or Screw
Nail 2 10d Smooth N/A 16.4 21.9 7.1
or Screw
Screw 1 #8 N/A N/A 25.8 25.8 22.9
Estate ,S"Z' Screw 2 #8 N/A N/A 47.1 47.1 49.1
Villa 900
Nail 1 10d Smooth Field 2,4.3 24.3 24.2
or Screw
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth Field 35.5 35.5 34.8
or Screw
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Estate"S" Nail' 2 10d Ring N/A 43.0 67.5 50.9
i
i
Continued on following page j
BOR18003.1 FL28328-R1 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Attachment Resistance Expressed as a Momenf for Mechanically Fastened Applications
ns _
Tile Fastener Mr(ft-lbf)
Roof Tile :Direct Deck' Direct Deck.,
Type', Count Size Shank Chp " '(.min..15/32° (min: 19/32 Battens
plywood) plywood) -
Nail 2 10d Ring N/A 28.6 41.2 19.4
Nail 1 10d Smooth N/A 5.1 6.8 2.8
or Screw
Nail 2 10d Smooth N/A 6.9 9.2 7.3
or Screw
Screw 1 #8 N/A N/A 20.7 20.7 18.1
Barcelona 900, Screw 2 #8 N/A N/A 43.2 43.2 29.8
Galena or
Spanish"S" Nail 1 10d Smooth Field . 23.1 23.1 19.0
Nuevo or Screw
Nail 1 10d Smooth Eave 29.3 29.3 24.0
or Screw
Nail 2 10d Smooth Field 27.6 27.6 38.6
or Screw
Nail 2 10d Smooth Eave 38.1 38.1 41.8
or Screw
Nail' 2 10d Ring N/A 33.1 48.1 45.2
Notes: 1)Not for Saxony 900,Villa 900 or Barcelona 900. Installation with a 4"tile headlap and fasteners are located a min.2-1/2"
from head of tile.
2)When using only one fastener,use the hole that is approximately 4-3/4"away from interlocking edge.
3)Direct Deck applications only.
Attachment Resistance.-Expressed as a.Moment for,Adhesive or.'M&tarSef--
Roof Tile Adhesive':-,'.".,,.,."" Product-Approval-a'-.1' Faddy Average Paddy. Mr.(ft-lbf) .
Count . .:Weight(grams)
Dow Chemical TILE BONDTm NOA 16-0222.01 2 13.9 31.3
Bermuda, 2 8 31.3
Planation and
Saxony 900 ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 40.4
1 45 118.9
DAP Foam Inc.Touch N'Seal® 2 8 59.0
NOA 17-082912 1 24 45
Saxony 900 Storm BondTm 2 Two-Component .
1 45 93
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 43.9
Dow Chemical TILE BOND rm NOA 16-0222.01 2 11.4 26.1
2 8 26.1
Estate"S"or ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5
Villa 900
1 54 86.61
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 20.6
2 8 55
Villa 900 DAP Foam Inc.Touch N'Seal® NOA 17-0829.12 1 30 40
Storm BondTm 2 Two-Component
1 60 70
BOR18003.1 FL28328-R1 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Attachment Resistance Expressed as•a Moment forAdheslve or Mortar'Sef
Roof Tile Adhesive Product Approval' ;5 Paddy Average Paddy Mr.(ft-lbf)
Count. ..Weight{grams)
Dow Chemical TILE BONDTm NOA 16-0222.01 2 10.7 29.3
Barcelona 900, 2 8 29.3
Galena Spanish ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7
"S"or Spanish
"S"Nuevo 1 63 66.5
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 24.5
2 8 66.0
DAP Foam Inc.Touch N'Seal®
Barcelona 900 NOA 17-0829.12 1 30 63
Storm BondTm 2 Two-Component
1 60 82
Notes: 1)See manufacturer's product approval for installation requirements.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in Lake Wales, FL
Manufactured in Okeechobee, FL
OR
ENT RR
BOR18003.1 FL28328-R1 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
BOR
AL Y AL ROOFING LLC
CREEK D 1E" 1.." I 1 Concrete Roof Tiles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAITRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120.
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03,figure 1 (see below).
50
50 5o
WEATHERING REGIONS
NEGLIGIBLE WEATHERING
WEATHERING i
MODERATE WEATHERING
SEVERE WEATHERING '+
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
Code,6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
,` 1tJ1111u1111ii,
P�� N•'° 2019.02.1
910:10:22
No 74021
� AWMYMO+�I�wYn
:CC:CCZ 5'00'
13••. STATE OF
0.����`�;• O R �•• G��.` Zachary R. Priest, P.E.
l t� Organization No.Florida Registratl on ANE9641021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
BOR18003.1 FL28328-R1 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.