Loading...
HomeMy WebLinkAboutProduct Approval D1x41zU19 "rrrbrida�uilding Code Online 4 SCIS Home Log In User Registration Hot Topic Submit Surcharge Stats&Facts Publications Contact Us SCIS Site Map ( Links Search �' t`Product Approval Or RECEIVED FJUSEA:Pub!!c User - JUL 10 2019 Product Approval Menu>Product or Acplicatlon Search>BpdHcauon._Llst>Application Detall w M FL# FL7473-R8 ST.Lucie County, Permitting Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer EAGLE ROOFING PRODUCTS FLORIDA LLC Address/Phone/Emali 1575 East CR 470 Sumterville,FL 33858 _( (800)400-3245 annettes@eaglerooflng.com Authorized Signature Annette Sindatt!' annettes@eaglerooflng.com � ����c ° Technical Representative Tyler Allwood ® Address/Phone/Email 1575 East Country Road 470 Sumterville,FL 33585u ;ao (941)302-7$26 tylera@qagieroofing.com Quality Assurance Representative Address/Phone/Email •�� � a Category Rooflng { Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nierninen Evaluation Report Florida License PE-59166 Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W.Knezevich,PE Wi Validation Checklist-Hardcopy Received Certificate of Independence FL 473 R8 COI 2017 01 CO Niemin Wff Referenced Standard and Year(of Standard) Standard Year ASTM C1492 2009 FRSA/TRI April 2012 2012 SSTD it 1997 Equivalence of Product Standards Certified By Sections from the Code https://www.fioridabuildlnq.orq/Dr/Dr aDD dti.asox?oaram=wC�F1/XOvAnntRRunutGtt11Pt11RT#io/7f7nT7oo!_7F.,t�Altc7s�a�eoioa "^ --fi�r,- f 6/24/2019 -Abrida 9'.ullding Code Online Product Approval Method Method 1 Option D Date Submitted 10/16/2017 Date Validated 10/18/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 7473.1 Eagle Roof Tiles Low(fiat),medium and high profile concrete roof tiles Limits of Use Installation Instructions Approved for use in HVHZ:No FL7473 R8 II.2017 i0 FINAL ER EAGLE NON- Approved for use outside HVHZ:Yes HVHZ FL7473-RS.pd Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-59156 Design Pressure: N/A Created by Independent Third Party:Yes Other:See Section 5 of Evaluation Report for Limits of Use. Evaluation Reports Tile roofs are analyzed for wind resistance through overturning FL7473 R8 AE 2017 10 FINAL ER EAGLE NON- moment. Refer to FRSA/TRI 07320 for overturning moment HVHZ FL7473-R8.pdf limitations of mechanically attached the systems and the the Created by Independent Third Party:Yes adhesive manufacturers'Product Approvals for adhesive set tile systems. Oack Rlext iJ Contact Us::2601 Blair Saone Road Tallahassee FL 32399 Phone:550-487-1624 The State of Florida Is an WEED employer.Qgggd9ht 2007-201iState of Florida.::&LyagrVStatement;:Aaessibll(ty Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click here. Product Approval Acceptsi ® eCfuyS: M Credit Card Safe 6 . https://vvww.foddabuildinci.orcl/Ar/or avo dti.ast)x?oaram=wOEVXOwtDrlt8Bwwtlavl1PtVRTl1%9f7,nT7aoG7fiihAlIP7f11Mo/,Ar1 s REC� Up u EXTERIOR RESEARCH&DESIGN,I.I.C. J U L 10 2019 Certificate ofAuthorization#9503 UTRINITYIERD 353 CHRISTIAN STREET,UNIT#13 ST. Lucie,County, Permitting OXFORD,CT 06478 (203)252-9245 EVALUATION REPORT Eagle Roofing Products Florida I.I.C. Evaluation Report E1322.09.06-R5 1575 East Country Road 470, FL7473-118 Sumterville,FL 33585 Date of issuance:02/24/2009 (800)400.3245 Revision 5:10/16/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in they State of Florida.The documentation submitted has been reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building.Code (NON-HVHZ)sections noted herein. DESCRIPTION: Eagle Roof Tiles _ LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE:This,Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement-to notify Robert Nieminen, P.E. if the product changes'or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation.Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Evaluated by Robert Nieminen, P.E." may be displayed in advertising literature. If any portion of the Evaluation Report Is displayed, then It.shall be done in its entirety, INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the Job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert l.M..Nieminen F.E. The facsimile seal appearing was authorized by Robert Nleminen, Florida Registration No.59266,Florida DCA ANE1983 �'j�,�s�:.'r,"ii 9T='.` P.E.on 20/16/2017.This does not serve as an electronically signed t �✓nriiiiitE��.S document,signed,sealed hardcopleshave been transmitted tothe Product Approval Administrator and to the named client CERTiFiCATiON OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity lERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,,P.E.does not have,nor will acquire,a financial Interest in any other entity involved In the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor_Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. i ., QOTaINITYIERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing TIles Compliance Statement: Eagle Roof Tiles, as produced by Eagle Roofing Products Florida LLC, have demonstrated compliance with the following sections of the a Edition(2017) Florida Building Code(NON-HVHZ)through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations j Conditions of Use set forth herein. 2. STANDARDS: Section Prooerty Standard Year t 1507.3.5,R905.3.5 Physical Properties ASTM C1492 2003(2009) 1507.3.7,R905.3.7_ Attachment Requirements FRSA/TRI April 2012(04-12) 2012 1504.2.1.1 Overturning Moment SSTD 11 1997 3. REFERENCES: gd& Examination Reference Date ATL(TST 3782) ASTM C1492' RT0310.01-17,02-17,03-17 03/15/2017 ATL(TST 3782) ASTM C1492-freeze/thaw RT0706.01»17,02-17,03-17 •09/25/2017 Tile Roof institute SSTD 11 Membership Letter 11/29/2005 ATI(QUA 1844) • Quality Assurance Inspection Report 06/07/2017 4. PRODUCT DESCRIPTION: 4.1 'ASMiC149Z,r� Ype�Ul(LaW�kPr,{atilse} . 