HomeMy WebLinkAboutFL Product Approval RHINO UNDERLAYMENT5/17/2019 Florida Building Code Online
8
-t 1+ sn�18 'aY5 �,"'rrfa F"h a 5 �6ir'ans
s
BCIS Home I. Log In ?, User Registration Hot Topics Submit Surcharge Stats & Facts ( Publications ` Contact Us 4 BCIS Site Map ( Links Search
db'. r
x USER:Product Approval
USER; Public User
Product Approval Menu > Product orApplication Search > Application List > Application Detail
FL #
FL15216-R4
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43645
(740) 321-6345
Greg.Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg.Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W. Knezevich, PE
" Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL15216 R4 COI 2018 01 COI NIEMINEN.pd
Standard
ASTM D1970 (tear)
ASTM D226 (physicals)
TAS 117(B)
Year
2015
2009
1995
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRAdhyl2u8kQGvTebw8xiQgg%2bDZLSjPcQRg%3d%3d 1/2
5/17/2019
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
FL #
15216.1
Florida Building Code Online
Model, Number or Name
RhinoRoof Underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See ER Section 5 for Limits of Use.
Method 1 Option D
04/20/2018
04/20/2018
04/22/2018
06/12/2018
04/19/2019
Description
Synthetic roof underlayments
Installation Instructions
FL15216 R4 II 2018 04 FINAL ER OWENS
CORNING RHINOROOF FL15216-R4.12df
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL15216 R4 AE 2018 04 FINAL ER OWENS
CORNING RHINOROOF FL15216-R4.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone 850-487-1824
The State of Florida is an AA/EEO employer. CQpyr19ht 2007-2013 State of Florida.:: Priva Statement :: Accessibility Statement :: Refund Statement
request, do not send electronic
Under Florida law, email addresses are public records. one ou do not want your e-mail address released in response to a t2ditionaI ma 1. if you have any questions, please contact 850.487.1395. 1s'Pursuan to Section 455.275(l),
mail to this entity. Instead, contact the office by p or bY they have one. The emails
Fproda Statutes
may be, effect
dive October
al 1, 2012, lice
ons es licen the I d under Chapter er 455,emaiF ddmust areprovpublic ecoid. If you do not wish to sup
ply fa personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® eG1�,cY
Credit
Safe
S'curity 111T1i17
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQWtDgv3yvVKJZl QRAdhyl2u8kQGvTebw8xiQgg°/a2bDZLSiPcQRg%3d%3d
2/2
MEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT LERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt, LLC Evaluation Report 140510.02.12-114
One Owens Corning Parkway FL15216-114
Toledo, OH 43659 Date of Issuance: 02/17/2012
(740) 321-6345 Revision 4: 04/19/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: RhinoRoof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
Robert J.M. Nieminen, P.E.
T
° , =,.
%��FS`1J
The facsimile seal appearing was authorized by Robert
`?;
�.
Nieminen, P.E. on This does not serve as an
Registration No. 59166, Florida DCA ANE1983
_-fir,,,,,,
Florida
d document.
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: RhinoRoof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, has
demonstrated compliance with the following sections of the 6t" Edition (2017) Florida Building Code through testing
in accordance with applicable sections of the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
Section
Properties
Standard
Year
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength, Pliability
ASTM D226
2009
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
TAS 110
Pull-through resistance
TAS 117(B)
1995
intitt
Examination
Reference
Date
ITS(TST1509)
Physical Properties
100539395COQ-006
10/27/2011
ITS(TST1509)
Physical Properties
100539395COQ-002
10/27/2011
ITS(TST1509)
Physical Properties
100539395COQ-006
03/14/2014
PRI (TST5878)
ASTM D1970; Tear strength
DCF -330-02-02
10/03/2017
PRI (TST5878)
TAS 117(8); Pull-through
OCF-422-02-01
04/03/2018
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42 -inch wide rolls,
and can be produced in various other sizes; meets FBC 1507.1.1 & R905.1.1 (Exception).
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5
Allowable Roof Covers:
5.6 Exposure Limitations:
RhinoRoof U20 shall not be left exposed for longer than 30 -days after installation.
NEMO ETC, LLC Evaluation Report 140510.02.12-114
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL15216-114
RhinoRoof Underlayments Revision 4:04/19/2018
Page 2 of 4
ONEMOletc.
6.1 RhinoRoof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 RhinoRoof U20•
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment In FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width.
6.3.2 Fasteners:
For exposure < 24 hours, corrosion resistant fasteners may be 1 -inch roofing nails with a 3/8 -inch diameter head,
minimum 1 -inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough
edge facing up). The use of staples is prohibited.
For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1 -inch diameter
plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use
of staples is prohibited.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: ':..except metal cap nails
shall be required where the ultimate design wind speed, V„Ir, equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1 -inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the RhinoRoof U20 underlayment is installed beneath
mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1.
6.3.3 Single Laver• Roof Slope > 4:12:
End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. Refer to
Owens Corning Roofing and Asphalt, LLC recommendations for alternate lap configurations and/or the use of
sealant under certain conditions.
For exposure < 24 hours, use of every -other fastening location printed on the surface is acceptable. For exposure
> 24 hours up to maximum 30 -days, use of every fastening location printed on the surface is required.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If
this occurs, remove the cap nail and patch the hole in accordance with Owens Corning Roofing and Asphalt, LLC
published instructions.
6.3.4 Double Laver; 2:12 < Roof Slope < 4:12:
End (vertical) laps shall be minimum 12 -inches and side (horizontal) laps shall be minimum half -sheet -width plus
1 -inch.
Double layer application; begin by fastening a half -width plus 1 -inch starter strip along the eaves. Place a full -
width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but
maintaining minimum half -width plus 1 -inch side (horizontal) laps, resulting in a double -layer application.
Evaluation Report 140510.02.12-114
NEMO ETC, LLC F1.15216-114
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
RhinoRoof Underlayments Revision 4: 04/1e 3 of 4
Page 3 of 4
ONEMO I etc.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Qingdao, China
Intertek Testing Services NA Inc. — QUA1673; (608) 836-4400
- END OF EVALUATION REPORT -
Evaluation Report 140510.02.12-114
NEMO ETC, LLC FL15216-R4
Certificate of Authorization #32455 br" EDITION hinoR FBC NONlayme-HVHZ EVALUATION Revision 4:04/19/2018
RhinoRoof Underlayments
Page 4 of 4