Loading...
HomeMy WebLinkAboutProduct Approval v I 8/16/2018 I Florida Building Code Online aw. BCIS Home Login User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us r BCIS sloe Map Unks ? Search b ? I ri' 91 Product Approval USER:Public User Product AP.proval Menu>Product or Aoolication Search>egolication list>Application Detail .FL# FL18355-114 1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer TAMKO Building Products,"Inc. Address/Phone/Email PO Box 1404_ Joplin,MO 64802 (417)624-6644 Ext 2305 kerrL-eden@tamko.com. Authorized Signature, Kerri Eden kerrl_eden@tamko.com Technical Representative Kerri Eden .Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerrl_eden@tamko.com Quality Assurance Representative i Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed'the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. A Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final.pdf Referenced Standard and Year(of Standard) Standard year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Eauiv UL letter for standards for FBC 2017.pdf https:/twww.floridabuilding.org/pr/pr apP dtl.aspx?param=.wGEVXQwtDquvosrHazGXQW83MPT3uofKzD1M2Xu9wuWmY6PQIJlukQ%3d%3d 112 8/16/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# (Model,Number or Name Description j 18355.1 Glass-Seal,Elite Glass-Seal, :ASTM D 3462 asphalt shingles and hip and ridge shingles j Heritage,Heritage Premium, Heritage Woodgate,Heritage I Vintage,Hip and Ridge,and Vintage Hip and Ridge Shingles, } �� Limits of Use Installation Instructions Approved for use in HVHZ:Yes i FI IS355 R4 II TBP15001 4 2017 FBC Eval Report ShingL- � Approved for use outside HVHZ:Yes Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A ; Created by Independent Third Party:Yes j Other:See evaluation report for limits of use. Evaluation Reports FI l8 55 R4 AE TBP15001 4 2017 FBC Eval RemShin_gLu final.pdf ( ( Created by Independent Third Party:Yes i— 0 Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The state of Florida Is an AA/EEo employer.eoovriaht 2007-2013 State of Florida.::Privacy statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/prlpr app_dU.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKzDlM2XugwuWmY6PQIJlukQa/o3d%3d 2/2 ' i r r Certificate of Authorization No.29824 -- 17520 Edinburgh Dr ` Tampa,FL 33647 TF—CHNOCAL SERVICES= ➢ LC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CooE,a EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS. issued September 25,2017 220 West4'"'Street Joplin,MO 64801 (417)624-6644 i Manufacturing Plants: Joplin,MO Phillipsburg,KS Frederick,MD Dallas,TX Tuscaloosa,.AL l Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles. Code Sections: 1504.1.1,-1507.2.5,1507.2.7.1,1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti Report No. t ndard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 'TAS 100 1995 PRl Construction Materials Technologies(TST5878) TAPA 402-01 TAS 100 1995 PRi Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131=02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 1oD 1995 .PRI Construction Materials Technologies(TST5878) TAP-007-02-01 TAS 100 1995. PRI Construction Materials Technologies(TST6878) TAP-314-02-01 Rev 2 'TAS 100 1995' ,PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 -PRI Construction Materials Technologies(TST5878) TAP 317-02-01 TAS 100 1995 UL LLC(TST9628) 0214K9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 -•2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 •.2008(2013)e1 UL 2390 i ASTM D 7158 2011 'UL LLC(TST9628) 06NK03898 ASTM D 3161' 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 10CA50498 ASTM D 3462 2010A UL LLC(TST9628) 10CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11 NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148746 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This'evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for,which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS I�4� ►fly Asphalt Shingles TECHNICAL SERVICES,LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-114"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36",ASTM D 7158,Class H self-sealing,3-tab asphalt shingle with fiberglass. (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shin-gles shall be used in the non-HVHZ only. Heritage@ 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class .H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage@ Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage@Premium 12"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Vintage@ 17-1/2"x 40",ASTM D 3161,Class F and ASTM D 7158,Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage@ Hip and Ridge 12"x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS fl`� Asphalt Shingles TECHNICAL.SERVICES,LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed,(Vuit): Max.194 mph (Frederick,Joplin,& Basic Wind Speed(Va,d): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;' & Solidly sheathed;min, 19/32 in. plywood or wood plank for Glass=seal new construction. Min: '15/32 'in. plywood existing (Frederick,Joplin(Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; i Solidly sheathed min, 15/32,in. plywood or wood'plank for new construction;Min.7/16 in.OSB existing construction. Undedayment: In accordance with FBC requirements. :Min.slope: , .2.12 and in accordance with FBC requirements. Refer to I the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattem" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAILS NaTng - - -......- _ __ _ J- 6-7Y9" Area Butt Et#ge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattem(Non-HVHZ only) NAILS • `fin .-_ 1": Nailing - — — --------- -- — — �:: ` — -- AM Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern I T80,15001,4 FL18355-R4 Page 3.of 11 This evaluation'ieport is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the.duration for which this report is valid. This evaluation report does not•express•nor•imply warranty,installation,recommended use-,.or other-product attributes that are not specifically addressed herein. �R�I TAMKOBUILDINGPRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed(V„it): Max.194 mph (Dallas,Frederick,Joplin, Basic Wind Speed(Vega): Max.150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas,Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): 'In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood "plank for Heritage@ Woodgate new construction;Min.7116 in.OSB existing construction. (Dallas&Frederick) Und6dayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENER$ NAIL ZONE COMMON BOND 6- 8" EOSU RE 6-618" 1" I - 12-1/2"-►� 12-318" -►'t- 12-1/9-`� �--1" Figure 3. Heritage@,Heritage@ Premium,and Heritage@ Woodgate(Dallas) 4 Nail Pattern(non-HVHZ only) FASTENERS4" NAIL ZONE COMMON BOND 610__ EXPOSURE 5-51W i�-►� h-7-1/2"-►�-7-1I2"-�T3r8"�-7-1/2°�-7 1/2"� h—i" Figure 4. Heritage@&Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration-for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS r=' CREEK l� Asphalt.Shingles TECHNICAL SERVICES,LLC ! NAIL ZONE/• ASTENERS COMMON BOND i F RE 5 5/8" 1° ' 112" 7,1/2 -3li3" 1I2 7-1l2 1 Figure 5. Heritage®Woodgate 6 Nail Pattern � - -►�i"�1"i�-12-10 =� Common Bond . FASTENERS E L I N � 1X. �W 39-3lB" i Figure 6. Heritage®,Heritage®Premium,&.Heritage.