7. Irr 71.1 1 i ' '✓! EDITION(2017)FSC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-R5 Exterior Research and Design,LLC. FL7473-R8 Certificate oJAuthorhation#9503 Eagle Roofing Products Florida LLC.;(800)A00.3245 Revision 5;10/16/2017 Page 2 of 5 1 i I I r . TRINITY I ERD 4.2 ��''S1'lVtuG1°44 � Tyfse�lii:( `d)>'arrt ro#tl )"� � ' �'` �it'ila�lsu "' ' �'�� _ �� ��,�� *•�>r- , ���'�:� .@@ e NAiC R�Bf .+y a •'4296" 4.3 �C42i4Y4� i(High?Profiiie)` '� x r+;7><. i,.=;�_�€#'.�_ �i�;_ e��, x C,AP'S iF$A o x•,a 4�ir �a �*...�.;+'i+t S t,� +- ^�ryyy4:...... 'Ai V .w S. WiTATIONS; 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification Is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck)or listing by an approved testing agency for fire rating of this product. 5.4 Underlayment shall be that which holds Florida Product Approval for use with the roofing systems. The underlayment Product Approval shall specify allowable method(s) of the installation (mechanical attachment, mortar-set and/or adhesive-set) for use with the specific underlayment. For mortar-set or adhesive-set the roofing applications, the underlayment Product.Approval shall specify attachment methods for the underlayment system to resist wind uplift design toads in accordance with Table 1A of FRSA/TRI April 2012(04-12). 5.5 "Calor-Bonded"or "Slurry-Coated" files are limited to use on projects in areas subjected to weathering Indices of 50 or less(negligible weathering),as outlined in Figure 1 of ASTM C1492.03(2009)1,reproduced below for reference. This limitation does not apply to the"Color-Through"product offering. '�. v+iyir4: 5.0 ' 50 • ,'• ` :.•. WEATHERING REGIONS .�« :5—NEGLIGIBLE WEATHERING MODERATE WEATHERING iF.rs SEVERE WEATHERING 5.6 All products in the roof assembly shall have quality assurance audit In accordance with FAC Rule 811320-3. i Exterior Research and Design,LLC. e"EDITION(2017)FBC NON-HVHZ EVALUATiON Evaluation Report 62922.09,06-115 certificate ojAathni:atian X19503 Eagie Roofing Products Florida LLC.;(800)4003245 FL7473-RB Revision 5110/16/2017 Page 3 of 5 4 I ' i I TRINITY ERD 6. INSTALLATION: 6.1 Eagle RoofTiles may be mechanically fastened,mortar-set or adhesive-set. installation shall comply with manufacturer's current published Instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Tile installation Manual. 6.2 Underlayment shall be installed In accordance with FRSA/TRI April 2012 (04.12) or the underlayment manufacturer's current Product Approval. For mortar-set or adhesive-set the roofing applications, the underlayment current Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads In accordance with Table 1A of FRSA/TRI April 2012(04-12). 6.3 Tile Attachment: 63,1 Mechanically Attached Tile; Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012(04-12)to resist the Uplift Moment determined in Table 2A or 20 of FRSA/TRI April 2012(04-12)or FBC 1609.5.3. 6,3.2 1Mlortar-set Tile: Wind load resistance shall be in accordance with Table 2A or 28 of FRSA/TRI April 2012 (04-12)or FBC 1609.5.3 in conjunction with the mortar manufacturer's Product Approval. 6.3.3 Adhesive-Set Tile: Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04.12)or FBC 1609.3.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current version of the referenced Fiorida'Product Approval for paddy-placement details and performance data. "� r +TILE,AD ESIVEO'RVADHESNE`�SEitiLE SYSTEMS; , 'rh 5 x ,p SaF x, H Manufacturer > Products Florida Product Amoval "Touch N'Seal Storm Bond" FL14506 DAP Foam,Inc. FL21374 'Touch N'Seal Storm Bond 2" Dow Chemical "TILE BONDym'-' FL22525 "Polyset®AH-160" FL6332 ICP Adhesives&Sealants,Inc, FL6276 "Polyset®RTA-1" 6.3.4 HIP and Ridge TO Tile shall be installed In accordance with FRSA/TRI April 2012(04.12). For hip and ridge the installations atop hip and ridge metal,refer to the hip and ridge metal manufacturer's current Product Approval(e.g., - FL5374) or test report In accordance with SSTD 11 for allowable loads to resist those determined In accordance with Table.1A of FRSA/TRI April 2012(04-12). Evaluation Report 91322.09,06.115 Exterior Research and Design,LLC, 6r"EDITION(2017)FBC NON-HVH2 EVALUATION FL7473-R8 CerujleoM ejaaerlo�t:octon srsso3 Eagle Roofing Products Florida LLC„(800)400.3245 Revision 5:10/16/2017 Page 4 of 5 TRI 7. LABELING: i`dlTY I ERD 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. EA',,6,L% E FLOO DA , EAGLE FL (LOCATED ON UNDERSIDE OF TILE) (LOCATED ON FRONTSIDE OF TILE) 7.2 Tile not tested for freeze-thaw shall state clearly that the lot has not been tested for freeze-thaw acceptance on all tot tags or certification. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Sumterville,FL 10. QUALITY ASSURANCE ENTITY: - Architectural Testing,Inc.--QUA1844,(717)764-7700 -END OF EVALUATION REPORT- ASTM C1492-03,Standard Specification for Concrete Roof Tile,0 ASTM international Exterior Research and Design,LLC. 6'"EDITION(2017)FOC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-115 Certificate of Authartzotton#9503 Eogic Roofing Rroducts Florida LLC.,,(800)400-3245 FL7473-RS Revision 5:10/16(2017 Page 5 of 5 i r t' IL lnlaw.m JUL 1 0 2019 5i:Lucie County, permitting MIAMI--DADE COUNTY Now PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Strcet,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(796)315.2590 F(786)31S-2599 NOTICE OF ACCEPTANCE (NOAH www.mlamidade.eov/economy Tarco Specialty Products,Inc. One Information Way,Suite 225 Little Rock,AR 72202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. PER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this.product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami-Dade County Product Control Approved"",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if.there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to.comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0420.02 and consists of pages 1 through 15. The submitted documentation was reviewed by Alex Tigera. NOA