HomeMy WebLinkAboutProduct Approval (3) REVIEWED FOR NEMO I etc. (00®F C;(oMPLIANCE Certificate of Authorization#32455 353 Christian Street, Unit#13 LUCIE COUNTY Oxford, CT 06478 Bona (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION ICP Adhesives and Sealants,Inc. Evaluation Report 02768.02.06-117 12505 NW 44th Street FL6276-117 Coral Springs, FL 33065 Date of Issuance:03/21/2006 (888)774-1419 Revision 7:08/15/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert.Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 61h Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset®RTA-1 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation changes. MEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words"NEMO ETC,LLC Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen P.E. The facsimile seal appearing was authorized by Robert ••J� s Nieminen,P.E.on 08/15/2018.This does not serve as an Florida Registration No.59166,Florida DC4ANE1983 ` c°di�;;;i�a �� electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roof Tile Adhesive Compliance Statement: ICP Adhesives Polyset® RTA-1, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition(2017)Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Static Uplift—SSTD 11 E42730.08.13 08/23/2013 ERD(TST6049) Static Uplift—SSTD 11 ECM-SC6795.12.14-2 02/27/2015 Miami-Dade(CER 1592) HVHZ compliance 18-0131.02 07/12/2018 NEMO(TST6049) Static Uplift—SSTD 11 4L-ICP-18-001.05.18-1 05/15/2018 NEMO(TST6049) Tensile Adhesion/Underlayments 4S-ICP-18-001.07.18 07/23/2018 PRI(TST5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI(TST5878) Static Uplift—SSTD 11 PFI-008-02-03 12/14/2005 PRI(TST5878) Static Uplift—SSTD 11 PFI-008-02-04 12/14/2005 PRI(TST5878) Static Uplift—SSTD 11 FOP-009-02-05 Rev2 06/01/2015 UL,LLC.(QUA9625) Quality Assurance Service Confirmation 02/07/2018 PRODUCT4. DESCRIPTION: 4.1 ICP Adhesives Polyset®RTA-1 is a single component polyurethane foam roof tile adhesive distributed in factory,pre- mixed canisters. LIMITATIONS:5. 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® RTA-1 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local-level by the Authority Having Jurisdiction. 5.5 Underlayment shall be per FRSA/TRI April 2012 (04-12)or having a current Florida Statewide Product Approval or approved on a local-level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset®RTA-1. 5.6 Field tiles,meeting the limitations of FBC 1609.5.3,using ICP Adhesives Polyset®RTA-1 are limited to projects having an Aerodynamic Uplift Moment(Ma),determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12),not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants,Inc.published installation instructions for Adhesive Paddy Placement details. MEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-117 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 2 of 8 ONEMOletc.-_ TABLE 1:FIELD TILES IN ICP ADHESIVES PoLysETO RTA-1 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA 4 To 1 MARGIN OF SAFETY ALREADY AP LIED Tile(FBC 1609.5.3) Adhesive Paddy Placement allowable Overturning Type Profile Pad Size/Contact Area Paddy Detail, Moment Section 10 (ft-lbf) Interdependent Two Paddy;two(2)ribbons,11 grams each Clay or Flat Low Install the and ensure 8-10 square inch contact area to underside of tile. #1 50 Concrete / Ensure adhesive is making 10 square inch contact area at the tile head lap area Interdependent Two Paddy;two(2)ribbons,it grams each Concrete Medium Install tile and ensure 6-8 square inch contact area to underside of tile.Ensure #2 44 adhesive is making 10 square inch contact area at the the head lap area. Clay High Interdependent Two Paddy;two(2)ribbons 36 • 22 grams tail-to-substrate • 11 grams at head-lap #3 Install tile and ensure 12-16 square inch contact area to underside of tile. Concrete High Ensure adhesive is making 18 square inch contact area at the tile head lap 33 area. Pan Tile to Underlavment: Two(2)—7-inch long x—6 gram oblong shaped beads on underlayment,side-by-side,where the center of the pan tile contacts the deck starting^2 to 3-inches from the eave end of the pan tile Cap&Pan Cap Tile to Pan Tile:One(1)—7-inch long x—6 gram oblong shaped bead at Clay (Barrel) each long edge of the cap tile,%to 1-inch from each edge,starting^2 to 3- #4 162 inches from the eave end working towards the ridge. Turn cap tile over and install onto pan,butting the second course pan tile eave end on underlayment,side-by-side,where the center of the pan tile contacts the deck starting^2 to 3-inches from the eave end of the pan tile. 5.6.1 Data in Table 1 relates to installation over a'30/90'underlayment system,as detailed in the FRSA/TRI April 2012(04- 12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local-level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset®RTA-1. 