Loading...
HomeMy WebLinkAboutProduct Approval, Mullions (2) - - 1 i z 1/4/2019 Florida Building Code Online ° t(..) t� :}_1b•) �� .IMP t tF.??5I ! Pq• mag t {-eT Y f SCIS Home Loq 1n User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCiS Site Map Links Search ba JUL 18 2019 4 Product Approval fid•,- USER:Public User Permitting Department St. L_idc County product Agoroval Menu>Prooyct Productor Application Search>Application List Search Criteria Refine Search Code Version 2017 FL* 17472.1 Application Type ALL Product Manufacturer ALL Category . ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ae Iicatlons FL# T-,ypg Manufacturer Validated By Status FL17472-R3 Revision Eastern Architectural Systems Keystone Certifications,Inc. Approved Hillary FL*:FL17472.1 (717)932-8500 Model:HVHZ Clipped Aluminum Bay/Bow Mullion Description:HVHZ Clipped Aluminum Bay/Bow Mullion Category:Windows Subcategory:Mullions i *Approved by OBPP_Approvals by DBPR shall be reviewed and roHt€ed by the POC and/or the Commission it necessary. Contact Us::2601 walr Stone Road,Tallahassee FL 32399 phone:850.487-1824 The State of Florida is an AAJEEO employer,Qgitydght 2007-2013 State of Florida.::QQyaly Statement::Accessibility Statement;;Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts- 00 M El M Credit Card Safe i i i https://www.floridabuilding.org/pr/pr ap_isLaspx 1/1 f _ r 1/4/2019 Florida Building Code Online SCIS Home Log in User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Unla !Search bProduct Approval f.. USER:Public User Product ARRroyal Menu>Product or Aopiicotion Search>Qppjisation Llst>Apptleition Debt) i ' FL# FL17472-R3 Application Type Revision Code Version 2017 Application Status Approved "Approved by DBPR.Approvals by DBPR shalt be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft.Myers,FL 33912 (800)432-2204 Ext 4305 jffesher@eastemmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Timothy J.Hoard Address/Phone/Emali 10030 Bavaria Road Fort Myers,FL 33913 (800)432-2204 Ext 4314 thoard@eastemmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Keystone Certifications,Inc. i i� Referenced Standard and Year(of Standard) Standard Year AAMA 450 2010 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A 4 https:l/vruvw,floridabuitding.orgfprlpr app dU.aspx?param=wGEVXQu2DgtCUGgvjQiz6AvC%2bOtoUJS%2fT7NaD9SzMxXWfpyvfrXvrA%3d%3d i 1/2 � r 1/4/2019 I Florida Building Code Online Date Submitted 02/14/2018 Date Validated 04/04/2018 Date Pending FBC Approval Date Approved 04/11/2018 Summary of.Products_ I FL# Model,Number or Name Description 17472.1 HVHZ Clipped Aluminum Bay/Bow HVHZ Clipped Aluminum Bay/Bow Mullion Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17472 R3 C CAC EAS 622-104CAR.PDF Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/22/2021 Design Pressure:N/A Installation Instructions Other:See drawing set for mullion size,angle and design FL17472 R3,II PA-0004 SS 2018-02-14.pdf { pressure rating Verified By:Hermes F Norero,P.E.73778 I Created by Independent Third Party:Yes Evaluation Reports �) FL17472 R3 AE PER5504 SS 2018-02-14.pdf Created by Independent Third Party:Yes 17472.2 -- {HVHZ Clipped Aluminum Tube Mullion HVHZ Clipped Aluminum Tube Mullion-Vertical,Horizontal,T II and X Configurations Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17472 R3 C CAC EAS 622-101CAR.PDF Approved for use outside HVHZ:Yes FL17472 R3 C CAC EAS 622-102CAR,PDF Impact Resistant:Yes FL17472 R3 C CAC EAS 622-103CAR.PDF Design Pressure:N/A FL17472 R3 C CAC EAS 622-105CAR,PDF Other:See drawing set for mullion size,configuration and FL17472 R3 C CAC EAS 622-106CAR,PDF design pressure rating Quality Assurance Contract Expiration Date 07/18/2021 Installation Instructions FL17472 R3 II PA-0003 SS 2018-02-14,1df Verified By:Hermes F.Norero,P.E.73778 Created by Independent Third Party:Yes Evaluation Reports FL17472 R3 AE PER5505 SS 2018-02-14.pdf Created by Independent Third Party:Yes Contact Us::2601-Blair Stone Road,Tallahassee F 3t, 2399 phone:850-487-1824 The State of Florida Is an WEED employer,Qgyjght 2007-2013 State of Florida.:;PrIvaSy,Statement::Accessibility Statement::Refund Statement Under Florida taw,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850,487.1395.*Pursuant to Section 455,275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,RS.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.It you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please cildc ere-, a - Product Approval Accepts: i "R19 Pam EMS e rex ! 3 Credit Card Safe j I I I https://www.ftoridabuilding.org[pr/pr_app dti.aspx?param=wGEVXQwtDgtCUGgvjQiz6AvC%2bOtoUJS°/a2fT7NaD9SzMxXWfpyvfrXvrA%3da/e3d 2/2 Document Title: Doc No: FRM BI-02 Structural Performance Rev No: 7 P"O: 1 V,F-YSTONE7 Certification Authorization Report Required By: PRO B1-03 CAR& Product ID Number: 622 - 104.0 Issue Date: 1/16/2015 Revision Date: 2/16/2018 Expiration Date: 9/22/2021 Company Code: 622 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory; n accordance with the specified referenced standard.Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products,that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can beverified atwww.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model: Bay/Bow Aluminum Mullion 16341 Domestic Avenue Operator Type: Mull Fort Myers FL 33912 Config: No Reinforcement Max Width: See Table Max Height: See Table Referenced-Standard: Product Rating: AAMA 450-10&PA/TAS 201/2021203 See Appendix I Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-301 OW-1 OA Test Report Expiration:1 9/22/2021 Authorized Signature: Keystone Certifications, Inc. 2018.02.16 145 Limekiln Rd. Suite 10013 New Cumberland, Pennsylvania 17070 -05'00' Phone: 717-932-8500 11 :44:18 Fax: 717-932-8501 WWW.KEYSTONECERTS.COM j�,�Y".0 � A,p�pendix 1 CAR No:622-104.0 � '^ Expiration Date:9/22/2018 I i Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 ( Load Tables far the: 22.5 Degree Bay/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:22.5 Deg. -ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) Z8 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.D 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 i 60 200.0 200.0 200.0 175.3 159.1 149.0 144.1 143.5 141.6 72 179.3 137.2 112.6 96.9 86.2 78.9 74.6 74.0 70.8 84 112.1 85.4 69.6 59.4 52.3 47.2 44.1 43.6 40.9 96 74.8 } 56.7 46.1 39.1 34.2 30.7 28.4 28.0 26.0 108 52.339.6 32.1 27.1 23.6 22,1 19.4 19.1 17.7 DESIGN PRESSURE LIMITS FOR MULLION:22.5 Deg. -TWO-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 187.5 184.5 166.0 48 1 200.0 200.0 200.0 1 200.0 177.9 155.7 140.6 138.4 1245 60 200.0 200.0 181.3 151.1 129.5 113.3 102.4 100.7 90.6 72 174.8 131.1 104.9 87.4 74.9 65.6 59.2 58.3 52.5 84 110.1 82.6 66.1 55.1 47.2 41.3 37.3 36.7 33.0 96 1 73.8 55.3 44.3 36.9 31.6 27.7 1 25.0 24.6 22.1 i 108 51.8 1 38.9 31.1 2S.9 22.2 19.4 17.6 17.3 15.5 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant i Keystone Certifications,Inc. 145 Umekiln Rd,1008 New Cumberland,PA 17070 i Phone:717.932.8500 www.keystonecerts.com I ,I 11 1 Appendix 1 CAR No:622-104.0 it a..... .�� . _ .� Expiration Date:9/22/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 45 Degree Say/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:45 Deg. -ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.} (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 1 200.0 200.0 200.0 200.0 200.0 200.0 1 200.0 60 200.0 200.0 200.0 200.0 192.2 180.0 174.1 173.4 171.1 72 200.0 165.8 136.1 117.0 104.2 95.4 90.1 89.4 85.5 84 135.4 103.1 84.1 71.7 63.2 57.1 53.2 52.7 49.5 96 90.3 68.5 55.6 47.2 41.3 37.0 34.3 33.8 31.4 r 108 63.2 47.9 38.7 32.7 28.5 1 25.5 23.4 23.1 21.3 I DESIGN PRESSURE LIMITS FOR MULLION:45 Deg. -TWO-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 187.5 184.5 166.0 48 200.0 200.0 200.0 200.0 177.9 155.7 140.6 138.4 124.5 60 200.0 200.0 199.2 166.0 142.3 124.5 1125 110.7 99.6 72 200.0 158.4 126.7 105.6 90.5 79.2 71.6 70.4 63.4 84 133.0 99.8 79.8 66.5 57.0 49.9 45.1 44.3 39.9 96 89.1 66.8 53.5 44.6 38.2 33.4 30.2 29.7 26.7 d 108 62.6 46.9 37.6 31.3 Z6.8 23.5 21.2 20.9 18.8 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D i PA/TAS 201/203-Large Missile and Small Missile compliant If I I Keystone Certifications,Inc. 145 Limekiin Rd,100B New Cumberland,PA 17070 Phone:717.932.8500 j www.keystonecerts.com 1 i ' i Appendix 1 j CAR No:622-104.0 � �.r.. � •••.�*+� Expiration Date:9/22/2018 I Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 i Load Tables for the: 90 Degree Bay/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:90 Deg. -ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200. 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 199.2 72 200.0 200.0 200.0 184.5 167.4 155.7 148.6 147.6 142.3 84 200.0 183.3 149.5 127.5 112.3 101.5 94.6 93.6 87.9 96 160.5 121.8 98.9 1 83.9 73.4 65.8 60.9 60.2 55.9 108 112.4 85.1 68.9 58.2 50.7 45.2 1 41.6 1 41.1 37.9 i; DESIGN PRESSURE LIMITS FOR MULLION:90 Deg. -TWO-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 187.5 184.5 166.0 48 200.0 200.0 200.0 200.0 177.9 155.7 140.6 138.4 1245 60 200.0 200.0 199.2 166.0 142.3 124.5 112.5 110.7 99.6 j 72 200.0 200.0 166.0 138.4 118.6 103.8 93.8 92.2 83.0 i 84 200.0 177,3 141.9 118.2 101.3 88.7 80.1 78.8 70.9 96 158.4 118.8 95.0 79.2 67.9 59.4 53.7 52.8 47.5 E 108 111.2 1 83.4 66.7 55.6 1 47.7 41.7 37.7 37.1 33.4 i Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant a Keystone Certifications,Inc. 145 Limekiln Rd,10011 New Cumberland,PA 17070 Phone:717.932.8500 www.keystonecerts.com j i i BUILDING DROPS 398 East Dania Beach Blvd. Suite 338 Dania Beach,FL 33004 A Perfect Solution in Every Dropl 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com i Product Evaluation Report Of Eastern Architectural Systems HVHZ Clipped Aluminum Bay/Bow Mullions for Florida Product Approval FL# FL17472 Report No. 5504 6th Edition (2017) Florida Building Code Method: 1--A(Certification) Category: Windows Sub—Category: Mullions Product: HVHZ Clipped Aluminum Bay/Bow Mullions Material: Aluminum 6005-TS&6063-T6 Prepared for: Eastern Architectural Systems 16341 Domestic Ave. Ft Myers, FL 33912 .•� F. J•, Prepared by: �� Q,��,'.• i Hermes F. Norero, P.E. Florida Professional Engineer#73778 Date:02/06/18 T T Contents �''i •'•••••.••••• �� ��• Evaluation Report Pages 1—4NAL Digitally signed by Hermes F.Norero,P.E. Hermes10lo� Reason:I am approving this document Florida No.73?78 Date:2018.02.14 15:48:55-05'00' P - | F--� . ` \ � ` BUILDING ������0�N� ����NN���NN���� ������N-�� FL#: FL17472 Date: 02/06/18 1 APmvfect Solution in Every Dvopi Report No: 55O4 | certificat6vfAuthorization:zy57o Manufacturer: Eastern Architectural Systems Product Category: Windows i .