No.;16-1116-09 Mwrtaa N1Y Expiration Date: .01125/22 i Approval Date: 01/12/17 Page 1 of is ti I Y y I 4' ROOFING COMPONENT APPROVAL E Category: Roofing Sub-Category: Underlayment Material: Asphalt,SBS,Polyester SCOPE: This acceptance is for Tarco Roofing Membrane and;Underlayments,for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved, adhesives,fasteners and fastener densities,as described in this Notice of Acceptance;designed to comply with the Florida Building Code,including the High Velocity Hurricane Zane of the Florida Building Code. .TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT** Product Dimensions Test Soecifieation Product Description 30#ASTM 3' x 72"rolls ASTM D226 Type II Asphalt saturated felt underlayment Specification Felt Manufacturing Location#1&#2 EasyLay 3'x 133' 4"rolls ASTM D226 Type 11 Sheet material comprising a polyester Manufacturingsubstrate coated with bituminous coating for Location#2 use as an underlayment in roofing applications. Designed as a,shingle and metal roofing underlayment-and for use in the roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. Fiberglass Mineral 3'x 36'rolis ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop or cold Roofing process application. Manufacturing Location#1 ASTM Organic Tile 3'x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Underlayment Type 11 underlayment for hot mop application. Manufacturing Location#3 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced,SBS modified bituminous membrane for hot mop or Manufacturing cold process application.Designed as a tile Location#1 roofing underlayment. i NOA No.:16-1116-09 MIAMI+DADECOUNTY Expiration Date; 01/25/22 Approval Date: 01/12/17, Page 2 of 15 t i Fast9O 3'x 36'rolls TAS 103 Granular surfaced,asphalt-impregnated Manufacturing ASTM D249 organic felt reinforced,bituminous sheet Location#1 ASTM D6380 material with a self-adhesive bottom layer,for use as an underlayment in sloped roof . assemblies. Designed as a the roofing underlayment. PS20er '3'x 66'8"rolls TAS 103 Fabric surfaced,fiberglass reinforced,SBS Manufacturing ASTM D1970 modified bituminous sheet material with a Location#1&#2 self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a shingle,tile and metal roofing underlayment. PS20eu 3'x 66'8"rolls ASTM D1970 Film surfaced,fiberglass reinforced,SBS Manufacturing modified bituminous sheet material with a Location 01&#2 self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3'x 66W'rolls ASTM D1970 Fine granular surfaced,fiberglass reinforced, Manufacturing 3'x 33'4"rolls bituminous sheet material with a self-adhesive Location 01&#2 bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle roofing underlayment. SS400 3'x 66'8"rolls ASTM D1970 Smooth surfaced,fiberglass reinforced, Manufacturing 3'x 33'4"rolls bituminous sheet material with it self-adhesive Location#1&#2 bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle and metal roofing underlayment. NR500" 3'x 668"rolls ASTM D1970 Filmsurfaced,non-reinforced,bituminous sheet material with a self-adhesive bottom Manufacturing layer,for use as an underlayment in sloped Location#3 roof assemblies, Designed as an ice and water shield,and a shingle and metal roofing underlayment. NOA No.:16-1116.09 MIAMtDADECOUNTY Expiration Date: 01/25/22 ► Approval Date: 01/12/17 Page 3 of 15 -f MANUFACTURING LQCATIOm 1. Greencastle,PA 2. Belton,TX 3. Coshocton,OH EVIDENCE SUBMITTED: Test A Mcy Test Identifier Test Name/Revort Date Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting,LLC PRI Asphalt Technologies TOT-003-02.01 ASTM D226 Type 11 08/22/02 TOT-029.-02.01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07 Trinity ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103;ASTM D6380 10/12/06 730160.08.09-R1 ASTM D1970 10/12/10 710550.07.08 ASTM D4798&ASTM D 1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 733190.08.10 TAS 103 08/06/10 743930.09.13-R2 TAS 104 09/11/13 T40790.04.12 ASTM D6380 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 ASTM D1970 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D1970 02122/08 NOA No,;16-1116,09 fNfAfNf•DADE GofJNfi Expiration Date: 01/25/22 MAN Approval Date: 01112117 Page 4 of 15 i APPROVED ASSEMBLIES=30#ASTM SPECIFICATION FELT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(1): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS--30#ASTM SPECIFICATION FELT: 1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NBCA)when installing 30#Felt. 3. During installation of 300 Felt,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents, 4. 30#ASTM Specification Felt shall be installed with a nunimum 4"end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS—30#ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type H felt as a component part ofan assembly in the Notice ofAcceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61020-3 of the Florida.Administrative Code. 1 NOA No.;16-1116-09 MIAMbDAD CqD Expiration Date: 01125/22 ... , Approval Date: 01112/17 Page 5 of 15 i APPROVED ASSEMBLIES-EASYLAY: Deck Type I: Wood,Non-insulated Deck Description: 19/32'' or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck Anchor Sheet: One or more plies of EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck, Fastening: Approved nails and tin caps 6"o.e,within lap and two equally spaced staggered rows 12"O.G. in the field(for Anchor/Base sheet).. Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type lI felt INSTALLATION REQUIREMENTS-EASYLA'Y: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices andcguidelr'nes as outlined by the National Roofing Contractors Associations(NRCA)when installing EasyLay. 3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents, 4. EasyLay shall be acceptable for use with asphaltic shingles,wood shakes said shingles,quant'slate,tile and metal roofing assemblies. 