5.6.2 Tile roof systems using the types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset®RTA-1 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi-paddy method, an additional 2-to-1 margin of safety above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the'allowable overturning moment'. 5.7 Hip and ridge tiles using ICP Adhesives Polyset® RTA-1 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. NEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-R7 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 3 of 8 NNEMO I etc. RIDGE ADHESIVES . c . a ALLOWABLE O. ALREADY2 To 1 MARGIN OF SAFETY I FOR INDEPENDENT ALREADY4 To 1 MARGIN OF SAFETY I FOR INTERDEPENDENT Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay or Interdependent:Head:One(1)#10 x 2%"screw; Concrete 2x PT ridge board Overlap:1x6-inch x—10.5 gram 187 See Section 10,Placement Detail#5 Hip&Ridge Channel Metal(FBC FL5374): Independent:Tile-to-metal,centered along tile:3x6- Concrete galvanized only inch x"30 gram,starting 3-inch from the tile head. 123 See Section 10,Placement Detail#6 Hip&Ridge Channel Metal(FBC FL5374): Independent:Tile-to-metal,centered along tile:3x6- Clay galvanized only inch x—30 gram,starting 4-inch from the tile head. 251 See Section 10,Placement Detail#6 Trim LockT (FBC FL5394):aluminum Interdependent: Clay or or On Trim-Lock''metal:One(1)^'7-inch long x-10 gram 93 Concrete Trim LockT Plus(FBC FL5394):aluminum, oblong shaped paddy centered on metal. galvanized,Galvalume®or stainless steel At Tile Headlap:One(1)—7-inch long x~10 gram Clay or Trim Lock—(FBC FL5394):galvanized, oblong shaped bead at tile headlap. 110 Concrete Galvalume®or stainless steel See Section 10,Placement Detail#7. 6. INSTALLATION' 6.1 ICP Adhesives Polyset®RTA-1 and the the roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12)and ICP Adhesives and Sealants,Inc.published installation instructions,subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants,Inc. 6.4 All tiles must be set in adhesive prior to tack free time(approximately 2 to 3 minutes). REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS' Norton,OH 9. QUALITY ASSURANCE ENTITY: UL,LLC.-QUA9625;(847)664-3623;LeAnna.Gradecki@ul.com MEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-R7 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 4 of 8 ONEMO etc. 10. PADDY PLACEMENT DETAILS(FROM ICP ADHESIVES AND SEALANTS,INC.PUBLISHED LITERATURE): 10.1 Detail#1: Flat.Profile Tile: Strengthening Ribs Underside Of Tile Paddy on Deck Dispensed' Horizontally at Tile Course Line a. Pad on Top of Tile _." ._ - Dispensed Horizontally� at Head Lep Underlock mss`.•----y- _ _ . Eave Course Line Overlock Eave Closure Start Eave Course Paddies at Tile Course Line 10.2 Detail#2:Low/Medium Profile Tile: Pan of Tile Paddy on Top of the Tile Dispensed Horizontally at Head Lap Undedock I .� r �'_ �� .t Overlock Eave Course Line . Eave Closure Start Eave Course Paddies at Tile Course Line NEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authodiation#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-R7 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 5 of 8 ONEMOjetc. 10.3 Detail#3:High Profile Tile: Pan of Tile Paddy on Top of Tile Dispensed Horizontally - ''• at Head Lap Eave Course' " ill n i(1 Line _ V 4 _ Eave Closure Start Paddy Underneath Pan Portion of Tile at High Profile Tile Course Line 10.4 Detail#4: Two Piece Barrel(Cap&Pan)Tile: One(1)-7"Paddy w, 4 on each side under ;; cover tiles(Detail) Two(2)-7'Oblong paddies side,by side under pan tiles One(1)-7'Paddy on each side under cover tiles Eave Course Line Eave Closure Two(2)-10"Oblong paddies side by side under pan tiles 2-Piece Barrel Profile leave course only) NEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-R7 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 6 of 8 ONEMOjetc. 10.5 Detail#5: Hip and Ridge(interdependent with screw): 1".)C.5"•Bead•of•iCP- Adhesives*, ' * Polyset°RTA=1-roof- 'I tle•adhesive•• =r k, #10x•2-1/2"•Screw• Code�Approved• Fastener9 Adhere•starter- ti Ie-%vith•a•2"x•7"- Paddyplaced•3 dovJn•fr"om•head- of•tife 10.6 Detail#6: Hip and Ridge(independent placement): 3"x 6"Paddy t7.1 I NEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL6276-R7 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 7 of 8 ONEMOjetc. 10.7 Detail#7: Hip and Ridge(interdependent placement): 7" Oblong Paddy 7" Oblong Paddy i we-is -END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report 02768.02.06-R7 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.6276-117 ICP Adhesives Polyset®RTA-1;(888)774-1419 Revision 7:08/15/2018 Page 8 of 8