HomeMy WebLinkAboutProduct ApprovalanOY cJ �� eries INSTALLATION AND OPERATION MANUAL Jandy Pro Series JXi TM Gas -Fired Pool and Spa Heater Models 200, 260, 400 FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists: the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Immediately switch off main gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Page 8 Jandy16 Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual Section 3. Location Requirements The JXi heater is shipped from the factory- with an exhaust vent configured for outdoor installation. The heater is also design -certified for indoor installations in the United States and for outdoor shelter installations in Canada. See Stciion 3.3 for details. Location of the heater below or above the pool water level affects operation of its water pressure switch. See sections i.3 for more information. 3.1 Clearances The heater must be installed in a location that allows clearances for maintenance and inspection. Minimum distances from combustible surfaces must also be maintained. All criteria given in the following Sections reflect minimum clearances as stated in the national standards. However, each installation must also be evaluated, taking into account prevailing local conditions such as wind speed and direction, proximity and height of obstructions that may block ventilation. and proximity to public access areas. Combustible Surface 6 in (15 cm) Service Clearance TOP: 36 in (45 cm) FRONT: 18 in (22.5 cm) USA 24 in (30 cm) Canada required per CSA B149.1, section 4.14.2. NOTE: Clearances are manufacturer's tested values. These are given as minimum values. Where local and national codes apply, and if the clearance values specified in the applicable codes are different than those listed in this manual, use the greater value to ensure safest operation. Figure 2. Clearances F OTE: If the heater is to be operated in below freezing conditions it ould be installed in a protected outdoor shelter. CAUTION When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or flooding. Zodiac Pool Systems, Inc., cannot be responsible for such water loss or flooding or resulting damage. Service Clearance: 36 inches (45 cm) from top of heater for removal of top panel. 18 inches in the us and'_4 inches Q0 cm) in Canada from one of either the front or rear panels. Combustible Surfaces: Each heater face requires a 6 inch 05 cm) clearance from combustible surfaces. Although it is not advisable, the heater base can be placed on a combustible surface for operation. However, do not install the heater on carpet. O Page 10 Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual 3.2.1 Anchor Bracket Installation Anchor brackets do not come standard with the JXi if you require the anchor brackets for your installation please order kit #RO593400. Anchor brackets should be installed in any circumstance where the heater may be subject to natural risks such as extreme weather or earthquake. In Florida, the heater is required to be securely fastened to the equipment pad to meet the applicable requirements of the Florida Building Code. Other jurisdictions may have similar requirements for extreme weather or other natural hazards. Check your local codes for details. 0 Using an adjustable wrench or equivalent tool loosen (DO NOT REMOVE) the retaining nut on the bracket. The upper and lower anchor bracket should be able to rotate freely about the retaining pin. 0 Slide the bracket into the slot located at the lower comer of the heater base. QRotate lower anchor bracket into final position. Ensure that the lower anchor bracket is flush with the equipment pad surface and level. Anchor Bracket Upper Retaining Nut — Retaining Pin Anchor Bracket Lower Concrete Equipment Pad — `—' JAU Heater Base — Anchor Bracket Slot `— Concrete Screw ANCHOR BRACKET INSTALLATION SECTION VIEW QTighten the retaining nut so that the anchor bracket assembly is secure. 0 Drill a hole in the concrete using the lower anchor bracket hole as a guide. It is advised that a hammer drill with an appropriate concrete drill bit be used. OPlace a screw in the hole and tighten to fasten the anchor bracket to the concrete pad. Do not over torque the screws. NOTE: Depending on the location of and access to the bracket, it may be necessary to mark the drill location using the lower anchor bracket hole as a guide. Remove the bracket from the heater, drill the hole and then reattach the bracket to the heater base. NOTE: Concrete screws are not provided in the anchor bracket kit. Use size 1/4" x 2-1/4" galvanized or plated concrete screws and washers. Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 9 3.2 Outdoor Installation Locate the heater: • On a level Solid Surface • 5 ft (1.5 m) from inner pool edge unless separated by a permanent solid barrier, i.e. a wall or fence • In an open area, not under a deck or other structure • Away from doors windows or louvers that connect in any way to occupied or inhabited areas of the building. NOTE: In Canada the top of the exhaust vent must beat least 10 feet (3 m) from any building opening.. • Away from rainwater runoff • Away from potential sprinkler water intrusion • So that the top of the heater is at least 3 feet (1 m) below any overhang • So that the top surface of the heater is at least 3 feet (I m) above any forced air inlet within 10 feet (3 m) If the heater is installed close to a structure, protect it from rain water runoff with rain gutters on the roof or other measures. The area under an Be sure to divert rain water runoff away from heater overhang must be open on three sides to In the United States install the heater so that there is at least a prevent combustion three (3) foot (1 m) clearance between the bottom of the gases from being overhang to the top of the heater exhaust vent. diverted into living areas through doors, Do not install the heater with the top of the vent assembly within windows, or gravity 4 feet (1.22 m) horizontally, 4 feet (1.22 m) below or less than 1 ft inlets (300 mm) above of any opening into a building. Local codes and installation requirements may vary. In Canada, install the heater so that the top of the vent is at least 10 feet (3.0 m) from any building opening. The top of the heater exhaust vent must be at least 3 feet (1 m) above any forced air inlet, or intake ducts located within 10 feet (3.0 m) horizontally Do not locate the heater below or adjacent to any Locate the heater on a level surface in an open, unroofed area. doors, windows, louvers, Do not install the heater under a deck. grills, etc., which connect in any way with an ® ; inhabited area of a building, even though the access might be through Imo-- min. 5 ft (1.5 m) another structure (e.g., a g unless the heater is garage or utility room). I separated from the pool by a solid fence, wall or other permanent solid barrier. Do not locate the heater near sprinkler The heater must be installed on a level, solid, and firm surface or platform. systems that could spray water on it. Although it is always advisable to install the heater on a non-combustible Water from sprinklers can damage surface, the JXi-series has been CSA-certified for installation on solid, controls and electronic components. I firm, and level combustible surfaces. DO NOT INSTALL ON CARPET. Figure 3. Location Requirements A WARNING United States Do not install the heater with the top of the vent assembly within 4 feet (1.22 m) horizontally, 4 feet (1.22 m) below or less than 1 ft (300 mm) above of any opening into a building. Local codes and installation requirements may vary. Canada Do not install the heater with the top of the vent assembly within 10 feet (3.0 m) of any opening into a building. Local codes and installation requirements may vary. Page 8 Jandv" Pro Series, A' Gas -Fired Pool & Spa Heater Installation & Operation Manual Section 3. Location Requirements The JXi heater is shipped from the factory with an exhaust vent configured for outdoor installation. The heater is also design -certified for indoor installations in the United States and for outdoor shelter installations in Canada. See Section 3.3 for details. Location of the heater below or above the pool water level affects operation of its water pressure switch. See sections 5.3 for more information. 3.1 Clearances The heater must be installed in a location that allows clearances for maintenance and inspection. Minimum distances from combustible surfaces must also be maintained. All criteria given in the following sections reflect minimum clearances as stated in the national standards. However, each installation must also be evaluated, taking into account prevailing local conditions such as wind speed and direction, proximity and height of obstructions that may block ventilation, and proximity to public access areas. ✓> Combustible ((1 Surface 6in(15cm) Service Clearance TOP: 36 in (45 cm) FRONT:18 in (22.5 cm) USA 24 in (30 cm) Canada required per CSA B149.1, section 4.14.2. NOTE: Clearances are manufacturer's tested values. These are given as minimum values. Where local and national codes apply, and if the clearance values specified in the applicable codes are different than those listed in this manual, use the greater value to ensure safest operation. Figure 2. Clearances NOTE: If the heater is to be operated in below freezing conditions it should be installed in a protected outdoor shelter. CAUTION When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or flooding. Zodiac Pool Systems, Inc., cannot be responsible for such water loss or flooding or resulting damage. Service Clearance: 36 inches (45 cm) from top of heater for removal of top panel. 