Loading...
HomeMy WebLinkAboutProduct Approval, Mullion r. BCIS Home . Log In t User Registration Hot Topics Submit Surcharge i Stats&Facts Publications F ta�.t Vp BCIS Site Map Links Search I � 'da l.r;L►/ ED OUSER: Public User Product Approval JUL 17 1019 Permitting Department X St. Lu Pr Approval Menu>Product or Application Search>Application List>Application Detail C`�COt!,ity n i FL# FL9520-R7 ` O—� Application Type � Code Version 2017 Application Status Approved Comments Archived "g Product Manufacturer Custo�Windo s Inc. Address/Phone/Email 1900 SW 44th Avenue !, Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc ( , Authorized Signature Kevin Pine v kpine@cws.cc Y-� Technical Representative . ]ay Lathrop - Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE 25 Validation Checklist-Hardcopy Received Certificate of Independence FL9520 R7 COI EvalReoort8366.�df Referenced Standard and Year(of Standard) Standard Year AAMA 450-10 2010 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL9520 R7 Equiv FL9520 Eauivalencv_pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/29/2017 Date Validated 10/02/2017 Date Pending FBC Approval 10/05/2017 Date Approved 12/12/2017 Summary of Products L# Model,Number or Name Description 9520.1 3"Alum.Tube Mullion 3"Alum.Tube Mullion, Horizontal&Vertical, Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use' HZ:Yes FL9520 R7 II CWS-836B.� Approved for e o e HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resis ntL_Y s Created by Independent Third Party:Yes Design Press e: N/A Evaluation Reports Other: Large Missi a Impact; See Installation Instructions and FL9520 R7 AE EvalReport836B.p.Of Evaluation Report for complete list of Limitations and Created by Independent Third Party:Yes Conditions of Use. 9520.2 4"Alum.Tube Mullion 4"Alum.Tube Mullion, Horizontal&Vertical, Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-837B.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions and FL9520 R7 AE EvalReport837B.pd Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.3 5 1/2"Alum.Tube Mullion 5 1/2"Alum.Tube Mullion, Horizontal&Vertical,Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-838B.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions and FL9520 R7 AE EvalReDort8386.pfif Evaluation Report for complete list of Limitations and Created by Independent Third Party:Yes Conditions of Use. sack Next i Contact Us::2601 alatr Stone Road,Tallahassee FL 37399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Sppydght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one,The ematis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ,. ® atfk ........................................... ..................._.....__......................................._... .....+1�.. ..._... ..................................................................................... 3" PVC MULL BAR - LARGE MISSILE IMPACT GENERAL NOTES: 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH V yDOW SYMMS SHOWN w/DIFFERENT OPTIONS THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 15 RATED FOR WIND ZONE 4 MISSILE LEVEL E. 1900 1900 SS FLORIDAW 44TH AVE. D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. OCA34474 WWW.CW OCC 2.CONFIGURATIONS(SEE SHEETS 2-3):VERTICAL OR HORIZONTAL. 