Loading...
HomeMy WebLinkAboutBuilding Permit Application All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Dater 1 `s �`� Permit Number: r`101'd3d3 RECEIVED • , JUL 1 2019 Building Permit Applicat'Iu�ieCounty, Permitting Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential .� PERM IT TYPE: 1 0610 161;8,;Y1q C�]�55 � ✓?�-- �v�n G� PROPOSED LMPROVEMENT LOCA ION:. ; Address: n u �ca, I L OLH­?-�o Property Tax ID#: ;>� j `d U C�lz� '('GYM ' �j Lot No. Site Plan Name: Block No. Project Name: DETAILED DESCRIPTION OF WORK. n " CONSTRUCTION INFORMATION: Additional work to be performed under this permit-check all that apply: _Mechanical _Gas Tank _Gas Piping _Shutters _Windows/Doors Electric _Plumbing _Sprinklers _Generator _Roof Pitch Total Sq. Ft of Construction: Sq. Ft.of First Floor: Cost of Construction:$ (�,�75 Utilities: —Sewer _Septic Building Height: OWNER/LESSEE:' CONTRACTOR: Name q nezJ Name:, �� Address: 151074 ZYc u-e►-n ess Gja-u Company: , 131L 0 x-Ie7i o J-S-L,C City: L State: Address: 12U/ �lv l�s'1 f rnG Ye 5� Zip Code: ?)go-Wo Fax: City: State: Phone No. 3Z 4--y 1 X 0 Zip Code: -3 LJ 9V 3 Fax: E-Mail: Phone No `7-2 'J73 -6e-aC-6 _ ,t Fill in fee simple Title Holder on next page(if different E-Mail 1 ITU & 1 h f%0-X--f e-l"'//nr5 • CD.6ni from the Owner listed above) State or County License /.� t�9-7 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. If value of HVAC is$7,500 or more,a RECORDED Notice of Commencement is required. �fn SUPPLEMENTAL CONSTRUCTION LIEN,°LAW INFORMATION: DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Signatu of Owner ssee/Contractor as Agent for Owner Sign ture of C tractor/Lice a Holder STATE OF FLORIDAC-,r STATE OF FLORIDA'I,/ , CPP COUNTY OF -:t— I�fI�C(� COUNTY OF The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this M day of Y 20by this 1t_day of 20J by �P✓Am K IGk 1cm "'Tp►rnlad K96l�►►71'�I Name of person making statement. Name of person making statement. Personally Known X OR Produced Identification Personally Known�_OR Produced Identification Type of Identificatio Type of Identificati Produced, N Notary Public state of Florida 0 d „r a�p„hi r State of Florida r Joshua ane Alberico ? f: Joshua Shane Alberico Q My Commission GG 020879 y� My commission GG 020879 �OF Expires 08118/2020 @ofIV d' Expires 08/16/2020 (51gg- re of Notary Public-State of Florida) igrrandre of Wary Public-State of Florida) Commission No. (Seal) Commission No. (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. �, - "i' _ . 10124 INVERNESS WAY RECEIVED JUL 1 5 ?0,19 4 72 X96 ST. Lucia caurity, permitting SGD 1 2 3 104 X 96 36 X 56 FIXED 144 X 96 SGS SGD K ��C OENING SIZE 1 104 X 96 SGD 2 36 X 56 FIXED GLASS 3 144X96 SGD 4 17FX 96 SGD ---.� Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit# Owners Name t c ,va ,,h e LI) Applicant: , Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Design Pressure Number Type Windows Mullions c _ Fixed Glass Block Glass n c re+ M Skylights C Sliding Glass Doors nix I U LZ Swing Type Doors French Doors 0 Garage Doors Hurricane Protection Roof Ventilation Roofing Material Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Signature: seal. Design Prof: Cert.No. Date: BCIS Hpme Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff �• BCIS Site Map i Links Search Florida "-4 Product Approval pr N USER:Public User RECEIVE® Product Approval Menu>Product or Application Search>Application List>Application Detail JUL 15 2919 + FL# FL22401 Application Type New �T, L L Clo.