Loading...
HomeMy WebLinkAboutProduct Approval (2) 1_kM1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION ° 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURC i �E�pg E® FOR Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION86)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA ®®� C ®��L0�1Nwmv.miamidade. ov/econom ICP Adhesives and Sealants,Inc. ° LUCIE COUP" 12505 NW 441h Street MCC Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.. DESCRIPTION: ICP Adhesives Polyset®AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 MIAMMADE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described in this Notice of Acceptance.For the locations where the design pressure requirements, as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP Adhesives Polyset®AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPacO N/A Dispensing Equipment 30& 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Prope Test Results Density ASTM D 1622 1.61bs./ft 3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 . +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Mu►t�Noane couNrr Expiration Date: 05/10/22 Approval Date:04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset®AH-160 shall solely be used with flat,low, &high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset"AH-160 maybe used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset®AH-160. 2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and TCP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants,Inc.ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B" component shall be maintained between 1.0-1.15 (A): 1.0(B). 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack®30& 100 dispensing equipment only. 7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset®AH-160 has been dispensed. 9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 MIAMI•nADe CO Expiration Date: 05/10/22 Approval Date:04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low,High Profiles #1 17-23 sq.inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel(Pan Tile) j Two Piece 1 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. P°1a�91�AL]E�QUIM[7?f BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# I mathroughplastitcement Paddy(Benoaal►ra°) Flat/Low Profile Tile lghsnroquired) undpa.ymen: 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam - paddy onto the underlayment positioned as shown, 4 under the strengthening rib closest to the overlock 101n. ti ,f?: of the tile being set. 51 Wttcnsoptionat l 2. Continue in same manner.Insure approximately 17 EavcCoussr ° (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. Fascia Emtlosun � ! Medium Profile/ Double Pan Tile Mail through plastic cement (when reatdred) Prddy,Ernrr[fiTe1r] 1. Starting at the eave course,apply a minimum 2" Undeslryt tt ` N (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown fes. under the pan portion of the tile closest to the overlock of the tile being set. 10in 21r.wl 14 -.�' ,, �..,. 2. Continue in same manner.Insure approximately 17 9attensool al �4t. (109.7 cm2)—23 (148.4 cm2)square inch adhesive �```�ti`t a✓ contact with the underside of the tile. loth_ tin. �-Favo closure Eavecourso Fascia Nall 4hmughPlr►tleurarri High Profile/Single Pan Tile l►�h°n requtratil} Paddy IBanra[hT)lel 1. Starting at the eave course,apply a minimum 2" �u (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the a m.".da ,? overlock of the tile being set. Battens, 2. Continue in same manner.Insure approximately 17 �' nptbonal t '_, -` (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. P. Eaveraursa `r� y FiSGa * . Weephote IpEmr closure ,rr NOA No.: 17-0322.03 MAMI•DAD;COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL.#2 NA through p1,4u1ccvma"1 Nddyl6envathWO Flat/Low Profile Tile (ttf+en required) Urdordiyn:an: "f 1. Starting at the eave course,apply a minimum 2"(50.8 o mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of 2M, � ` the tile being set.Insure approximately 17(109.7 cm2) 23 (148.4 cm2)square inch adhesive contact with the UW CourWA underside of the tile. ` 2. At the second course,apply a minimum 2"(50.8mm) Fascia x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile Ericclosure---- being set. 3. Continue in same manner.Insure approximately 10" (64.5 cm2)- 12(77.4 cm2)square inch adhesive contact with the underside of the tile. Nail through plastic cement Medium Profile/Double Pan Tile twhen►equiredl Paddy fBeneathTile) 1. Starting at the eave course,apply a minimum 2"(50.8 Und*vI'Ayr"\-.' 6 -'� mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the Overlock of the tile being set.Insure approximately 17(109.7 cm2)— 'Iy�2 in. ~� , � '.