5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyLay, 6. Place a full width piece of EasyLay,parallel to the eave(low)edge of the roof. 7. Unroll EasyLay,2 to 3 feet,with the lay lines facing up;and position the end of it to'the edge of the eave and rake. 8. install a few fasteners at the top,near the rake,and roll out the sheet to a manageable length. 9. Pull,straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the cave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps.or approved cap nails,driven by hand or pneumatically,spaced 6"o.c.at all laps in the center of the searn area,and two staggered rows fastened 12" o.c,in the field of the sheet, 11. When installing nails,apply so that the head of the nail is flush with the EasyLay surface,without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down, 14. Align the next roll over the preceding sheet so as to form a minimum 4"overlap. 15. Then install the just placed sheet,per instructions above. 16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will flow over the top of E#ssyLay. . 17. Apply subsequent sheets in the same manner,with 4"side laps and 6"end laps over the preceding sheets, 18. When the top course is reached,lap about 6"of EasyLay over the ridge. NOA No.:16-1116-09 MIAMI DA OU Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 6 of 15 • 19. 'Install EasyLay a minimum of 6"up any vertical surfaces. 20. Stagger the end laps a minimum of 18"from the preceding course. 21. After installing EasyLay,on the field of the roof,install drip edge at the eaves(if used). 22. When applying EasyLay'in the valley,start at the low point and work to the high point,rolling thvmembrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay,install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used,but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas mustibe covered with code prescribed metal or other approved valley lining material. 26. Apply a minimum 1/16"thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cuts or tears have occurred.Seams or joints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LIMITATIONS-EASYLAY: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 'EasyLay shall be applied to a clean and dry surface. 4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's`published literature for additional information. 5, EasyLay shall not be used on slopes less than 2:1;2,unless the slope is acceptable to the weather resistant covering. In general,on slopes less than 4:122,a double layer-of EasyLay is recommended. Double layer application is best achieved by using 19"side laps,making sure the side laps are`shingled in'to. shed water. 6. When installing EasyLay,the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61420.3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The.manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding maximum time limitations., NOA No.:16-1116.09 M�ar1tDADEC Expiration Date: 01/25/27 Approval Date: 01112117 Page 7 of 15 i APPROVED ASSEMBLIES-=FIBERGLASS MINERAL SURFACED ROLL ROOFING: Deck Type: See Installation Requirements and General Limitations below. Deck Description: - See Installation Requirements and General Limitations below. System E(3): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS—FIBERGLASS MINERAL SURFACED ROLL ROOFING: L Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt,adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing Fiberglass Mineral Surfaced Roll Roofing. 3. During installation of Fiberglass Mineral'Surfaced Roll Roofing,comply with Occupational Safety and Health Administration(OSHA )safety standards;use common sense measures and adequate safety precautions to prevent accidents. GENERAL LEmATION'S--FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this.product, 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the-Florida Building Code and Rule 61020-3 of the Florida Administrative Code. 1 NOA No.;16-1116-09 MIAM•DADE•MIY Expiration Date: 01/25/22 � Approval Date: 01/12/17 Page 8 of 15 APPROVED ASSEMBLIES_ASTM ORGANIC TYLE UNDERLAYMENT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below, - System E(4): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS—ASTM ORGANIC TYLE UNDERLAYMENT: 1. ASTM Organic Tile Underlayment may be used.with any approved roof covering Notice of Acceptance listing ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt,adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with'roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing ASTM Organic Tile Underlayment. . 3.; During installation of ASTM Organic Tile Underlayment,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents.- GENERAL ccidents.GENERAL LIMITATIONS-ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61020-3 of the Florida Administrative Code; NOA No.a 16-1116.09 M�AM Q11DE couNTY Expiration Date: 41125/22 Approval Date. 01/12/17 Page 9 of 15 iI APPROVED ASSEMBLIES—EASYMOP.SBS: Deck Type 1: Wood,Non-Insulated Deck Description: Minimum 19/32"plywood;wood plank System E(5): Anchortsheet mechanically.fastened to deck,membrane adhered with hot asphalt or approved adhesive. Anchor/Base Sheet; One or more plies of ASTM D226 Type U or ASTM D2626 with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c,within lap and two equally spaced staggered rows 12" o.c. in the field(for Anchor/Base sheet only), Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as specified in RAS 118, 119 or 120. (See#13 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS—EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2, Observe and comply with roofing practices and,guidelines as outlined by the National Roofing Contractors Associations(NBCA)when installing EasyMop,SBS. 3, During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents, 4. EasyMop SBS shall be an.acceptable underlayment for mechanically fastened roof file and adhered roof tile applications. S. Re-fasten'any loose decking panels,and check far protruding nail heads prior to the application of EasyMop SBS, 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean,dry and,free of any loose debris.or moisture prior to the application of the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars,flashing,valleys,liner,drip edge and concrete deck substrate with ASTM D 41 primer. 