•G+ unC y, Permitting Code Version 2017 -- -- ---- - Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer "MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.co C Technical.Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/C5A 101/I.5.2/A440 2011 ASTM E1886 2005 ASTM E1996 2012 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/08/2017 i J Date Validated 06/21/2017 Date Pending FBC Approval Date Approved 06/29/2017 Summary of Products FL# Model,Number or Name Description 22401.1 Series 120/130/140 Aluminum Series 120/130/140 Aluminum Sliding Glass Door-Non- Sliding Glass Door Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22401 RO C CAC 16368.pd Approved for use outside HVHZ:Yes FL22401 RO C CAC 16371.pd Impact Resistant.No Quality Assurance Contract Expiration Date Design Pressure:N/A 02/02/2022 Other.Refer to Installation Drawing Installation Instructions FL22401 RD IT 08-03087.nd Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party:Yes Evaluation Reports FL22401 RO .6E 513976.pd Created by Independent Third Party:Yes 22401.2 Series 120/130/140 Aluminum Series 120/130/140 Aluminum Sliding Glass Door(OXO)- Sliding Glass Door Non-Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22401 RO C CAC 163-6,6.pd Approved for use outside HVHZ:Yes FL22401—RQ_C CAC 1072.p f Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:N/A 02/0812022 Other:Refer to Installation Drawing Installation Instructions FL22401 RO II 08-03089.odf Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party:Yes Evaluation Reports FL22401 RO &E_S_13978 pff Created by Independent Third Party:Yes 22401.3 Series 120/130/140 Aluminum Series 120/130/140 Aluminum Sliding Glass Door-Impact Limits of Use Sliding Glass Door Certification Agency Certificate Approved for use In HVHZ:No FL22401 RD C CAC jfij§_9pdf Approved for use outside HVHZ:Yes FL22401 RO C CACjfij7_0_.pAf Impact Resistant:Yes Quality Assurance Contract Exp"tion Date Design Pressure:N/A 11/2912021 Other.Refer to Installation Drawing Installation Instructions FL2240 _U IL0_8-03086 pdf Verified By:LUIS ROBERTO LOMAS 62514 Created by Independent Third Party;Yes Evaluation Reports FL22401—RD &E 513975.pd Created by Independent Third Party:Yes 22401.4 '130/140 Aluminum Series 1201130/140 Aluminum Sliding Glass Door(OXO)- Glass Door Impact Limits of Use Certification Agency Certificate Approved for use In HVHZ*No FL22401 RO C CAC 16367,pd Approved for use outside HVHZ:Yes FL22401 RO C CAC 16373.pd Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure*N/A 12/19/2021 Other:Refer to Installation Drawing Installation Instructions FL2240RO 11 08-03088.Dd Verified By:LUIS ROBERTO LOMAS 62514 Created by Independent Third Party:Yes Evaluation Reports FL2240 RO AE 513977.pd Created by Independent Third.Party:Yes Back Nert Contact Us 2601 Blair stone Road.Tallahassee FL 3239.9 Phone:850-487-1824 The State of Florida Is an AAJEM employer.Copyright 2007-2013 State of Florida.::Privacy Statement::A2mmElbifiN Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public­records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for of communication with the licensee.However email addresses are public record.If you do not wish to supply a personal REVISIONS R& DESCRPWN DATE