Loading...
HomeMy WebLinkAboutProduct Approval 2/27/2019 Florida Building Code Online ® © 0 ® a p m 9 • 0 BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Mape I Links I BSearch a 5 Florid 1 Product Approval �y r � -- USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail • • FL# FL10124-R21 Application Type Revision Code Version 2017 Application Status Validated Comments Archived 1 Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .J Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By John W.Knezevich,PE 21 Validation Checklist-Hardcopy Received Certificate of Independence FL10124 R21 COI 2019 01 COI NIEMINEN.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 Equivalence of Product Standards Certified By https:/Ifloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3Bo0yLwXhMdCnnNOYyYYCg7Qp/o3d°/p3d 1/2 2/27/2a19 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/19/2019 Date Validated 02/19/2019 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R21 II 2019 02 FINAL ER GAF ASPHALT j Approved for use outside HVHZ:Yes SHINGLES FL10124-R21.Ddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10124 R21 AE 2019 02 FINAL ER GAF ASPHALT SHINGLES FL10124-R21.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Caoydyht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®® ® OEM Credit Card Safe i I https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCnnNOYyYYCg7Q%3d%3d 2/2 NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION GAF Evaluation Report 01506.01.08-1123 1 Campus Drive FL10124-R21 Parsippany,NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 23:02/18/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). MEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: ',`y^':F��i`• ":?4= The facsimile seal appearing was authorized by Robert Robert J.M.Nieminen,P.E. Florida Registration No.59166 Florida DCA ANE1983 ='r;;+,� ��`;� Nieminen,P.E.an d document This does not serve as an 9 , _� eledronicallysigneddocument. CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I I OMEMO I etc. ROOFING SYSTEMS EVALUATION: 1. O. Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Section ` .'Property Standard" Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Eritit 6(arninatlon " Refeierice Date PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) ASTM D1970(QuickStart) GAF-340-02-01 03/13/2012 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI(TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 NEMO ETC,LLC Evaluation Report 01506.01.08-1123 Certfcote ofAuthorizotion#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R21 GAF Asphalt Roof Shingles Revision 23:02/18/2019 Page 2 of 6 MEMO etc. Entit Examination Reference Date UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,133462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,133462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010 UL(TST 1740) ASTM D3462 1OCA07264 05/27/2010 UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018 UL,I.I.C.(TST 9628) ASTM D3161 4788891098 02/14/2019 UL,LLC.(QUA 9625) Quality Control Service Confirmation 10/18/2018 4. '••DDESCRIPTION: 41 . ACCESSORY STARTER STRIPS 4.1.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlock&I Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 QuickStart® Peel &Stick Starter Roll is a is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-inch or less. Meets ASTM D1970. 4.1.3 StarterMatchl Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon®and Grand Sequoia®series asphalt shingles. StarterMatchl are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. Meets ASTM D3462. 4.2.1 Marquis WeatherMax®,Royal Sovereign®and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles. 4.2.2 Camelot®, Camelot® II, Fortitudem, Glenwood'", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieldTM', Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldT' II, Timberline® Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles. 4.2.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. NEMO ETC,LLC Evaluation Report 01506.01.08-R23 Certificate of Authorizatlan#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1121 GAF Asphalt Roof Shingles Revision 23:02/18/2019 Page 3 of 6 i ONEMOletc. 4.3 HIP&RIDGE SHINGLES: 4.3.1 Seal-A-Ridge®Ridge Cap Shingles,Seal-A-Ridge®ArmorShield'"Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for i fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F.indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 61' GENERAL 6.1.1 Roof deck,slope,underlayment and fasteners shall comply with FBC 1507.2/R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. NEMO ETC,LLC Evaluation Report 01506.01.08-1123 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R21 GAF Asphalt Roof Shingles Revision 23:02/18/2019 Page 4 of 6 I OMEMO I etc. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. 6.4 HIP&RIDGE SHINGLES: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles 11.5° sealant and Seal-A-Ridge ArmorShield Ridge Cap (25 mm) (292 mm) (25. sellante Shingles shall comply with the GAF current Enduitdetancheite published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per t shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant". +r �• . 