3.SEE MULLION CHARTS FOR MAX.DESIGN PRESSURES AND LENGTH. 3" PVC r (REFER TO SHEETS 2-3) MULL BAR \ 4.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE IMPACT DESIGN OF THIS PRODUCT.SEE SHEETS 9-10 FOR ANCHOR DETAILS. W INDLOAD O DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. J Z 5.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. H 0 w p ¢F p 6.DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER w z O z Itt Z W loelo�IK g DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. LL g �w z O�� ANCHOR CLIP ANCHOR CLIP Z Z x a a'W O O A c 7.DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT 0 �(D�U a H N a 6 7 APPROVAL. TO THE MULLION.WINDOWS MUST BE APPROVED UNDER SEPARATE 0 o Z U�Z j U CD O B O O >- «,2 0 LL Z g 8.RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY cr g O r F-r Z APPLICABLE LOCAL LAWS,BUILDING CODES,ORDINANCES OR OTHER SAFTEY aO U�}j 3 O n REQUIBUILDREMENTS OWNER RESTS SOLEY WITH CONTRACTOR,THE ARCHITECT,ENGINEER OF RECORD, w Z U w 0 00 w U)F I-- a. xa xo�co 9.SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS a F~a it?:a DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY X X X CUSTOM WINDOW SYSTEMS,INC.AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM. ����s;�fy�!rUr Q Q Q 10.VERTICAL MULLED UNITS MAYBE MULLED INDEFINITELY AS LONG AS THE SINGLE ``�`,� 1dRE41!Pr�rir UNIT W IDTH AND HEIGHT ARE NOT EXCEEDED,AND MULLIONS ARE ANCHORED AS �p` �.•yVGE.Ng r! pN SHOWN HERE IN. G� F E D •.�? Na 5B2fl1 ',�'�+�: 10 10 9 g ANCHOR CLIP 11.HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. =o' ;dt� EXAMPLE HORIZ/.VERT.MULLION .9 t STATE OF •(U FOR SECTION VIEW ONLY B; 4* ANCHOR CLIP hwh �OPjEk'� •`` Lucas Turner 2017-09-28 Z O O 07:12+20:00 9/26/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 I X I X I SHEET DESCRIPT N: I I I TABLE OF CONTENTS GENERAL NOTES AND ELEVATIONS GENERAL NOTES&ELEVATIONS...............1 oRAwN av: oarE: DP CHARTS.................................................2-3 ADE 09/27/12 BOM&EXTRUSIONS.....................................4 ANCHOR CLIP EXTRUSIONS.................................................5 DWG#: REV.: SECTION VIEWS.........................................6-7 EXAMPLE VERTICAL MULLION FOR CWS-836 B CONFIGURATIONS&ANCHOR NOTES.......8 PVC WINDOWS FOR SECTION VIEWS ONLY SCALE: INSTALLATION DETAILS..........................9-10 SHEET 1:25 1 OF 10 Design Pressure Chart(PSF)for NON-INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 clips using four(4)#10 Screws Into WOOD or METAL Dr 3/16"ITW Tepcons or ELCO ULTRACONS into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. (Ss •M OPENING SIZE in. WINDOW SYSTEMS 39 45 51 57 63 69 75 318 81 87 93 99 107 3/8 114 120 126 132 138 145 3!8 1900 SW 44TH AVE. 37 80.0 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 OCALA,FLORIDA 34474 c 42314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 WWW•CWS.CC = 483/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 531/8 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 3„PVC Z 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 66.0 n 63 80.0 80.0 Lu 80.0 80.0 80.0 80.0 80.0 B0.0 78.9 76.6 74.8 72.5 65 0 65 0 " : MULL BAR j 65 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0h x I IMPACT 68 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 1 65.0 65.0 63.5 : _ ; E MR, 72 65.