� Product Sub-Category: Mullions Compliance Method: State Product Approval Method 1a i ' Product Name: HV`HZ Clipped Aluminum Bay/Bow Mullions | ] i Scope: This isaProduct Evaluation Report issued byHermes F.Norero,P'E(FL#73778)for Eastern � Architectural Systems based mn Method la of the State mfFlorida Product Approval,Florida . Department ofBusiness and Professional Regulation-Florida Building Commission. . Hermes F. Norero,P.E.does not have nor will acquire financial interest inthe company � manufacturing ordistributing the product ur|n any other entity involved in the approval process of| the product named herein. { This product has been evaluated for use in locations adhering to the 61h Edition(2017)Florida Building Code. See Installation Instructions PA-0004,signed and sealed byHermes F'Norem,P.E.(FL#73778)for specific use parameters. Limits mfUse: 1. Th|sproducthasbeenmva|uatedandisincompUanmewbhthe8mEdidon (2U17)F|ohda | Building Code,including the'High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall bebeyond wall dressing orstucco. | 3 When' i| Chapter 16ofthe 6mEdition(2D17) Florida Building Code and does not require an impact ' resistant covering.Individual window units must be impact rated where applicable. '| 4. Site conditions that deviate from the details ofdrawing PA-0004require further engineering analysis byalicensed engineer orregistered architect. S. All configurations shown in installation instructions PA-0004 have been qualified as required bySection 1709.8ofthe 611Edition(2017)F8C. . 6 �e�lnsta!fatfmn|n��uctions��,��04hz�si�eanddes|�npre�sureUm|tat|mns ' ' i ' l \ Hermes F. Norero, P'E. Florida No.73778 Page 3wf4 | : ! ! / K i u-__ ' i BUILDING DROPS FL*: FL17472 'S A Perfect Solution in Every Dropl Date: 02/06/18 Report Noo: 5504 Certificate of Authorization:29578 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through Keystone Certifications,Inc.(FBC Organization#:CER1523). Referenced Code Sections: 1. 1709.8 of the 6th Edition(2017)FBC I Referenced Data: 1. Product Testing performed by: Certified Testing Laboratories (FBC Organization#:TST1577) Report#:CTLA 3010W-4 Report Date:07/18/14 Report#:CTLA 3010W-4A Report Date:07/18/14 Report M CTLA 3010W-5 Report Date:07/18/14 Report#:CTLA 301OW-SA Report Date:07/18/14 Report M CTLA 301OW-6 Report Date:07/18/14 Report M CTLA 3010W-6A Report Date:07/18/14 Report#:CTLA 3010W-7 Report Date:07/18/14 Report#:CTLA 3010W-7A Report Date:07/18/14 Report#:CTLA 3010W-10 Report Date:09/22/14 Report#:CTLA 3010W-10A Report Date:09/22/14 TAS Reports Signed and Sealed by:Ramesh Patel,PE 20224 2. Certification Agency Keystone Certifications,Inc. (FBC Organization#:CER1523) ,1 I Hermes F.Norero, P.E. Florida No.73778 Page 3 of 4 I 1 • . t BUILDING DROPS FI_#: FL17472 i Solution In Eve Dro i Date: 0 o. 55 8 A Perfect Every p Report No: 5504 Certificate of Authorization:29578 installation: 1. Approved anchor types and substrates are as follows: A. For two by(2X)wood frame substrate,use#14 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50"into wood framing. f B. For concrete or masonry substrate where one by(1X),non-structural,wood bucking is employed,use 1/4"diameter ITW Tapcon type concrete screw anchors of sufficient I! length to achieve minimum embedment of 1.25"into concrete or masonry. E C. For concrete or masonry substrate where wood bucking is NOT employed,use 1/4" j diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For metal stud substrate,use 1/4"Grade 5 self-drilling screw type metal frame anchors of sufficient length to achieve a minimum three threads penetration beyond metal structure. Refer to Installation Instructions(PA-0004)for anchor locations,design load tables,and further details of the installation requirements. Design Pressure: See drawing PA-0004 for mullion desing pressure tables,mullion profiles,and installation details. l Hermes F.Norero,P.E. Florida No.73778 Page 4 of 4