9. Applicator may cut EasyMop SHS into sections for workability and allow to relax prior to application. J 10. Place EasyMop SBS over metal drip edge in accordance with RAS 111. 11, Install the first-course of EasyMop SBS parallel to the eave edge. 12. It is recommended that end laps be staggered a minimum of 18"from the preceding course. 13, EasyMop SBS shall be back nailed along the head lap.The nails shall be, 11 gauge 1'/a"approved ring shank type applied with a minimum of a 15/8"approved tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 12"o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed, 14. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. NOA No.:16-1116-09 MlANl�DADECOUN Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 10 of 15 GENERAL LIMITATIONS—EASYMOP SIO& 1. Fire classification is not part of this acceptance;;,refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications.Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when=any form of moisture such as water,dew,rain,etc.is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth,clean and dry surface,with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system. ' 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8. All tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per manufacturer's requirements,not to exceed G-high,to the standard maximum roof pitch of 5 :12 for flat tiles and 6:12 for lugged tiles(See Tile Staging Method diagram below). At roof slopes greater than'the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile.Staging Method " t . . .. mm+ "s2F.a^m ^tea •-$y.,'. - ,{ ;y 7 d j;41W""T'P'^'""5""'�pW�'�' h wv" PIS - k'd°vr.i:�e r i{�t.� '"< '�".•. s �' .�r`'T�,.. 1 i i ' ZF a a`" •, . fir k � hal #,• 1 1'.9 d Front View-Staged Tiles(Slope" Side View-Stageil'Piles (Slope 1) P. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 11. Refer to prepared roofing system Product Control;Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings.Notice of Acceptance listing Tarco,EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards.are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance,and fire testing results. , 12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61620-3 of the Florida Administrative Code, NOA No.;1G-1116,49 MlAMFDAD&`COUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 116f 15 APRUVED ASSEMBLIES--TARCO SELF-ADHERED UNDERLAYMENTS Deck Type 1: Wood,Nan-Insulated Deck Description: Minimum 19/32"plywood,wood plank System E(6): Anchor sheet mechanicallyifastened to deck,membrane adhered. Anchor/Base Sheet: One or more plies of ASTM D226 Type Il,ASTM D2626,or EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12" o.c. in the field(for AnchorBase sheet only). Membrane: All Tarco self-adhered membranes applied to approved Anchor/Base Sheet. (See#15 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. Deck Type 3: Concrete,Non-Insulated Deck Description: Structural concrete or concrete plank min.2500 psi System F(1): Membrane self-adhered to concrete deck. Deck Preparation: The concrete deck shall be clean and dry and cured for a minimum of 28 days Anchor/Base Sheet: None. Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8"approved tin caps at a maximum spacing of 9"o.c.at the head laps and be covered by the preceding layer.No back nail fasteners or tin caps shall remain exposed). Membrane: Tarco PS200HT self-adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Surfacing: Approved Roof Assemblies as specified below. NOA No.:16-1116-09 Expiration Date: 01/25/22 M1AMtDADECOUFifY Approval Date: 01/12/17 Page 12 of 15 INSTALLATION REQUIREMENTS—TARCO SELF-ADHERED UNDERLAYMENTS: 1. Turco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NBCA)when installing Tareo self adhering underlayments. 3. _ During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS2008T shall be acceptable underlayments for mechanically fastened roof the and adhered roof file applications. MS300 and SS400.shall be acceptable underlayments for asphaltic shingles,wood shakes and shingles,and slate or simulated slate roof assemblies. PS200 1 and NRS00e'''shall'be acceptable underlayments for asphaltic shingles,wood shakes,shingles,and metal roof panel assemblies. " 5. Re-fasten any loose decking panels,and check for protruding nail 'heads prior to the application of the Turco self adhering,underlayments. 6. Turco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean,dry and(free of any loose debris or moisture prior to the application of the Turco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars,flashing,valleys,liner,drip edge and concrete deck substrate with ASTM D 41 primer, water based acrylic or water based polymer modified primer, 9. Contractor may cut the underlayinents into sections.for workability and allow to relax prior to application. 10. . Place the underlayments over metal drip edge in accordance with RAS 111. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment,working from the center of the material continuously to the ends of the sheet(half of the length of the sheet is the center);taking care to avoid wrinkles and ridges. 13.- Remove the underlayriments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time,it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18"from the preceding course. 