12, r (305 mm) Nail Clavo 6 518"-7 5/8" Clouer (168-194 mm) L _ 12° (305 mm)� j6.4.2 Installation of Timbertex Premium Ridge Cap 115° Shingles shall comply with GAF current published 1" (292 mm) vmm) Enduit Sealant g p y p 25 mmsellante instructions with a minimum two (2) nails, ( ) (25d'dtancheite minimum 3/8-inch head diameter, per shingleand beads of Sonneborn "NP1 Gun Grade A Polyurethane Sealant"or Henkel"PL Roofing and 11 Flashing Sealant". �) Nail Clavo 12" Clouer (305 mm) 9" (229 mm) 12" (305 mm) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. i MEMO ETC,LLC Evaluation Report 01506.01.08-1123 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R21 GAF Asphalt Roof Shingles Revision 23:02/18/2019 Page 5 of 6 ONEMO etc. 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. REQUIREMENTS:8. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 61G20-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- I NEMO ETC,LLC Evaluation Report 01506.01.08-R23 Certificate of Authorization#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R21 GAF Asphalt Roof Shingles Revision 23:02/18/2019 Page 6 of 6 I 6/.3/2018 Florida Building Code Online NIFTT No �Y BCIS Home Login I User Registration I Hot Topic Submit Surcharge Stats&Facts ( Publications MC Staff BCIS Site Map' Links I 'Search^ Florida 'rya _ t Product Approval USER:Public User ' 4�rizrex *� Product Approval Menu>Product or Application Search>Application List>Application Detail m r FL# FL2346-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ! i Product Manufacturer Warrior Roofing Manufacturing Address/Phone/Email 3050 Warrior Road Tuscaloosa,AL 35404 (205)553-1734 Ext115 Steven@WarriorRoofing.net Authorized Signature Steven Crew Steven@WarriorRooflng.net Technical Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa,AL 35404 (205)553-1734 Ext1024 Steven@WarriorRooflng.net Quality Assurance Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa,AL 35404 (205)553-1734 Ext1024 Steven@WarriorRoofing.net I Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 10/05/2021 Validated By Jesus Gonzalez, P.E. D Validation Checklist-Hardcopy Received Certificate of Independence FL2346 R7 COI PRI CMT Cert of Indeoendence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 ASTM D4869 2016 Equivalence of Product Standards Certified By Approved Testing Lab FL2346 R7 Equiv FBC 2017 Standards Equivalency pdf hfps://www.floridabuilding.org/pr/pr app_dU.aspx?param=wGEVXQwtDgtOc8bnSknRps9xp/o2fSloLpOST46ODBBp/o2baF4p/o3d 1/2 I 6/3/2018 Florida Building Code Online, r Product Approval Method Method 1 Option B r' Date Submitted 01/17/2018 Date Validated 01/17/2018 Date Pending FBC Approval 01/17/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or Name Description 2346.1 #15 and#30 roofing felt ASTM D 226 Tested Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2346 R7 II Instal latiohlnstructions.pddf, Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies,LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R7 TR ISA Test Report pdf Other:Primary roof covering should be installed immediately FL2346 R7 TR 30A Test Report.pdf after felt.Roofing felt is.not intended to be an unprotected weathering surface. 2346.2 15w and 30w roofing felt ASTM D 4869 Tested Limits of Use Installation Instructions Approved for use in HVHZ: No FL2346 R7 II InstallationInstructions.pdf Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies,LLC Impact Resistant:N/A Test Reports Design Pressure: N/A FL2346 R7 TR 15w Test Report.pdf Other:Primary roof covering should be installed immediately FL2346 R7 TR 30w Test Report.p_df after felt.Roofing felt is not intended to be an unprotected weathering surface. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.CC 'ght 2007-2013 State of Florida.::Privacy Statement::Accessibllity Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: Credit Card i ' Safe i https://www.floridabuilding.org/pr/pr app_ U.aspx?param=wGEVXQwtDgtOc8bnSknRpsgx%2fSloLpOST46ODBB%2baF4%3d 2/2 I - WARRIOR® ROOFING MANUFACTURING P.O.BOX 40185+TUSCALOOSA.AL 35404+PHONE(205)5534734*FAX(205)553-1755 193 LEROY ANDERSON ROAD+MONROE.GA 30655+PHONE(770)207-0695*FAX(770)207-0775 a 323 DEVELOPMENT AVENUE CHAMBERSBURG,PA 17201+PHONE(717)709-0323 FAX(717)7094)027 Roofing Felt Installation Recommendations Be aware that roofing felt should not be walked upon prior to fastening into position. Proper_safety equipment is recommended for all installations. Also,the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking,from edge to edge. Overhang is not required. Anchor the top corner of the felt after it has been properly positioned and roll the felt out across the roof. Pay careful attention to roll the felt out smoothly,avoiding wrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. The middle and bottom edge should also be fastened no less than every eight inches. Fasteners should be applied no less than every eight inches along the eaves. The next-course of felt should also be aligned with the roof edge and should overlap the previous course two inches(sometimes referred to as head lap). In the event you get to the end of a roll prior to getting to the opposite edge of the roof,begin a new roll with a four inch overlap over the end of the prior roll(sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course,fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the roof. Otherwise,overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys,lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley,be certain to start at the bottom and overlap:each_sull�sequent. length a minimum of two inches as you move up the valley I itQ r. ure p mate shedding. In the event some wrinkles are created while fastening down a course of felt,slice the i wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering(ex. Shingles)is recommended immediately after felt installation. NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. PW NO-