AM= NOTES: FOR ANCHORING HR LICH FRAME INMASONRY/CONCRETE E 4 A NS WITH US 1 P%TE WITH I 0ENT INTO SUBS T 0 To 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH T 'iAPCONS WITH FOR THROUGH FRAME INTO USE 1/4' SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE WITH I ST OCA AN AS N IN ELEVATIONS AND REQUIREMENTS OF THE FLORIDA BUILDING CODE, M 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 7/8" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE ALLATIODE Al RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 16,FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #14 SMS OR SELF 3. 1X SUCK OVER MASONRY/CONCRETE IS OPTIONAL. DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND 4. WHERE SHIM OR SUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED DETAILS, 17, ALL FASTENERS TO BE CORROSION RESISTANT, INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO 18, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL, MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE, WINDOW UNITS MAY A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0,42 BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI, MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm-2,OOCPSI MINIMUM. 6. WHERE 1X SUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED D. METAL STRUCTURE: STEEL 18GA (048") FY=33KSI/FU=52K5I OR COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF ALUMINUM 6063-TS FU=30KSI .048" THICK MINIMUM THE ARCHITECT OR ENGINEER OF RECORD. 19. APPROVED CONFIGURATIONS: OX, XO, XX, OXXO, PX, XP, PXXP, PIX, XIP, PlXxIp, XIX, OIx, 7, BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS X10, PDX, XUP, XIIX' COX, X110, PRIX, XHIP PROVIDED. 20,DOOR ASSEMBLIES INSTALLED IN AREAS WHERE OVERHANG RATIO IS EQUAL OR GREATER 8. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE. BEARING SHIM. SHIM WHERE SPACE OF 1/16- OR GREATER OCCURS. MAXIMUM ALLOWABLE OVERHANG RATIO = OVERHANG LENGTH/OVERHANG HEIGHT. SHIM-STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11, FRAME MATERIAL' EXTRUDED ALUMINUM 6005-T5. 12.UNITS MUST BE .g-LAZEa-PER-*STM-ET3UU--VV09;-SEE-SHEE-r-•24-FOR GLASS DETAILS. r 13, APPR�aE ACT PROTECTI EQUIRM FOR THIS PR6bkr-IN--WINP, FINE DEB S. ROBING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE 1 IA SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, SIGNED:0611412017 MI WINDOWS AND DOORS LLC 650 WEST GRATZ.MPA17ARKET 030STREET 5 TABLE OF CONTENTS SERIES 120/130/140 ALUMINUM SLIDING SHEET NO. DESCRIPTION GLASS DOOR - IMPACT NOTES v-;4pw'.'xz: TAT 0 -;o i NOTES �!,C, DRAWN: DN NO. REV 0 R 2 - 3 ELEVATION, ANCHORING LAYOUTS AND CHARTS R.S. 10V N 08-03086 ONAL NN 04/13/17 ISH-1 w//1111t 4 PLAN VIEWS NTS DATE OF 24 %%VN 5 - 23 INSTALLATION DETAILS LROMTOLOU015P.E. Luis R. Lomas P.E. 24 14M WOODFORD RD LEMMUE,NCS C 2= :FL No. 62514 GLAZING AND SILL RISER DETAILS 044W609 illomas@lrtomaspe.com REVISIONS HEY DESCRFWN DATE APPROVED � 191 MAX FRAME WIDTH 6„ MAX t-- ti t MAX ?.C. 6" MAX I 6" MAX (2} ANCHORS Chart#1:Units with 2 nota PER LOCATION Number of anchor tocatione required(2 anchors Par location SEE CHARTS Frame Frame Width n 1, 2 & �#3 Height 48.00 60.00 7200 84.00 96.00 FOR 2 & n N A S Jamb N--&S Jamb HAS Jamb HAS Jamb HAS Jamb 80.00 4 a 4 6 6 1 6 8 8 7 6 OF LOCATIONS 64.60 4 1 6 4 6 5 8 6 6 7 6 90.00 4 1 8 4 0 6 6 8 8 7 6 16" 96.00 4 7 4 7 5 7 6 7 7 7 MAX MAX O.C. FRAME T--- *V HEIGHT Chart 62;Units with 3 panels Number of anchor locations required 2 anchors per location Frame Frame Width In onHeight) HAS Jamb HASR00 1 Jamb HAS&Jamb HAS00 F &OT Jamb HAS Jamb 80.00 5 06 6 ? 