1S. Underlayments are to be back nailed along the head lap.The nails shall be, 11 gauge 11/4!'approved ring shank type applied with a minimum of a 1%"approve&tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 9"o.c. The head-lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas"side laps,end laps,T- joints"to ensure adhesion with acceptable substrates. A minimum of a"28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply i/s"thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive/flashing cement throughout the contact area of the 6"granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed,the membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1/$1h"asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions,slope changes,valleys,curbs,and other roof top penetrations before any,other sections of the roof. 19. When applying underlayments in the valley,start at the low point and.work to the high point,rolling the membrane from the center outward in each direction. NOA No.: 16-1116.09 'MMAM.QADECOUNN Expiration Date: 01/25/22 ��� � Approval Date: 01/12/17 Page 13 of 15 s. X . h 20, For ridge applications,center the underlayment and roll from the center outward in both directions. 21. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code, 22. All protrusions or drains shall be initially tapedmith a 6"piece of like kind membrane, The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. GENERAL LIMITATIONS—TARCO SELF-ADHERED UNDERLAYMENTS: 2. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 400 F and rising, 4. Tarco self-adhered underlayments shall not be installed when any form of moisture such as water,dew,rain,etc. is present on the substrate, 5. Tarco self-adhered underlayments are to be applied to a sinooth,clean and dry surface,with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self-adhered underlayments. 7. Tarco self-adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self-adhered membranes,wait a minimum of 48 hours before roof loading'of tiles. 9. Care should be taken during the loading.procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment, 10. All tiles shall be staged(two tiles perpendicular to,slope,four tiles on top parallel to slope)as per manufacturer's requirements,not to exceed 6-hig4,to the standard maximum roof pitch of 6 :12 for flat tiles and 6:12 for lugged tiles(See Tile StagingMethod diagram below), At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile,Staving Method Y t �a 4} i Front View-Staged T11es(Slope ->) Side View Staged Tiles (Slope J) NOA No.:16-1116.09 MIAMI DUDE cour�n Expiration Date: 01/25/22 Approval Date: 01112117 Page 14 of 15 s ' 6 i 11. The manufacturer reserves the right to change the the staging method-at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 12. EasyLay,PS200mu MS300,SS400,and NR500''shall not be left exposed as a temporary roof for longer than 30 days after application. PS20e shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding maximum time limitations. `13. NR500nT is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products, Tarco self-adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. ` If Tarco self-adhered underlayments or the ASTM standards are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance,and fire testing results. 15. All products lised herein shall have a'quality assurance audit in accordance with the Florida Building Code and Rule 61020-3 of the Florida Administrative Code. MANUFACTURER'S CONSIDERATIONS: 1. When using Fast90 and PS200'in the roofing applications,use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended.When using EasyMop SBS in file roofing applications,use of loading battens or toe boards on roof,slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended, 2. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1> This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate .the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city, state and the following statement: ,Miami-Dade County Product Control Approved,or the Miami-Dade County Product Control Seal as shown below. MOO-. DEC••TY ,..>� � END OF THIS ACCEPTANCE a � NOA No.:16-1116-09 Expiration Date: 01/25/22 Mtartt• nE eaurtTr Approval Date: 01!12117 Page 15 of 15 i r - \a � r o ♦ i3 1 . e 9 e BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications Contact Us SCIS Site Map I Links Search Florida Pr USER:Pub"c:User al — -- R V C �a s Product Aooroval Menu>Product or Aonlication Search>Application List>Application Detail J U L 10 O 2019 FL# FL14317-R10 L Application Type Revision SST. Lucie County, Permitting Code Version 2017 Application Status Pending FBC Approval Comments Archived Product Manufacturer Boral Roofing/MonierLifetile Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine,CA 92618 (602)269-2288 Ext 8320 thomas.jemmett@boral.com Authorized Signature Thomas Jemmett thomas.jemmett@boral.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW 20th Street Boca Raton,FL 33431 (954) 520-5461 acoopeer@minierlifetile.com Quality Assurance Representative Address/Phone/Email - Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer G Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/21/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL14317 RSO COI 2018 01 COI NIEMINEN.Pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 FRSA/TRI(April 2012)04-12 2012 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/12/2018 Date Validated 10/15/2018 Date Pending FBC Approval 10/22/2018 Summary of Products FL# Model,Number or Name Description 14317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL14317 RSO II 2018 10 FINAL ER BORAL Underlayments FL14317- Approved for use outside HVHZ:Yes R10.pdf Impact Resistant: N/A Verified By: Robert J.M. Nieminen PE-59166 Design Pressure: +N/A/-210 Created by Independent Third Party:Yes Other: 1.)The design pressure in this application Evaluation Reports pertains to a particular underlayment system for use FL14317 R10 AE 2018 10 FINAL ER BORAL Underlayments FL14317- under foam-on tile systems. Refer to ER Section RSO pdf 5.6.4. 