®Woodgate Alternate 6 Nail Pattern PAINT' LINE 7-7/8" — _ }NAIL ZONE EDGE OF 6-118" COMMON AL BOND EXPOSURE 5-5I8" . ACCEPTABLE FASTENER,LOCATION ! DO NOT FASTEN ALONG EDGE OF -COMMON BOND 'PREFERRED FASTENER LOCATION Figure 7. Heritage®(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4,and 6 may be placed in the nail zone as described above i .!TBP15001.4 FL16355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any producU changes or quality assurance changes throughout the duration for which this report is"valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. EjCREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,L.LC Heritage&Premium Basic Wind Speed(V,ir):. Max.194 mph (Frederick) Basic Wind Speed(Vase): Max 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7/16 in.0S13 existing construction. Undedayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12.. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published Installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND 5112" EXPOSURE 5" 1'�—+I �— 11"—►� 1211 lilt Figure Figure B. Herita9e@ Premium(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZONEI FASTENERS COMMON BOND 51/2" EXPOSURE 5" �-91/2!L- T 9"—+3-'I'-51/2° I*--711 Figure 9. Heritage&Premium(Frederick) 6 Nail Pattern TBP15001.4 FL18355•R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3_ The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. I `� TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC i Heritage®Woodgate Basic Wind Speed(V„t): Max.194 mph (Frederick) Basic Wind Speed(Vesd): Max.150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood.or wood plank for j new construction;Min.W16 in.OSB existing construction. j Underlayment: In accordance with FBC requirements. '.Min.slope:. 2:12 and in accordance with FBC requirements. Refer to 1 the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure In accordance with FBC I requirements and:.manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail I Pattern"or"ti Nail Pattern"detailed below. ,I NAIL ZONEI FASTE ME S COMMON BOND ;IqT } EXPOSURE V! -*.-..12-3I811 IV Figure 10. Heritageg Woodgate(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZON EI FASTENERS COMMON BOND iWEXPOSU RES" 1"� f 4-.9.1/2°�►�+3' 9�3/8°�►143' -9-1/2" �1-1° "Figure 11. Heritage®"Woodgate(Frederick) 6 Nail Pattern i TBP15001.4 FL18355-R4 Page 7 of 11 i This evaluation-report is provided for State of Florida product approval under Rule 6JG20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product"changes or quality assurance changes throughout the duration for which this report 1s valid. This evaluatiomreport does not express not imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS 1CREEK Asphalt Shingles TECHNicAL SERVICES,LLC Heritage@ Vintage@ Basic Wind Speed(Vwt): Max. 194 mph (Phillipsburg) Basic Wind Speed(Vega):• Max.150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattem" detailed below. Installation (Non-HVHZ): . Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail.Pattern"detailed below. Oar 5 ugmme � Fxposwe ��r z tbfzh b, Fayenes Ibn -- -- -- -- - - - one s° upw,re •v . Figure 12. Heritage@ Vintage@ 5 Nail Pattern(non-HVHZ only) .o• Notch +era Not a� s Figure 13. Heritage@ Vintage 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is,provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREElI Asphalt Shingles TECHNICAL SERVICES,LLC f Hip&Ridge Basic Wind Speed(V„it): Max.194 mph (Frederick&Joplin) Basic Wind Speed(Va,d): Max.150 mph Deck(HVHZ): In accordance with FBC requirements;. i Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; :Solidly sheathed min. 15/32 in.plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min,slope: 2:12 and in,accordance with-FBC requirements. Installation: Installed with 5-118 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed,end shall be away from the prevailing wind. ! Direction of prevailing wind Meart H5-1/8"exposure. rer ' hheret Figure 1 5-1/8"exposure SAS ` Fastener i F stener Figure 2 Figure 3 1/4 Figure 14. Hip&Ridge(Frederick 8 Joplin) i TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation-report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or-other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS 1 Asphalt Shingles ` TECHNICAL SERVICES, LLC Vintage®Hip&Ridge Basic Wind Speed(V„ir): Max.194 mph (Phillipsburg) Basic Wind Speed(Vasa): Max.150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Nbn-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: '2:12 and in accordance with FBC requirements. Installation: Installed with 5 Inch exposure In accordance with the FBC and manufacturer's published Installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind Start 51' exposure O l 11 Start here 5" exposure Figure 1 1" Fastener Fastener Figure 2 1 4 Figure S Figure 15. Vintage®Hip&Ridge(Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify,CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC LIMITATIONS i 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft In the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. I 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources,the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,-6th Edition(2017)as,evidenced in the referenced documents submitted by the named manufacturer. ,��IlurtUy 2017.09.25 No 74021 = 11 :31 :41 =-O- :jr- -04'00' 'p0:•. STATE OF :�� 0,� •.�� P,:���.` Zachary R.Priest,P.E. R:,. �% Florida Registration No.74021 Sift ON�q� ��' Organization No.ANE11669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC Is not owned,operated,or controlled by any company manufacturing or distributing products under i this evaluation. Zachary R.Priest;P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4_ Page 11 of 11 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein_