Loading...
HomeMy WebLinkAboutTamko Heritage FL#18355.1Florida Building Code Online Page 1 of 2 U ii (It, BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search bd Product Approval I I USER: Public User Product Annroval Menu > Product or Anolication Search > Annlicotion List > Application Detail FL # FL18355-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method TAMKO Building Products, Inc. PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Kerri Eden kerri_eden@tamko.com Kerri Eden PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Roofing Asphalt Shingles vL laj�5 � Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By Locke Bowden P.E. ,/ Validation Checklist - Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final.pdf Referenced Standard and Year (of Standard) Standard ASTM D 3161 ASTM D 3462 ASTMD D 7158 TAS 100 Equivalence of Product Standards Certified By Sections from the Code Year 2016 2010 2011 1995 Approved Testing Lab FL18355 R4 Eguiv UL letter for standards for FBC 2017.1)df http://www.floridabuilding.orsz/pr/pr app dtl.aspx?param=wGEVXOwtDauvosrHazGXO... 1/7/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/25/2017 09/27/2017 10/08/2017 12/12/2017 FL # Model, Number or Name Description 8355.1 Glass -Seal, Elite Glass -Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles eritage, Heritage Premium, eritage Woodgate, Heritage Vintage, Hip and Ridge, and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL18355 R4 II TBP15001.4 2017 FBC Eval Report Shingles final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL18355 R4 AE TBP15001.4 2017 FBC Eval Report Shingles final.pclf Created by Independent Third Party: Yes ❑ack Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Capp; riaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: pChecl M Credit Card Safe httn://www.floridabuildina.ori!/nr/nr ann dtl-asnx?naram=wCTRVXOwtDniivnsrHa7.CTXO 1 /7/?019 Certificate of Authorization No. 29824 CREEK17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480 3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September25, 2017 220 West 4"' Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick, MD Dallas, TX Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5. 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 2010A UL LLC (TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC (TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 08CA59132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 1OCA50498 ASTM D 3462 2010A UL LLC (TST9628) 1OCA64882 ASTM D 3161 2016 UL LLC (TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 12CA24551 ASTM D 3161 2016 UL LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC (TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. G R K TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass -Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. �eg'e 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass erick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Vintage® 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. K TAMKO BUILDING PRODUCTS j-�D Asphalt Shingles TECHNICAL SERVICES, LLC i ae Basic Wind Speed (V it): Max. 194 mph a , Frederick, Joplin, Basic Wind Speed (Vasd): Max. 150 mph Phillipsburg & Tuscaloosa) Deck (HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage® Premium (Dallas, Frederick new construction; Min. 15/32 in. plywood existing construction. Phillipsburg & Tuscaloosa) Deck (Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage® Woodgate new construction; Min. 7/16 in. OSB existing construction. (Dallas & Frederick) Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 6-1/8" FASTENERS NAIL ZONE j:::,:. COMMON 80ND EXPOSURE 5-5/8" 11�- 12-112" -- -- 12-3/81' 1 2-1/2 `-►I h--1 " Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) NAIL ZONE COMMON BOND IE 5-5/8" 1 "—� �r-112'�-- 7-1/2"-�- 7-3/8'� 7-1 /2"�►�+7-1/2"� h1-1 " Figure 4. Heritage® & Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC NAIL ZONE/ COMMON BOND T 6-1/S" �EXPOSURE5 518" 1" �7-112+7-1/2'44 7-3/8+-1/2+7-1129� Figure 5. Heritage® Woodgate 6 Nail Pattern ED Common Bond i co 7 39-3/8" Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate Alternate 6 Nail Pattern PAINT LINE, 7-7/8" T i- - - -------------------------------------------------------------------------------------I >~NAI L ZONE 6-1/8" EDGE OF COMMON BOND EXPOSURE 5-5/8" ACCEPTABLE -,"FASTENER LOCATION DO NOT FASTEN ALONG EDGE OF ------------------- ---------- COMMON BOND PREFERRED FASTENER LOCATION Figure 7. Heritage® (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Hip & Ridge Basic Wind Speed (V ic): (Frederick & Joplin) Basic Wind Speed (Vasd) Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Directions of prevailing wind Start 5-1/8" exposure here---, rn1 Figure 1 a„ 1 if Fastener "5-5/8" Figure 2 o- iia-- exposure Figure 14. Hip & Ridge (Frederick & Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. C RE K TAMKO BUILDING PRODUCTS 14 Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. ,,11It1111111,1'' R '- 2017.09.25 No 74021 1 1:31:41 ilr ; •14/' _04'00' STATE OF :0�` '•A, Q • Zachary R. Priest, P.E. i 40 R �. ' �? ��` ''""110NA� Florida Registration No. 74021 � ``� Organization No. ANE11669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.