2.) Refer to ER Section 5 for Limits of Use. Created by Independent Third Party:Yes Sack Nettt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO,employer.Sgpyright 2007-2013 State of Florida.:; r va Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: - Credit Card Safe f I _ R5C51VEO JUL 10 2019 NEORECta. ST. Lucie County, Permitting Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Boral Roofing Evaluation Report M35710.12.10-1111 7575 Irvine Center Drive,Suite 100 FL14317-R10 Irvine,CA:92618 Date of Issuance:12/21/2010 (602)269-2288 Revision 11:10/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida.Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes.to the product(s),the Quality Assurance or the,production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words"NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: .,oma..•-+s'"'"`°..ep',�"" =,� + L tr 'Lys;•'p;f.TS 07.r��' Robert J.M.Nieminen P.E. •ti•^e+s.: The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ";!�i;„?' Nieminen,P.E.on 10/12/2018.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued., 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. . N.. NEMOletc. ROOFING COMPONENT EVALUATION: O. Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. .••. Section Property. Standards Year (( I 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 J Entit Examination s Reference' _ Dater —gC..___ _-._____._ ._ v �_... ERD(TST 6O49)µ Physical Properties M36790.07.11 09/30/2011 ERD(TST 6049) Physical Properties 840380.08.12 08/28/2012 ERD(TST 6049) Tensile Adhesion/LTA C41420.09.12-2 09/11/2012 ERD(TST 6049) Adhesion B41940.09.12 09/13/2012 ERD(TST 6049) Tensile Adhesion/LTA B47390.07.14-1 07/31/2014 ERD(TST 6049) Tensile Adhesion/LTA B47390.09.14 09/04/2014 OC(PDM1838) Physical Properties Equivalency statement 11/02/2017 PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI(TST 5878) Tensile Adhesion/LTA NEI-046-02-01REV 12/17/2010 PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI(TST 5878) Tensile Adhesion/LTA DAPF-002-02-01 03/08/2018 PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018 UL,LLC.(QUA 9625) Quality Assurance Service Confirmation Exp.08/21/2020 4. PRODUCT DESCRIPTION 4.1 Boral® TileSeal 501T is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970. 4.2 Boral® TileSeal"T is a nominal. 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI 04-12. 4.3 Boral® MetalSeal"T is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI 04-12. 4.4 GatorSeal®is a nominal 55-mil thick,granular-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen roof underlayment;meets ASTM D1970. 4.5 Citadel®Plus is a nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in multi-ply underlayment systems;meets ASTM D1970. MEMO ETC,LLC Evaluation Report M35710.12.10-Ril Certificate ojAuthorization#32455 VH EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2618 Page 2 of 8 07 .14EM01 etc. ,5. LwITATIONS: 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any'project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable..Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions for multi-ply underlayment options. TABLE 1- ROOF COVEROPTIONS .Asphalt Adhesive set Wood Shakes Underlayment Nail-On Tile Metal :Slate Shingles �`° .:;"Tie g's� , ��' &-Shingles A: .. Boral TileSeal 50HT Yes No No Yes Yes Yes Boral TileSealHT Yes Yes Yes Yes Yes Yes (See 5.5.1) Boral MetalSealHT Yes Yes Yes Yes Yes Yes (See 5.5.1) GatorSeal Yes No No No- Yes Yes 5.5.1 "Adhesive-set Tile"is,limited to use of following Approved tile adhesives/underlayment combinations. TABLE IA-ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONS' Florida Product 4 Adhesive Underlaymentr . Approval DAP Foam Touch'n Seal Storm Bond Roof Tile Adhesive FL14506 Boral TIIeSeaIHT or Boral MetalSealHT DAP Foam Touch'n Seal StormBond 2 Two-Component HT Hr Polyurethane Roof Tile Adhesive FL21374 Boral TileSeal or Boral MetalSealHT Dow TILE BOND""Roof Tile Adhesive FL22525 Boral TileSealHT or Boral MetalSealHT ICP Adhesives Polyset®AH-160 FL6332 Boral TileSealHT or Boral MetalSealHT ICP Adhesives Polyset®RTA-1 FL6276. Boral TileSealHT or Boral MetalSealHT 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approvalfor Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report M35730.12.10-1131 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ'EVALUATION FL14317-R10 " Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018 Page 3 of 8 ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Citadel Plus, Boral TileSeal 50"T, Boral TileSeaJIT,Boral MetalSeal"T or GatorSeal: ➢ Plywood(unprimed or primed with ASTM D41 primer). Boral TileSeal"T or Boral MetalSeal"T: ➢-OSB(unprimed or primed with ASTM D41 primer). Note:Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the overlying roof cover is adhesive-set tile roofing 5.6.2 Bond to Base Laver Underlavment: Citadel Plus, Boral TileSeal 50"T,Boral TileSeal"T,Boral MetalSeal"T or GatorSeal: ➢ ASTM D226,Type II felt;Citadel Plus. For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum codified requirements. For installations under adhesive-set tile systems,base layer shall be attached per minimum requirements of FRSA/TRI April 2012(64-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T,Boral MetalSeal"T or GatorSeal: ➢ ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc.). Boral TileSeal"T: ➢ Huber Zip Deck(unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underlavment Systems in Adhesive-set Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment systems beneath adhesive-set tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in adhesive-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure=-120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 to the plywood deck Base Ply: Citadel Plus,self-adhered Cap Sheet: Boral TileSealHT or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1'/0"ring shank nails through 32 ga., 1-5/8"diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-142.