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7 a, %- - =i:i= Design Pressure Chart(PSF)for INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 clips using four(4)#10 Screws into WOOD or METAL or 3/16"ITW Tapcons Into SOLID CONCRETE or WOOD,or 1776 clips with six(6)#10 Screws Into WOOD or METAL or 3/16"rTW Tepcons Into SOLID CONCRETE or WOOD per each end of mullion.HOLLOW or GROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. ((/ • OPENING SIZE in. WINDOW SYMMS 39 45 51 57 63 69 75 318 81 87 93 99 110 318 114 1 120 126 1 132 138 145 318 1900 SW 44TH AVE. 37 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 OCALA,FLORIDA 34474 c 42 314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 WWW.CWS.CC = 483/4 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 531/8 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 3"PVC W57 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 4B.1 MULL BAR 63 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.4 47.3 . . 68 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.6 IMPACT 72 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 45.4 44.0 _y;. 75.375 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 46.8 44.0 40.0 N. ,z ; ¢ z ¢Z o 06 DP CHART IS FOR: z Z Q z W t z w INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): g LL F w 3 z OF It�iE z ZMM<MLUOO 1522 CLIPS O O r O UI)-(4)#10 SCREWS INTO WOOD or METAL O U(0 I-0-F~D: en Z -(4)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD z p 0M- -ow -(4) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK } ¢ LL w p Oz w0 Z �¢Or� Z 1767 CLIPS �o�}2 S 2 -(6)410 SCREWS INTO WOOD or METAL w w o W w oo w u)w (6)3116"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD o -(6) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK p w F--O a Oz Y _ wW y cL �y�rit><.Itb aov �gDREW?'4,� ♦� P.a" t TWIN/TRIPLE HORIZONTAL MULLION VERTICAL MULLION --- -- z ISINGLEI j qTWIN IORI O I TR IPLE I --- -- I UNITS I �� BELOW II I I 9/26/2017 OPENING SIZE MULL LENGTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPT ON: NOTES: DP CHART 1.THE MULL BAR IN FOCUS FOR ANY GIVEN INTERSECTED MULLS CONFIGURATION IS SHOWN IN BOLD. 2.AN INTERSECTED MULL BAR HAS OTHER MULL DRAWN BY: DATE: BAR(S)ATTACHED TO R(SHOWN IN DASHES) ADE 09/27/12 THROUGH THE USE OF MULL BAR CLIPS.AN INTERSECTED MULL BAR WILL ALWAYS BE DWG REV.: #: ATTACHED TO THE SUBSTRATE AT BOTH ENDS. CWS-836 B 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED SCALE: SHEET TO THE SUBSTRATE AND OTHER MULL BARS. 1;1 3 OF 10 ITEM PART# DESCRIPTION 'T"MULLBAR CLIP "L"MULLBAR CLIP (( •L�%� 1 H-1758 13/8"x 3"MULLION TUBE LINE ITEMS NOT USED: FRAME TYPE OPENING F-1522-XXX F-1767-XXX 2 910 OR#12 HEX WASHER HEAD TEK SCREW•(see note below) 5-6,12 NEW F-1522-013 F-1767-001 3 #10 x 1 1/2",PANHEAD PHILIPS ZINC FLANGE WINDOW SYSTEMS 4 #10 FLAT WASHER RETRO F-1522-006 F-1767-001 1900 SW 44TH AVE. 7 S-1897 MULLION CLIP FIN NEW F-1522-013 F-1767-004(L&R) ww CWS.CCA34474 8 SEALANT RETRO F-1522-013 F-1767-004(L&R) 9 S-1895 DRIP CAP NEW NOTRECOMMENDED F-1767-001 10 S-1896 FLANGE ADAPTER BOX RETRO F-1522-006 F-1767-001 3"PVC 11 S-6018 MULLION INTERIOR COVER 13 P3486 MULL BAR CAP MULL BAR 14 1 F-1522-013 3"SLOTTED NEW CONTRUCTION FIN MULL CLIP IMPACT 15 F-1522-006 13"SLOTTED T-CLIP 16 F-1767-001 L-ANGLE 3-MULL CLIP,STANDARD 17 F-1767-004L L-ANGLE 3"MULL CLIP,FIN,LEFT < owo o ¢IWF--0 p 18 F-1767-004R L-ANGLE 3"MULL CLIP,FIN,RIGHT w z 0? w t z i'u_ 19 #10 HEX WASHER HEAD TEK SCREW O ¢co�j z}z O a m 20 #10 FH TEK SCREW O z m O .O 0 •USE WOOD SCREW SIZE(#10 OR#12),SPECIFIED IN W INDOW UNIT APPROVAL DOCUMENT 0 U U z D- cn as 0 Z— —?F7co Z O0puj DU— i--�u_oZpOu 0 1314" 1/2'7 _ 17/16° 17116" S2'OwF-F=-Z- 11/1fil" I 9= Q Mgy�U— !/1 7/16" � 1/2'LU F- ppF-}0�0t- W O=Vlow55w 11 1 1/4' 10 9 7/16" 7/16, (L co d O 0 W F- L--1/16" L 1/16' 1/1 fi" o_ = o:O U) p wF O ax�Y DRIP CAP S-1895 1 13/16' (1 15/16") 1 13/16" 3/8' = a K�w co MULLION INTERIOR 1 3/16' G. F- a COVER S-801B FLANGE ADAPTER S-1896 2 7/16„ L 111/16" (1718"1 `,`* ittpe�t�*�' F�13I8"moi O 114"(TYP 41/8" 4 L1RE41r _ TOP VIEW 2 7116" 15/16' � �*� * `* 213116"L 118" 1'57 t STATE OF •�: _21/16'. s/8" %O"yR" 4•P�V+r 1 3/4' 1 3I8I I O "�I 1 3/16' 2 3/16' 3"MULLBAR H-1758 7�v fll— 1/8' MULLION CLIP S-1 B97 1a9/26/2017 IL- 4 7/8"—moi 21/4" LUCAS A.TURNER,P.E. ' F-1522-006FL A#58201 RAA 1/8^ RETRO/FLANGE CLIP 1239 JABARA AVE. LNORTH PORT,-1 34288 � PH.941-380-1574 4 722� SHEET DESCRIPT N: F-1522-013 NEW CONSTRUCTION/FIN INSTALLATION BOM AND EXTRUSIONS A SCORE,BEND AND BREAK TO REMOVE FIN FOR FRAME / DRAWN 8Y: DATE: ATTACHEMENT TO MULL BAR ADE 09/27/12 DETAIL A DWG#: REV.: TYP.FIN FRAME 3:1 CWS-836 B SCALE: SHEET NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1:2 4 OF 10 FRAME TYPE OPENING 'T'MULLBAR CLIP "L"MULLBAR CLIP F-15 2 XXX F-1767-XXX ((� • NEW F--1522-013 F-1767-001 FLANGE WINDOW SYSTEMS RETRO F-1522-006 F-1767-001 1900 SW 44TH AVE. FIN NEW F-1522-013 F-1767-004(L&R) OCALA CWS.CCA 34474 RETRO F-1522-013 F-1767-004(L&R) NEW NOT RECOMMENDED F-1767-001 BOX RETRO F-1522-006 F-1767-001 3"PVC MULL BAR IMPACT Z- 3 <Z� 17 18 J ❑WO <F--azW Z W❑ ❑ ZtOnZ}O�Zm IL Hw�ZF—km2 Z Z2m< O OroU�_�� F--2314' 21/4^ ❑ Z-j�?F�(A Z OZOUjZZ)U— < F=—LL�0OD-Z Q�?}OWF,FZ cd O_ It 15/8" 123/4'1 27116" K Z�w�p-jNIW— a co I-- Q. WF=-0 WZ2of �y 318"(2X) D- F- a a 7/16"THRU(TYP) 114'THRU(TYP) �I 1/2^ ��►��Y�M}REyitrf°i OUTSIDE ���� L 1/4"(TYP) 7/16"(TYP) No 58201 .ti'. 318„ O 3/8" 11c t 110% $Vre CF ",Z 1 s/a• I2 314"1 1518" r�F t0 Ft Sc�:� ��.*� 16 L CD s lie 9/26/2017 v2" vz° LUCAS A.TURNER,P.E. 2 314" —23/4 "L•ANGLE 3'STANDARD MULL CLIP-F-1767-001 FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 'L"ANGLE 3•MULL CLIP,FIN(LEFT)F-1767-004L "L'ANGLE 3'MULL CLIP,FIN(RIGHT)F-1767-004R PH.941-380-1574 OUTSIDE SHEET DESCRIPTION: I EXTRUSIONS DRAWN BY: DATE: ADE 09/27/12 DWG#: REV.: CWS-836 B SCALE: SHEET 1:2 5 OF 10 i ��. 1900 SW 44TH AVE. OCALA,FLORIDA 34474 i WWW.CWS.CC 3"PVC MULL BAR SEAL BEHIND FLANGE O SEAL BEHIND FLANGE D PRIOR TO ATTACHING 0 APPLY SEALANT ALONG FULL LENGTH OF WINDOW FRAME IMPACT PRIOR TO ATTACHING TO MULLION 2 2 TO MULLION 2 II GROOVE PRIOR TO ATTACHING 2 g 1 OVER 9 1 1 Q Z 3 ¢Z3 11 11 11 11 Z W-jO ¢I-❑W FIN MUST BE REMOVED w Z O Z �t Z H O WHERE WINDOWS ! ❑ ¢N3}0�3m CONNECT TO MULLW Z Z Z F-3 x O Oro ¢_�� U U(n~zaUa ❑ z—cl) Z ODUui 7U— I } ¢30w—Oxo? 2a r-F t:z wx A VERTICAL/HORIZONTAL MULL BAR SECTION w O❑ v}i o w w w �A\HORIZONTAL MULL BAR SECTION HORIZONTAL MULL BAR SECTION LL cn w O w U)w 6 FLANGE FRAME WINDOW s FIN FRAME WINDOW a BOX FRAME WINDOW a ? O wI-a �x�� a 3w a I - '%%yyss�t,� rjrr i ,s+ Nt?REW 11 1 2 APPLY SEALANT ALONG FULL Rr`G� �G".d1E��t '''Q��'S 11 1 2 LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING DRIP ,►,-�: No 58201 ADAPTOR � ; O i1f' $TAre op d'4a FIN MUST BE REMOVED 1 'r�'4'F`a<p A WHEREWINDOW5 - ` CONNECT TO MULL 9 �ir'�h Of4A'+���s�'` i DETAIL A Z 9/26/2017 SEAL BEHIND FLANGE (SEE SEE DETAIL B) LUCAS A.TURNER,P.E. SEAL BEHIND FLFL PE#58201 ANGE 10 (SEE DETAIL B) PRIOR TO ATTACHING APPLY SEALANT ALONG FULL - TOORTOI LENGTH OF MULLBAR GROOVE ATTACHING TO MULLION 1239 ABARAAVE. PRIOR TO ATTACHING FLANGE NORTH PORT,FL 34288 ADAPTOR B VE lCAL MULL BA SECTION B VERTICAL MULL BAR SECTION 1 PH.941-380-1574 6 FLANGE FRAME WINDOW s FIN FRAME WINDOW f L SHEET DESCRIPTION: SECTION VIEWS MULLS L � DRAWN BY: DATE: ADE 09/27/12 DWG#: REV.: 10 DCWS-836 B DETAIL B SCALE: SHEET 1:2 6 OF 10 1 1 18 \S��UQHUJ L4lU/�� � WINDOW SYSTEMS 1900 SW AVE. OCALA,F OTRIDA 34474 WWW.CW S.CC A : 3"PVC Q 0 MULLBAR IMPACT I- O W O H e w OZ A 1 O OF=-Oa¢ OO W SECTION VIEW A-A O OLorpza-Prn(L TOP VIEW °z ozucriZ�V� FIN FRAME ¢ F-,200i'-Z >- flouipmoZ. w 0owc}i�owv0—iw LL 0�U) O Lu w=may z T F- a ��a 5"MULLBAR(H-1760) (SEE SEPARATE APPROVAL FOR 2) 4"MULLBAR(H-1759) O APPROPRIATE DP CHARTS) Q (SEE SEPARATE APPROVAL AFOR APPROPRIATE OP CHARTS) `�, 2 No J?F 3Ja SB201 t;��1% p 110t $TATE OP r#J 11/16"MAX. DISTANCE SEE NOTE 1 7 11/�GE DISTANCE ~'� �'-4 0 A t} SEE NOTE 1 7 1 SEE NOTE 1 7 11116"MAX.EDGE DISTANCE ! C9'............S'`�t ! ;+lptlilllittt 11 19 19 SEE NOTES 1 8 2 SEE NOTES 182(1 EAJCLIP) 1 19 SEE NOTES 1 8 2 SEE NOTE 4 0 (1 EAJCLIP) SEE NOTE 4 0 (1 EAfCLIP) 9/26/2017 SEE NOTE 4 0 C 4"HORIZ.TO 3"VERT.MULLBAR SECTION C 3"HORIZ.TO 3"VERT.MULLBAR SECTION LUCAS A.TURNER,P.E. C 5"HORIZ.TO 3"VERT.MULLBAR SECTION 7 FLANGE FRAME WINDOW 7 FLANGE FRAME W NDOW 7 FLANGE FRAME W NDOW FL PE#58201 1239 JABARA AVE. NOTES: - - NORTH PORT,FL 34288 PH.941-380-1574 1. SLIDE CLIP INTO LOCATION AND SECURE WITH ITEMS 19(CITY 1)AND 20(CITY 1),AS SHEET DESCRIPTION: SHOWN ABOVE. SECTION VIEWS 2.PRE-DRILLED HOLES(THRU HN CLIP 1897),BY THE INSTALLER, MULL INTERSECTIONS MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE OF 9/32'AND A MINIMUM CENTER TO CENTER SPACING OF 1/2". DRAWN BY: DATE: 3.THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS, ADE 09/27/12 REGARDLESS OF ORIENTATION(i.e.,HORIZONTAL OR VERTICAL).THE FULL LENGTH DWG#: REV.: MULL MUST BE THE SAME DEPTH,OR GREATER,THAN THE INTERSECTING MULL. CWS-836 B 4.INTERIOR MULL ANCHOR ATTACHMENT SCREW THRU VERTICAL MULL INTO MULL SCALE: SHEET CLIP. PRE-DRILL PILOT HOLE THRU ALL MATERIAL. 1:2 7 OF 10 I NOTES: �Q 1.THE MULL BAR IN FOCUS FOR ANY GIVEN (l 77/o j/11TN1f7��/�{/d CONFIGURATION IS SHOWN IN BOLD. �L4L4til1(41�1/UU(!� TWIN TRIPLE TRANSOM OVER TWIN TRANSOM OVER TRIPLE 2.AN INTERSECTED MULL BAR HAS OTHER MULL WINDOW STSnMS VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION BAR(S)ATTACHED TO IT(SHOWN IN DASHES) 1900 SW 44TH AVE. r THROUGH THE USE OF MULL BAR CLIPS. AN OCALA,FLORIDA 34474 INTERSECTED MULL BAR WILL ALWAYS BE WWW.CWS.CC ATTACHED TO THE SUBSTRATE AT BOTH ENDS. 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED r TO THE SUBSTRATE AND OTHER MULL BARS. w w 3••PVC r= W W MULL BAR tIMPACT I I I I I II L - I L < — �Wo Fes— OPENING SIZE--^i OPENING SIZE Fes- F� OPENING SIZE" OPENING SIZE Fes- Z W_j O <F-❑W ❑Ld ZoZ}ZOLYZm O OI=Oa<WOO HORIZONTAL MULLION U O w w Z D TWIN/TRIPLE ❑ Z- -?F�U) TWIN TRIPLE TWIN[TRIPLE VERTICAL MULLION r Z o0=1�/j-7 0- HORIZONTAL MULLION HORIZONTAL MULLION HORIZONTAL MULLION < F- 20 O u-Z <30F�tz°- 0 (DO OPENING -- -- O ZcowyOw�� L SIZE z Z �SINGLE� a =a O m z y J aZ. I R - =~a � w� o ITRIPLE] a a a z —— —— UNITS o �BELOW� L I I y{1ilEYiflff I--MULL LENGTH ---II I Ny�rotPh'0`RE �-MULL LENGTH MULL LENGTH - OPENING SIZE MULL LENGTH--I ��1'�@,.'N,4GEl,Q�yyG>r :moo; srArle o� :rfu�•` NOTES: 1.AT MULLION LOCATION,ATTACH WINDOW UNIT(S)TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS.IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNITAPPROVAL z� DOCUMENTS,FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE,USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE(#10 OR#12)AS THE ................ WOOD SCREW INDICATED IN THE WINDOW APPROVAL.TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE(3)THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 9/26/2017 2.MULL CLIP INSTALLATION ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 9. LUCAS A.TURNER,P.E. 3.ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED FL PE#58201 WOOD MUST BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. NORTH PORT,FL 34288 4.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE PH.941-380-1574 MINIMUM SPECIFIED IN TABLE 1,SHEET 9. SHEET DESCRwT N: 5.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1X BUCKS CONFIGURATIONS AND ARE OPTIONAL. ANCHORAGE NOTES 6.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE-DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5. DRAWN SY: DATE: ADE 09/27/12 7.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-836 B 8.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAIWOMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(E)CTERIOR DOORS) 1:1 8 OF 10 i I YVINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 3"PVC MULL BAR IMPACT RETRO FIT 'L"ANGLE MULL BAR CLIP MULL BAR CLIP TWO REQ'D PER EACH END OF MULL ¢ Z � Q Z F O W O S cd F p MULL BAR MULL BAR III O z 0 Z}O It-tz m INSTALLATION ANCHOR ..P - - ` INSTALLATION ANCHOR O O U)I-Z d I--U)a I SEE TABLE 1 SEE TABLE 1 p Z-�-Z F O U SEALANT ALONG -- _=_ = Do ADD STRUCTURAL ELEMENTS SEALANT ALONG - `__- '�• ADD STRUCTURAL ELEMENTS S -Z U Z LL U .._;...,;.w.. , �^ AS REQ'D TO MAKE LEVEL FOR AS REO'D TO MAKE LEVEL FOR O Z OUTSIDE EXPOSED --'— OUTSIDE EXPOSED - — } O F 2- ti., EDGE BY INSTALLER MULL BAR EDGE BY INSTALLER MULL BAR PERIMETER SEALANT PERIMETER SEALANT w 0 O x O W O W BY INSTALLER MN.EMBEDMENT BY INSTALLER MIN.EMBEDMENT a z=a 0 p � INSIDE AND OUT SEE TABLE 1 INSIDE AND OUT SEE TABLE 1 O W H 0 W 2 a a Luba SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 MIN.EDGE DIST. 511sttlift MIN.EDGE DIST. SEE TABLE 1 ¢tib g�REW+t!+i SEE TABLE 1 ��� ['"�•.+..«„ y` �It D VERTICAL SECTION E VERTICAL SECTION �yc�.4GE.N�"*.,v-� 9 TYPICAL FLANGE(RETRO FIT)ANCHORAGE 9 TYPICAL FLANGE("L"ANGLE)ANCHORAGE ,•,T,y",r + F '�'�tl�iw HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION :�, Na 5B2D1 ,� G"31 t STATIC F +4 ............... 9/26/2017 NOTES: LUCAS A.TURNER,P.E. 1.BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. FL PE#58201 _- TABLE 1:APPROVED MULL CLIP INSTALLATION FASTENERS 1239 JABARA AVE. SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. 2.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1" 3" AFTER INSTALLATION. PH.941-366-1574 CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1-3/4" 1. 3. N: 3.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW HOLLOW or GROUT-FILLED CMU(ASTM C-90) 1/4"ELCO ULTRACON 1-1/4" 2-112" UNIT AS NEEDED. INSTALLATION DETAILS 2XMN.SOUTHERN PINE ITW TAPCON E(G=0.55) 1-3/8" 7/8" 4.FOUR 4 ANCHORS REQUIRED PER "MULL CLIP,SEE SHEETS 2�. FLANGE OR ELCO ULTRACON THREE(3 "T )ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. DRAV/N BY: DATE: 2XMN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-318" 7/8" ADE 09/27/12 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HLTI KWIK-FLEXOR IiW FULL THREAD 7/16' 5.SEAT MULLION TIGHT TO MULL CLIP. DWG N: REV.: (33 K51 YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" CWS-636 B 1/8"ALUM.(6063-75 MIN.)OR #10 GRADE 5 SELF TAPPING/ FULL THREAD 8.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1:2 9 OF 10 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 3"PVC MULL BAR IMPACT a z ¢Z� RETRO FR 'L'•ANGLE CLIP 1= O 111 0 10 W pp MULL BAR CLIP TWO REO'D PER EACH END OF MULL z Z O z <L z~ OQco OIY�m F-W3}ZF-?r22 MULL BAR MULL BAR z z F O a¢W 0 0 F60_Ftj d — ��m — o Z-cnZz 1i ?: .I :: INSTALLATION ANCHOR ;(`= — INSTALLATION ANCHOR Q 0 Z O ZO p U SEE TABLE 1,SHT 9 SEE TABLE 1,SHT 9 <_—LL O 0 Z ooz� SEALANT ALONGE - - SEALANTALONGE �'— uJ LL O uj En FW- OUTSIDE EXPOSED OUTSIDE EXPOSED EDGE BY INSTALLER °o• EDGE BY INSTALLER °b;o, p W I-Q a 2 > 0 °O °.. 'o °• MIN.EMBEDMENT EXTERIOR FINISH •oJ,° _ MIN.EMBEDMENT a H a W EXTERIOR FINISH ..._ "' "' SEE TABLE 1,BHT 9 BY OTHERS • T - - --' SEE TABLE 1,SHT 9 IL OTHERS •:o <"' ....... ...,. ..oa.� PERIMETER SEALANT o c PERIMETER SEALANT BYINSTALLER BYINSTALLER INSIDE AND OUT ; INSIDE AND OUT �owOREw A* SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1,BHT 9 .:o• SEE TABLE 1,SHT 9 «„w��R ""Y,\�"�E b"•�+,"•.�.?c 5++' ^ MIN.EDGE DIST. MIN.EDGE DIST. ti v� No 58201 •',1'F F VERTICAL SECTION SEE TABLE 1,SHT 9 G VERTICAL SECTION SEE TABLE 1,SHT 9 ,�yj. * :,y 10 TYPICAL FIN(RETRO FIT)ANCHORAGE 10 TYPICAL FIN(°L"ANGLE)ANCHORAGE r rte« HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION ��y STATE OF 1,[40 r� 9/26/2017 LUCAS A.TURNER,P.E. NOTES: FL PE#58201 - 1239 JABARA AVE. 1.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 AFTER INSTALLATION. PH.941-380-1574 SHEET DESCRIPTION: 2.RECESS RETRO MULLION CLIP 3/8°MAX.FOR CLEARANCE OF WINDOW UNIT AS NEEDED. INSTALLATION DETAILS FIN 3.FOUR(4)ANCHORS REQUIRED PER"T•MULL CLIP,SEE SHEETS 2-3. THREE(3)ANCHORS REQUIRED PER"L°MULL CLIP,SEE SHEETS 2-3. DRAWN BY: DATE: 4.SEAT MULLION TIGHT TO MULL CLIP. ADE 09/27/12 _ DWG#: REV: 5.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW CWS-B36 B SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 12 1GDF 10