Loading...
HomeMy WebLinkAboutWind Load Calculation JUL I. ZOiJ VILE u0py SI.:LUGie County, Permitting -Property Information Building Information Owner: Vinas Wind Zone: 160 MPH. Address: 37 Ipanema Exposure Category: B Ft Pierce,F134951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: H Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 11 1 End 53 55 7 31.0 -40.5 2 Int 25.5 '— 38 7 32.5 -35.2 3 Int 25.5 38 7 32.5 -35.2 4 Int 74 55 7 30.3 -33.0 5 Int _ 72 80 7 29.6 732.3 6 Int 53 55 7 31.0 -33.7 7 Int 53 55 7 31.0 -33.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1