6 9 6 10 6 �,r 84.00 5 8 6 6 7 6 9 6 10 B // 90.00 5 6 8 8 7 8 9 8 10 6 ii � ./� j/ 86.00 5 1 7 6 7 1 7 7 9 1 7 10 7 .L� 6" MAX Chart#3:Uttitswith4 attets SERIES 120 ALUMINUM SLIDING GLASS DOOR-IMPACT2,3 &4 TRACK(OXXX) Numbor cf anchor tocationa re utrod 2 anchor°per location -_- Frame Frame Width In EXTERIOR VIEW Height 06.00 120.00 144.00 166.00 19200 FINLESS&FLANGE INSTALLATION r� n H&S Jamb H&S Jamb H&S Jamb HAS Jamb H A S Jamb 80.00 7 1 8 8 8 1 10 1 6 11 6 13a 84.00 7 a 8 6 10 1 6 11 6 13 6 90.00 7 6 8 6 10 8 11 6 13 6 WITH STANDARD SILL WIT1425/8"&3112'SILLEXTENDERS 9600 T T 8 7 10 1 7 11 7 13 7 DESIGNPRESSURERATING IMPACTRATING DESIGNPRESSURERAT/NG IMPAC7R477NG +15.01-55.OPSF LARGEAND5MALL t55.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE IMPACT MISSILE LEVEL D,WIND ZONE MISSILE LEVEL D,WIND ZONE 3 WHERE WATER PENETRATION RESISTANCE IS REQUIRED WHERE EATER PENETRATION RESISTANCE IS REQUIRED SIGNED:06/14/2017 WITH STANDARD SILL,2518"&3112°SILLEX7ENDERS MI WINDOWS AND DOORS LLC 1R�It/a��z J 650 WEST MARKET STREET �\ \ ...•. DESIGNPRESSURE RATING IMPACTRATING GRATZ, PA 17030 ` NOTES: LARGEANDSMAtL SERIES 120/130/140 ALUMINUM SLIDING �*• 0 61�4.'' •� *= 1. MAXIMUM PAREL SIZE 48 518"x9312° t55 OPSF MISSILE IMPACT GLASS DOOR - IMPACT 2. M4XIMUMD.L0.:40581x e5i12• ELEVATION MENET LEVEL0,WSTANCEIND E3 DROWN; Dwa NO. qty �w•;��0RVDV. WHERE WATER PENETRATION RESISTANCE IS NOT REQUIRED - • R.S. 08-03086 - S1OMA11. \�� sCUE NTS WAIF 04j13j17 j/ 2 OF 24 �1 i HARDWARE SCHEDULE �i A ITANDEM ROLLER, SEMBLY 2 PER PANEL 8'FROM EACH END OF BOTTOM RAIL L ROBERTO LOMAS P.E. Luis R. Lomos P.E. B. LOCK HANDLE,IPER OPERABLE PANEL ATLOCK STILE.39"FROM TIIEBOTTOMRAL 14324-M-069 19omRD Wt9VRLE,ecom FL No.: 62514 434.668.0609 r0omasCa7Mamasye.com 4 7/16" MIN 1 7/8" MIN. REVISIONS SEPARATION EDGE DISTANCE REv DESCRIPOON DATE APPROVED CONCRETE/MASONtY " . 6 n•'. '.. BY OTHERS e' n °' ; " ,•• 1 1/4" MIN. 1 1/4" MIN. :'• ,'a •;•. °a. •: .' .• EMBEDMENT • MAX. e• •� ;• i a•. •.n EMBEDMENT 1/4" OPTIONAL 1X BLCK •' _T SHIM SPACE SEE.NOTES 3 -7 SHED 1 T-7- o 1 7/8" '' INTERIOR BACKER ROD 1/4" MAX. MIN. '• °y & APPROVED SHIM SPACE EDGE SEAUNT DISTANCE s• •a • o 1/4" TAPCON v o a • r NOTES: . EXTERIOR 1. INTERIORAND EXTERIOR FINISHES,BYOTHERS, ' NOT SHOWN FOR CLARITY. 4 7/16" 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE MIN a DESIGNED INACCORDANCE WITH ASTM E2112 SEPARATION FILI IEINTERIOR •• •. EXTERIOR 1/4" TAPCON A.I. . . . 1/4" TAPCON CONCRETEB OTHERS BACKER ROD & APPROVED SILL TO BE SET OPTIONAL 1X BUCK SEALANT u IN A BED OF SEE NOTES 3-7 JAMB INSTALLATION DETAIL APPROVED SEALANT SHEET 1 CONCRETEMASONRYINSTALLATION BACKER ROD 1/4" MAX. SIGNED:06/14/2017 & APPRP/ED SHIM SPACE SEAANT 111111117// MI 650WESTMARKETSTREET \```J) IR'L0 ,,���i GRATZ, PA 17030 `r�•��GENS ."9,1+�� OPTIONAL 1X B1CK ° a+ j• ° �•, ° ,• .''a�' ° 1 1/4" MIN SERIES 120/130/140 ALUMINUM SLIDING *• 1 0,.661 *T: SEE NOTE 3 - 7 a" ' •' • ' a •• .•'. EMBEDMENT GLASS DOOR - IMPACT w,a, i/��V(( ra` •• STATE OF •<v SHEET 1 .. .' ; a� a '• 3 TRACK FINLESS INSTALLATION DETAILS CONCRETE MASQIRY • �� '.' a ' • DRAWN: oWD NO. REV BY OTHERS °4 7/16" MIN 1 7/8" MIN sc.S. �� O8 s03�086 SEPARATION EDGE DISTANCE NTS 04/13/17 10 OF 24 VERTICAL CROSS SECTION L ROBERTOLOMAB P.E. Luis R. Lomas P.E. CONCRETFJMASONRYINSTALCATION 1492WOODFORDRDLEwIsvLLLE,PCz7Dzs FL No.: 62514 434.668-0609 ffiomas@hfomaspe.com • '3 � ' 2 3/16" MIN 1 7/8" MIN. REVISIONS SEPARATION EDGE DISTANCE r REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY " ° °�''•a•° •. •°�. BY OTHERS ,a• • , ' : 1 1/4" MIN. EMBEDMENT 1/4" MAX. CFTIONAL 1X BUCK . ° EMBEDMENT SHIM SPACE SEE NOTES 3 — 7 SHEET 1 _� e 1 7/8" r INTERIOR BACKER ROD 1/4" MAX. MIN. eV. & APPROVED SHIM SPACE EDGE SEALANT DISTANCE ►• ••� •: .. 1/4" TAPCON 2 3URATION .'., MSEPA : '! EXTERIOR .1/4" TAP INTERIOR CONCRETE/MASONRY BY OTHERS EXTERIOR OPTIONAL 1X BUCK BACKER ROD SEE NOTE 3 - 7 & APPROVED ri �3 SHEET 1 SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION 1/4" TAPCON SILL TO BE SET NOTES: IN A BED OF 1. INTERIOR AND EXTERIOR FINISHES,BYOTHERS, APPROVED SEALANT NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 BACKER ROD 1/4" MAX. SIGNED:06/14/2017 & APPROVED SHIM SPACE SEALANT MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET ��\\J\5 OPTIONAL 1.X BUCK —� GRATZ, PA 17030 = ��SF,S'� SEE NOTESHEET 1 ° '°' + • �• •°' 1 1/4" MIN SERIES 120/130/140 ALUMINUM SLIDING *• 0 61 * . EMBEDMENT GLASS DOOR — IMPACT ° a e 2 TRACK FLANGE INSTALLATION DETAILS TAT c uF e.' • ., �°.. •, .'°' ° DRAWN: DWD NO. REV �• <O R\DP CONCRETEBHERS MAS ° •,°' R.S. 08 -03086 — �VA�1�� �`\ 2 3/16" MIN 1 7/8" MIN S"LE NTS DATE 04/13/17 SMEET 16 OF 24 SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION LROBERTOLOMASRE, Luis R. Lomas P.E. CONCRETEAMASONRY INSTALLATION au-Os a-0609 na S WMB5Pe n FL No.: 62514 VI 9- BCIS Home I Log In i User Registration Hot Topic, Submit Surcharge Stats&Fads Publications I Contact Us ;r BCIS Site Map= Links Search F�ota b t Product Approval El USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail REIbEIVED t FL# FL28497-R2 J U L 15 5 ')019 9'9 Application Type Revision Code Version 2017 ST, LUCIa CaUnty, FO"Itl'in0 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC anis/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing 0 17 Certification Agency American Architectural Manufacturers Association Validated By Steven M.Urich,PE LUO-A Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.5.2/A440 2011 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 04/09/2019 Date Validated 04/09/2019 Date Pending.FBC Approval Date Approved 04/15/2019 Summary of Products Fl.# Model,Number or Name Description 28497.1 185 PW 73x61 Fin and Flange Frame Single Glazed Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL28497 R2 C CAC APC,(12118,J-21W07272.-02--IO2--47-- Approved for use outside HVHZ:Yes RDC7979.03-109-47-RO jQZ8-2-2jjLdf- Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+55/-55 10/28/2022 - Other.LC-PG55 Installation Instructions Ft R2 11 08-03292.pd Verified By:Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL28497 R2.AE-51-42-7A.-PAft Created by Independent Third Party:Yes 28497.2 185 PW 73x61 Fin and Flange Frame Insulated Glass Limits of Use Certification Agency Certificate Approved for use In HVHZ:No FL28497 R2 C CAC-APC(12"36 C7979.02,C7929.01-109-47- Approved for use outside HVHZ;Yes go 185 FXD.