18 inches in the us and 24 inches (30 cm) in Canada from one of either the front or rear panels. Combustible Surfaces: Each heater face requires a 6 inch (15 cm) clearance from combustible surfaces. Although it is not advisable, the heater base can be placed on a combustible surface for operation. However, do not install the heater on carpet. Page 4 UNIN Jandy" Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual 1.5 Specifications INSTALLATION LOCATION' SUPPLY GAS NATURAL GAS NG CERTIFIED INDOOR/OUTDOOR LIQUID PROPANE (LP) CERTIFIED INDOOR (US ONLY) I OUTDOOR I COVERED SHELTER GAS PIPE HEATER GAS VALVE CONNECTIONt NATURAL GAS (NG) 3/4" NPT LIQUID PROPANE (LP) 3/4" NPT INLET GAS SUPPLY PRESSURE Min NATURAL GAS (NG) 4.0" WC LIQUID PROPANE (LP) Max 10.0" WC 14.0" WC GAS VALVE OFFSET PRESSURE# NATURAL GAS (NG) 2 WC 2" WC LIQUID PROPANE (LP) WATER PIPE/HEATER CONNECTION NATURAL GAS (NG) PVC/CPVC 2" unthreaded Jandy Pro Series threaded union LIQUID PROPANE (LP) WATER FLOW RATE Min Max NATURAL GAS (NG) 30 gpm (76 Ipm) 100 gpm (454 Ipm) LIQUID PROPANE (LP) WORKING WATER PRESSURE Min Max NATURAL GAS (NG) 2 psi 50 psi LIQUID PROPANE (LP) EXHAUST VENT CONNECTION SIZE (CATEGORY 09 NATURAL GAS (NG) Model 200: 6 " Model 260: 7 " Model 400: 8 " LIQUID PROPANE (LP) EXHAUST VENT CONNECTION SIZE (CATEGORY III) NATURAL GAS (NG) See Section 3.3.3 LIQUID PROPANE (LP) ELECTRICAL SUPPLY NATURAL GAS (NG) 120 VAC 240 VAC LIQUID PROPANE (LP) HIGH ALTITUDE NATURAL GAS (NG) Appliances are normally derated when installed at high elevation. This is not necessary with the JXi heater because it has a special ventud-type combustion system which self -compensates for changes in barometric pressure. Air flow through the blower inlet pulls the correct flow of gas into the burner regardless of air density. JXi heaters are CSA certified for elevations of up to 4,500 feet above sea level. At elevations above 4,500 ft., the heater BTU output can be expected to be reduced by 4% for every 1,000 feet over 4,500 feet above sea level. LIQUID PROPANE (LP) * Indoor installation is not recommended for liquid propane heaters. Review Special Precautions for liquid propane heaters (Section 4.4) Any changes to the heater, gas controls, air orifice, gas orifices, wiring, or tFor gas pipe size requirements see Section 4 improper installation may void the warranty. If change is required to any of the above; contact your local Jandy distributor, visit www.jandy.com or call $ All readings must be taken while the heater is operating technical support at 800.822.7933. § Use type B double -wall gas vent, per table 13.1(a) NFPA 54 1.6 Dimensions 26.5" (67 cm) 24.9" (63 cm) 16" (40.6 cm) Dimensions are idendcai for all heater models • I•f C$®T `I auuo O 22.1" (56 cm) �I 5.1" (13 cm) h f 21.6" (55 cm) 35.4" (90 cm) Versa PlumbOinlet Inlet c (47cm 10.13" 5.6" (26 cm) (14 cm) Figure 1. General Dimensions Page 10 NEWJandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manual 3.2.1 Anchor Bracket Installation Anchor brackets do not come standard with the JXi if you require the anchor brackets for your installation please order kit #R0593400. Anchor brackets should be installed in any circumstance where the heater may be subject to natural risks such as extreme weather or earthquake. In Florida, the heater is required to be securely fastened to the equipment pad to meet the applicable requirements of the Florida Building Code. Other jurisdictions may have similar requirements for extreme weather or other natural hazards. Check your local codes for details. 0 Using an adjustable wrench or equivalent tool loosen (DO NOT REMOVE) the retaining nut on the bracket. The upper and lower anchor bracket should be able to rotate freely about the retaining pin. 0 Slide the bracket into the slot located at the lower corner of the heater base. ORotate lower anchor bracket into final position. Ensure that the lower anchor bracket is flush with the equipment pad surface and level. Anchor Bracket Upl Retaining Nut Retaining Anchor Bracket Lower Concrete Equipment Pad ---, JXi' Heater Base — Anchor Bracket Slot ' — Concrete Screw ANCHOR BRACKET INSTALLATION SECTION VIEW ❑q QTighten the retaining nut so that the anchor bracket assembly is secure. QDrill a hole in the concrete using the lower anchor bracket hole as a guide. It is advised that a hammer drill with an appropriate concrete drill bit be used. © Place a screw in the hole and tighten to fasten the anchor bracket to the concrete pad. Do not over torque the screws. NOTE: Depending on the location of and access to the bracket, it may be necessary to mark the drill location using the lower anchor bracket hole as a guide. Remove the bracket from the heater, drill the hole and then reattach the bracket to the heater base. NOTE: Concrete screws are not provided in the anchor bracket kit. Use size 1/4" x 2-1/4" galvanized or plated concrete screws and washers.