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga., 1-5/8"diameter tin caps spaced 12-inch o.c. NEMO ETC,LLC Evaluation Report M35710.12.30-Rll Certificate oJAuthorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018 Page 4 of 8 i ONEMOletc. #3 Maximum Design Pressure=-202.5 psf: Deck: Min: 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-210.0 psf: Deck: Min: 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK#89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal"T or Bora l;Meta lSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12.ga.x 1'/0"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional)Citadel Plus,self-adhered Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T;self-adhered 5.6.4.1 Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design pressure requirements may•not exceed-120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation,prior to placement of final roof cover. Boral TileSeal 50"T, Boral TileSeal"T or Boral MetalSeal"T shall not be left exposed for longer than 180-days after installation,prior to placement of final roof cover. Citadel Plus,for'use as a base-layer in a,multi-ply underlayment system,shall not be left exposed for longer than 180-days after installation,prior to placement of subsequent underlayment layer. 5,8 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)1: When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DI• .MaximuiYSlope Boral TileSeall or Flat Max.10-tile stack 6:12 Boral MetalSeal"T Lugged Max.10-tile stack 6:12 6. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. . NEMO ETC,LLC Evaluation Report M35710.12.10-R31 Certificate of Authorization'#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018 Page 5 of 8 ONEMOletc . 6.4 Citadel Plus: 6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal. 6.4.2 Slope limitations are those associated with the top-layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge, extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area,minimum 2 inches(horizontal lap)and minimum 6"end(vertical)laps., Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral.TileSeal 501, Boral TileSeaJIT, Boral MetalSeall or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226,Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi-ply system. Install optional Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 501, Boral TileSeal"T or GatorSeal. Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design pressure requirements may not exceed-120 psf. . M1 6.5 Boral TileSeal 50"T: L 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 501T on roof pitches less than 2:12. 6.5.3 Non-Tile Applications, Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge, extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c.for slopes below 7:12 and maximum 12-inch o.c.for slopes 7:12 and greater. Overlap successive courses the entire width of the black-selvedge area,minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC,LLC Evaluation Report M35710.12.10-R31 Certificate oJAuthorization#32455 P EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-1110 Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018 Page 6 of 8 ONEMOjetc. 6.5.4 Non-Tile Applications,to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 501r in accordance over ASTM D226,Type II felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3,except end(vertical)laps,described below. Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface,rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non-Tile applications, Direct to Deck: Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge, extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black-selvedge area,minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular or mineral top surface,rolling the interface into place with a weighted roller,or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non-Tile Applications,to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226,Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical)laps,described below. Apply SBS Mastic under all side(vertical)laps or any other laps where the self-adhering bituminous underside is in contact with the granular top surface,rolling the interface into place with a weighted roller. 6.7 Boral TileSeal"r or Boral MetelSeal"r: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSealHT or Boral MetalSealHT on roof pitches less than 2:12. 6.7.3 Non-Tile Applications, Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the-deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails &tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC,LLC Evaluation Report M35710.12.10-1111 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018 Page 7 of 8 I O.- NEMOletc. 6.7.4 Non-Tile Applications,to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSealHT or Boral MetalSealh7 over ASTM D226,Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3,except end(vertical)laps,described below. Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface,rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1.herein,using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design pressure requirements may not exceed-120 psf. Refer to Section 5.8 for the staging limitations. Battens must be used for all tile installations atop Boral TileSeal"T or Boral MetalSeal"T with roof pitches of 2'/:to less than 3:12. Boral Roofing's Elevated Batten'System or counter battens are required. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Brentwood, NH QUALITY9. UL,LLC.—QUA9625;(631)546-2458; Kanchi.Asrawala-Dokania@ul.com -END OF EVALUATION REPORT- NEW ETC,LLC Evaluation Report M35710.12.30-1111 Certificate ojAuthorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments;,(602)269-2288 Revision 11:10/12/2018 Page 8 of 8 • L