(102822)_.p!ff Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 10/28/2022 Other:LC-PG55,Wind Zone 3,Missile Level D.Glass is installation Instructions bedded in Pecora 896 backbedding. FL2fl497 R2 11 08-02947 2.pdf Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL28497 R2 AE 513781.pdf Created by Independent Third Party:Yes 28497.3 185 PW 73x61 Fin and Flange Frame Single Glazed Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL28497 R2 C CAC AP 12137)C7979.02,C7979-01-109-47- Approved for use outside HVHZ:Yes RO ISS FXD,.(jQg_82_2jjLdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 10/28/2022 Other:LC-PG55,Missile Level D,Wind Zone 3.Glass is Installation Instructions bedded in Pecora 896 backbedding. FL28497 R2 IT 08-02947 2.9ff Verified By:Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL28497- R2 AE 513781.pdf Created by Independent Third Party:Yes 28497.4 185 PW 37x78 Fin,Flange,Finless Frame,Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL28497 R2 C CAC PC(17762)18552,01-109-47-RO 185 Approved for use outside HVHZ:Yes FXD(020723),pdf Impact Resistant:No FL28497112 C CAC APC(178 5)1711.02-106-12-RO 185 - Design Pressure:+50/-63 PW( 072 Other:LC-PG50 Quality Assurance Contract"ration Date- 09/07/2023 Installation Instructions FL28497 R2.11._Qa:�03�38 pdf Verified By:Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL R2AE514376p Created by Independent Third Party:Yes 28497.5 185 PW 37x78 Fin,Flange,Finless Frame,Insulated Glass Limits of Use Certification Agency Certificate Approved for use In HVHZ:No FL28497 R2 C CAC APG(17938)1711,06-106-12-RO.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/07/2023 Design Pressure:+50/-63 Installation instructions Other:R-PG50 FL28497 R2 11. 08-03372,pd Verified By: Luis R.Lomas,PE PE-62514 ci-catco Dy inuepenuent Tnira Party:Yes Evaluation Reports FL28497 R2 AE 5:1.4164--p-df Created by Independent Third Party:Yes REVISIONS REV DESCRIPRON DA'E APPROVED NOTES: 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #8 SELF DRILLING SCREWS 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR REQUIREMENTS OF THE FLORIDA BUILDING CODE. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUBSTRATE-60CATE-AOUNCLiORS-�AS—SHOWN"1N—Et VATIONS A%D—Wl.5IALLATION DETAILS. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. FOR ANCHORING THRGH FRAME INTO MASONRY/CONCRETE USE 3/1 V7-fAPC0 TH 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1f2" WINDOW UNITS MUST BE SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION INSTALLATION INSTRUCTIONS, ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO EfAILS. MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE8 SMS OR SELF DRILLII-Z 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH 19. ALL FASTENERS TO BE CORROSION RESISTANT. MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, 20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR 6, WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: THE ARCHITECT OR ENGINEER OF RECORD. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. PROVIDED. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE D. METAL STRUCTURE: STEEL 16GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM SPACE OF 1/16" OR GREATER OCCURS, MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 21.GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWII OF SUSTAINING APPLICABLE LOADS. IN SHEET 2, 3 AND 4. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 15 FOR GLAZING DETAIL. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BO 03IS—R€GION€= FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS*----_ WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4 " MINIMUM EMBEDMENT }N70 SUBSTRATE. LOCATE ANCHORS AS-SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:0312612019 MI WINDOWS AND DOORS, LLC t1�ttLt?trrrr 650 W. MARKET ST. \\�J��R•�S;�t,Q�i GRATZ, PA 17030 185 PICTURE WINDONrL 1k•OTIATigilp 81 IMPACT 37" x 78"TABLE OF CONTENTS NOTESw . SHEET N0. DESCRIPTION DRAWN: OWC N0. REV �18RtD�:'G\' �� 2 ' 4 ELEVATIONS SCALE NTS DATE 03/12/19 OB SHEET 12 OF 15 i�fjsiQ�11,11P 5 — 14 INSTALLATION DETAILS L.ROBERTO LOMAS RE Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC27023 FL No.: 62514 15 COMPONENTS 434.888.0808 dtomweldomasm.mm REVISIONS REV-[ DESCRIPTION DAIS APPROVED 7��AME WIDTH- FR 37" FRAME WIDTH 14" 14" MAX MAX. ...... O.C. O.C. NOTES: .. X. - 344%4"X761/4' 3" MAX. 3" MAX. 3" MAX 1. D.L.O.SIZE. 003- AXCHARTa CHART#2 NUT with rlgld filfillersMAX kO.C. 14" Framb 14" Frame width On MAX D.C. Height 24.00 30,00 37.00 --r, fln) H&s jamb H&S Jamb H&S Jamb78" 78.. T '24.00 3 3 3 3 1 4 3 1 FRAME FOR N MBER OF FRAME / FOR NUMBER OF 30-00 3 33 3 4 3 ANCH RS REQUIRED HEIGHT — 3 HEIGHT SEE HART #2 ANCHORS REQUIRED 31160 3 4 3 4 4 4 SEE CHART #2 4200 3 7— 3 4 4 4 4&00 3 4 3 4 4 4 64.00 3 5 3 6 4 5 60.00 3 5 3 6 4 5 16&00 3 6 3 6 4 6 Y 7200 3 6 3 1 6 4 6 00 S' AX.00 78 00 3 T 3 7 r 185 FIXED WINDOW 185 FIXED WINDOW DESIGNER EXTERIOR VIEW EXTERIOR VIEW FLANGE&FINLESS INSTAL Al FLANGE&FINLESS INSTALLATION WITH FILLERS WITH FILLERS DESIGN PRESSURE RATING IMPACT RATING +50.01-63.OPSF LARGE MISSILE IMPACT MISSILE LEVEL 0,WIND ZONE 3 37"X 78-UNITSHOWN.OTHER SIZES APPROVED AS LONG AS FRAME AREA DOES NOT EXCEED 20.04 FP SIGNED:0312612019 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 185 PICTURE WINDOW 0 0 IMPACT 37" x 78" WITH FILLERS OTAT4 FLANGE & FINLESS ELEVATIONS E OF 4*�Qzz' DRAWN: g - I R DWG NO. '%-,%4:F ZORM C- A.R. 08-03372 NN :N SCALE NTS DATE 0.3/12/19 IsI'l-3 OF 15 L ROBERTO LOMAS AE Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NCZ7023 FL No.: 62514 "Illy REVISIONS REV DESCRIPTION ONE APPROVED 2" MIN, EDGE DISTANCE 1 1/4" MIN. CONCRETE/MASONRY BY OTHERS 4 EMBEDMENT 4 4* 4 'A 4 4 .4 j 1 1/4" MIN. OPTIONAL 1X BUCK 4 �4 EMBEDMENT SEE NOTES 3 — 7 SHEET 1 CONCRETE/MASONRY BY OTHERS 1/4- MAX. SHIM SPACE BACKER ROD 1/TM A X. OPTIONAL IX BUCK ROD APPROVED SHIM SPACE SEE NOTES 3 — 7 SEALANT SHEET 1 F INTERIOR 3/16" TAPCON 3/16- TAPCON EXTERIOR INTERIOR 3/16" TAPCON 2" BACKER ROD MIN' & APPROVED EDGE SEALANT DISTAt CE EXTERI OPTIONAL 1X BUCK SHIM SPACE BACKER ROD PER ROD PRO �VED SEE NOTE 3 — 7 APPRO D TAPCON SHEET 1 SEALANT CONCRETE/MASONRY JAMB INSTALLATION DETAIL BY OTHERS -4 1 1/4- MIN. CONCRETEIMASONRY INSTAUATION 4, 1MBEDMENT 4 4. SIGNED.0312612019 2" MIN.. \Iffilli.11111 EDGE DISTANCE MI WINDOWS AND DO S LLC ' S VERTICAL CROSS SECTION T. R,.'L 0 GRATZ I coNcRETEVAsONRYINSrALLATION 11�ET S 185 PICTURE WINDOW 0 51 •*i=�' IMPACT 37" X 78" FLANGE INSTALLATION DETAILS WITHOUT FILLERS • AT OF REIF '40R\D DWO NO, NOTES: 1 NA 1.INTERIOR AND EXrERIOR FINISHES,BY OTHERS, A. 08-03372 NOTSHOWN FOR CLARITY 2.PERIMETER AND JOINT SEALANT By OTHERS TO BE SCAIE NT DATE 03/12/19 [SHEET 6 OF 15 1J111IIN DESIGNED IN ACCORDANCE WITH ASTM E2112 ----L—ROBERrO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODF010'R VIUE NC2 FL No.: 62514 434-688-0609 dto Alf"