Loading...
HomeMy WebLinkAboutProduct Approval T 3/28/2019 Florida Building Code Online BC1S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search d,b 7 0,t- Product Approval ®�1,;�t- r . USER:Public E® Product Approval Menu>Product or Application Search>epplicatlon List>Application Detail R��1��{GA■ UpAV j4(;e FL17022-R7 cp Out ��c1G Application Type Revision ® • �®cic Code Version 2017 Application Status Approved ®�� File Comments 08/18/2017x.date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 Flvalidation@yahoo.com A/z Authorized Signature Richard McKuhen llb /ttz l)V?0,9 Flvalidation@yahoo.com " o Technical pd corr,7ty enE Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. " Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_Otl.aspx 113 3/28/2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summar of Products 1 FL# Model, Number or Name Description `- -{ 17022.1 1 "5V Crimp"(116) 26 Gauge steel,3/8"rib height, 24"wide lapped roof panel I mechanically attached to 15/32"plywood or Wood Deck with f fasteners i Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No I Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports COther: Refer to evaluation report for/conditions.Install the , FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2- "5V Crimp"(R6) 10.032"Aluminum,3/8"Rib height,21"wide lapped roof panel, 1 i mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use — — I Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3- "1.5"Mechanical Seam" (R5) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions — Approved for use in HVHZ: No I FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ:Yes seam 24 ssrpdf Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly In compliance with the installation I FL17022 R7 AE FL 17022.3 1.5 MECHANICAL method listed in this report and applicable code sections of seam 24ga ssrpdf I FBC. Refer to manufacturer's Installation instructions. 1 Created by Independent Third Party: Yes ) 17022.4 4- "1.5"Mechanical Seam"(R5) 1.5"rib height, 16"wide, 0.032"aluminum,standing seam roof ---�� — -- panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use �I(Installation Instructions Approved for use in HVHZ: No i FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes I ALUMINUM ssrpdf Impact Resistant: No Verified By: Locke Bowden,P.E.49704 i Design Pressure: +N/A/-Table A I Created by Independent Third Party: Yes 1 Other: Refer to evaluation report for conditions and limitations I Evaluation Reports of use.Install the assembly in compliance with the installation j FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM method listed in this report and applicable code sections of ALUMINUM ssrpdf FBC. Refer to manufacturer's installation instructions. _ Created by Independent Third Party: Yes 1-17022.5 — — i 5-"1 in. Nail Strip" (R5)! 1"rib height, 16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck I with fasteners. Limits of Use Installation Instructions— _ -- Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssrpdf t Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf l of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes I II https://www.floridabuilding.org/pr/pr_app_dtl.aspx 213 3/2812019 Florida Building Code Online method listed in this report and applicable code sections of --- — —^^— FBC. Refer to manufacturer's installation instructions. 17022,6 --' 6 "1 in. Nail Strip" (RS) 1"rib height, 16"wide,0.032"aluminum,standing seam roof —^ — panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 1 Approved for use outside HVHZ:Yes ALUM ssr.pdf Impact Resistant: No Verified By: Locke Bowden, RE.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes 1 Other: Refer to evaluation report for conditions and limitations (Evaluation Reports of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 method listed in this report and applicable code sections of ALUM ssr.pdf i FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.7 7-"1.5 in. Nail Strip" (115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Approved for use.outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports. Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 8-"EMAX Rib"(R5) — — 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions j Approved for use in HVHZ: No FL17022 R7 11 FL 177022.8 EMAX Rib ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 177022.8 EMAX Rib ssnpdf of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes method listed in this report and applicable code sections of �FBC. Refer Co manufacturer's installation instructions. 170 22.9 — 9-"PBR MAX" R5 26 au a steel la — MAX" (115) gauge lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use — —� — Installation Instructions --v — Approved for use in HVHZ: No FL17022 R7 11 FL 17022.9 PBR RIB ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf of use.Install the assembly in compliance with the installation Created by Independent Third Party: Yes method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 0 Contact Us::2601 Blair Stone Road,_Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Q=yrlght 2007-2013 State of Florida.::Privacy Statement::Accessibility.Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-pursuant to section 455,275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee,However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: eCrv1 Credit Card Safe i https://www.floridabuilding.org/pr/pr_app_dtl.aspx 3/3 . 4 • ' e • - r a 2160 SW Poma Drive Palm City, FL 34990 1772)872-8034. ON NMI ,,Florida:Product Approval #17022.5 !" Natlsttlp Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida.Product Approval Rule#61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 915" Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.2 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 - -- METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING 6"O.C. 6"O.C. SEAM ADHESIVE Not required 3/16"continuous bead (see details) I Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06& UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 EQUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897-12. *Des! n Pressure margin of safe Certificate of independence: Locke Bowden,P.E.does not have,not will acquire a financial ikqomstIry cgyecompany manufacturing or distributing products under this evaluation. �.`� `L D. 8r�;, Locke Bowden,P.E.is not owned,operated,or controlle�` 1�s'�41� mp� �tanrcturer,or distributing products under this report. f • '� seal a STATE OF r s it f ',Qfi r e J''�:::..{1611 I , Limitations: 1.Undedayment to be compliance with current Florida Building Code(FBC)2017 61h ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 61'ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method:l-D 4.Engineering analysis for"project specific approval by local authorities wfjudsdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w1FBC 2017 61h ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel-Details 16" –T— 3/4�" Panel Profile 16" o.c. 'a �.Z�. � V. i}�'y ' - '\- 'l .F- •l -:._\\v /� �.`,`1.`�i-i 't°.Y 'X J` -:Z)„�Y Deck: -15132"or greater Plywood,or -Wood plank Integral Snap Lock For METHOD 2: Apply 3116"Bead Bostik 915TM'Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel-Details Fastener #10 X V Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel —�—� / I Seam Adhesive Application: Deck: For Method 2 -15/32"or greater Plywood,or Apply 3116"Bead Bostik 915 TM Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A") Isometric View i 5/2812019 Florida Building Code Online BCIS Home i Log In I User Registration ; Hot Topics , Submit Surcharge Stats&Facts ; Publications Contact Us BCIS Site Map Links Search Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail �,(T ... ® o7y FL x JUL I r� 2019 FL5259 R28 Application Typeerrntt[ln9 p,paMerit Revision ®� Code Version P r I jcr"e COunt1 2017 ���5® ^ Application Status Approved RVe p ®�PB,jg4c f. Comments CODE (;je 00ut4 Y Archived ST■ LU 13®CC Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext 242 malpert@polygiass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email :1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAIpert@polyglass.com Quality Assurance Representative Arfel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach,FL 33442 (954)233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 COI 2018 01 COI NIEMINEN pd� Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 '2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012' 2012 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS`/o2fegOlipJYmiSimlPV6uypRuXszPogp/o3dp/o3d 1/2 / 5/1812019 ' Florida^ 8uU�ng�vdeOn�e m1897 2012 Equivalence of,pmuuct Standards Certified By Sections from the Code Product Approval Method Method 1Option o Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FacApproval 01/30/2018 bate Approved 04/10/2018 summary of Products FL# Model,Number Or Name Description Underlayments Limits of Use Installation Instructions -Approved for use outside HVHZ:Yes 1128.pifff Impact Resistant;N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created"rIndependent ''"'" '=`, '""other deck types and associated maximum ' Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R28 AE 2018.01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- under'layment system(over concrete deck)for R2810—f use under foam-on We systems(where the Created by Independent Third Party:'YEis underlayment forms part of the load-path). Refer to ER Section 5.6.4 for othersystems, / design pressures,2.)Refer to ER Section 5 for other limits of use. Contact uus:2601 Blair Store Road,Tallahassee FIL 32399 Phone: u�487-182 The State aFlorida is""^wsEOemployer, ,urivasuatamrnunt`Accesiffillity statement''uefunuaatemyn Under Florida law,email addresses are pu-blic records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact BSD.487,1395.*Pursuant to Section 455.275(l), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have'one.The smalls provided may be used for official communication with the licensee.Howeveir email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 4S5,F.S.,please click here. Product Approval Accepts: Credit Card Safe � � � | | . ' :/2