`,, 23 (148.4 cm2)square inch adhesive contact with the Battens optional , underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) �0Imn 2 x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the FAv*Q,",,, underlayment positioned as shown under the pan Eave County tr Fascia portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm2)square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 MIAMI•DAD'COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 —ADHESIVE PLACEMENT DETAIL##2 (CONTINUED) Mal through pluukce etst pasldyfBenra�hlil•J High Profile/Single Pan Tile dwhcn ecqulred) vnd#iUyrnen% 1. Starting at the eave course,apply a minimum 2"(50.8 • •", mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy �`` •' onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17(109.7 cm2)— 7`" film. ti ~ 23 (148.4 cm2)square inch adhesive contact with the eattcnsapaons) iti:' underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) T Enwe ase faxie x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the IV. ' underlayment positioned as shown under the pan loin, Z In, portion of the tile closest to the overlock of the tile Drlpedge being set. 3. Continue in same manner.Insure approximately 17" (109.7 cm2)- 19 (122.6 cm2)square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 t t Approval Date:04/27/17 Page 8of11 ADHESIVE PLACEMENT DETAIL#3 hai[tluoughplasticcement Paddy(betweentues) Iwhenrequirea) 1. On the eave course only,apply a minimum 2" (50.8 Battensoptional ° mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy ° Pad dy(under tile) onto the underlayment positioned as shown,under single paddy the strengthening rib for flat tile or under the pan Y ontopoftile w r portion of the tile for low or high profile tile closest to the overlock of the tile being set.Leave �Z4x41nSin giepaad `-- `ti ' approximately 4" (10 1.6 mm)up from the eave Scngiepaddy un ert, ,�`` �� edge free of foam to prevent the expanded adhesive on underlayment ° 2x41n. �= from blocking the weep holes. Insure ,F _�.t approximately 17-23 in2(109.7-148.4 cm2)of to in :�, adhesive contact with the underside of the tile `t2 in. Faveclosure 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4 mm)foam paddy onto the underlayment just below Flat/Low Profile Tile the second course line positioned foam paddy under the strengthening rib for flat tile, or under the Nall through plastic cement Single paddy under tile pan portion of the tile,closest to the underlock for (when required) Paddy{between tiles) the second course tile to be installed. Insure approximately 8-9 int(51.6-58.1 cm2)of adhesive Battens Paddy(undertiile) contact with the underside of the tile. optional -t O9 Y Smglepaddy ontopattae ._`'--,? (Instructions continued on nextpage) �4 coin. :4in�- ^'"•, , Single paddy on ' undedayment <2 10u1. N `2 in. •b Eave Closure Eave Course Fascia Medium ProflleTlle NOA No.: 17-0322.03 MIAMI-DAD,COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) Haiilthroughplasticce Single paddy under tile(when required) 3. Also apply a 2" (50.8 mm)x 4"(101.6 mm)x 3/a" Paddy(between tiles) (19 mm)paddy on top of the eave course tile Battens `* Paddy surface as shown, on top of the strengthening rib optional for flat tile or on top of the pan portion of the tile, 6 closest to the underlock of the first course of tile. ona�neda ymen _ + Install second course of tile.Insure approximately axain. �, 9(58.1 cm')- 11 (71cm2)square inch adhesive contact with the underside of the tile at the overlap Single 2x41n. '• .� and 7(45.2 cm2)-9(58.1 cmZ)square inch top o tie adhesive contact with the underside of the tile at '`• the head of the tile.Continue in same manner. EaveCourse Fasda Weephole Loin. 2in. Eave closure Dripedge High Proli(eT((e NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 r Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile 1. Starting at the eave course,apply a minimum 2" in cPlace ontact with enough adhesive 4o achieve 65 to.70 sq.in: Steep pitch applications (/50.8 mm x 10"/254 mm x 1"/25.4 mm foam in contactwith the pan tile. (when required) l ) l ) l ) 2)Tum covers upside down.Place adhesive in paddy onto the underlayment positioned as .tol In.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave Then install the til@:Ensure 20 to 25 sq.in.contact area. - ° tiles from rocking until adhesive has a chance to Underlayment C- -';1- Cure. 2. Continue in same manner bringing two pan r �= courses up toward the ridge.Insure approximately 65 419.4 cm2 —70 451.6 cm2 square inch adhesive contact with the underside of the pan tile. �- Sheathing Eaveciosure (motarshown) 3. Turn covers upside down exposing the underside weephole Fascia Board of the tile.Apply a minimum 1"(25.4 mm)x 10" (254 mm)bead of adhesive directly on the inner Remove top portion of the eave course cover tile.Abut to second course of edge of each side of the cover tile.Leave pantiles.Ensure eave end ofpan and cover tiles are flush at eave line. approximately 3/4"(19 mm)to 1"(25.4 mm) Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20(129 cm2)-25 (161.3 cm2)square inch contact area on each side of the cover tile to the pan tile.Continue in same manner. Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required,2"(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized, stainless steel,or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 r Approval Date:04/27/17 Page 11 of 11