Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
Florida Building Code Online Page 1 of 3 SRI i�„y fi'v L tit Ti'1. �la .irt I5io lT s'r LFav� a' r v, Ift'. _...r� BaS Home Log In -`user Registration Hot Topics,l Submit Surcharge i Stats&Facts publications I FBC Stan f SCIS Site Ma i•Un. ` 7011.^8 amixn, Product Approval USER:Public User JUL 2 L 2019 r Produrt Aoma••al Menu>Rrorluct or AnMttation Search>Anollcation List>Appllcatlen Detail ST. Lucie County, Permitting FLFL17022-R7 —_- Revision _ Code Version 2017 _ __.._.__. APPIIcation,S,tatus_.. Approved...._. __.._.._..._ Comments 08/18/2017v.date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 ---- --- -- (772)-872=803 — --- flvalidation@yahoo.com Authorized Signature Richard on@yaMcKuhen REVIEWED FOR Flvalldation@yahoo.com REVIEWED /�g��J /�w, Technical Representative Richard McKuhen CODE COMPLIANCE NCE Address/Phone/Email 2160 SW PFL 3 Drive T. L U C I E C O U b©W Palm City,FL 34990 (772)872-8034 rlchard@emfab.net B O C C Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Elorlda_License ----------.-PE-48704 - Quality Assurance Entity Keystone Certifications,Inc. ..-_Quality.AssuranceContract-Expiration Date _-.__..._.._-04/22/2024- Validated By Zachary R.Priest,P.E. El Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.OdF Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 1.x..,.-./L------�----��t--_•t-t• - - r r ,., n .-..-.tea..-. ..-. .. .-... __ ... .. _ .. -•- - - - Florida Building Code Online Page 2 of 3 r s Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL 9 Model,Number or Name Description 17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32'plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 SV CRIMP ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Cher:-Referto-eVaivation-report-for-conditkrns-lnstalhth FL-1-7c^22 R '_�C-RIMP--ssrod assembly In compliance with the installation method listed In this Created by Independent Third Party:Yes report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel, mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FLI7022 R7 I1 FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No I Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for condltlons.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf assembly In compliance with the Installation method listed In this Created by Independent Third Party:Yes report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.3 3-"1.5"Mechanical Seam"(R5) 1.5"rib height,16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 24aa ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 17022 3 1 5 MECHANICAL seam 24aa ssr.odf use.Install the assembly in compliance with the installation method Created by Independent Third Party:Yes listed In this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr.odf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other_:_RefeT-to_evaluation_report_[or_condltions a.Rd imttatlon of Evaluation_�eports use.Install the assembly In compliance with the installation method FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM listed In this report and applicable code sections of FBC.Refer to ALUMINUM ssr.odf -manufacturer's Installation Instalctions. d hy Tndel)endentrd Party:Yes 17022.5 5-"1 in.Nail Strip"(RS) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSfRIP ssr.odf Approved for use outside HVHZ:Yes Verined By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf use.Install the assembly In compliance with the installation method Created by Independent Third Party:Yes listed In this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.6 6-"1 In.Nall Strip"(115) 1"rib height,16"wide,0.032'aluminum,standing seam roof panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluatlon report for conditions and limitations of FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0,032 ALUM ssr.odf use.Install the assembly In compliance with the installation method Created by Independent Third Party:Yes listed In this report and applicable code sections of FBC.Refer to manufacturer's installation Instructions. 17022.7 7-"1.5 In.Nail Strip"(115) Florida Building Code Online Page 3 of 3 11.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 17 FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.Ddf use.Install the assembly In compliance with the Installation method Created by Independent Third Party:Yes listed In this report and applicable code sections or FBC.Refer to manufacturer's Installation Instructions, mechanically attacned to plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf use.Install the assembly In compliance with the Installation method Created by Independent Third Party:Yes listed in this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.9 9-a PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations of FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf use.Install the assembly In compliance with the Installation method Created by Independent Third Party:Yes listed In this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions, .Back Next Contactus::2601 alalr Stane Road.Tallahassee R 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO emplayer.Copyright 2007-2013 State of Florida.::Pnvow statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your&mail address released In response to a public-records request,do not send electronic mall to this entity. Instead,contact the office by phone or by Vaditlonal mall.Ifyou have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address It they have one.The malls provided may be used far offidal communication with the licensee.However email addresses are public record.If you do not wish to mpply a personal address,please provide the Department with an email address which can be made available to the public To determine If you,am a licensee under Chapter 455,F.S.,please dick her., Product Approval Accepts: Gfe'dit:'Ceard I 2160 SW A"'i Drive Palm City, FL 34990 . . . . .. •--- 7�72)•87� .8034 • r ' • a + . e o 0 - • ui3•' G . t: Compliant with Florida Product Approval Rule#6,1G20-3, �.- Compliant: Keystone Certifications -.*Product: 5 V Crimp 26GA Steel Roof Panel FBC-Sec: 1507 4:2''.:.:_; Yield strength: 50 ksi min.; Attached to min '15/32"plywood;or.:Vilo6d. Deck w►/min..0.42 specific gravity with screws 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant:-FBC Sec. 150,7-..4 3... "Fastener 1"(Method 1 Attachment):#9 x 1-1/2" Hex=1Alastier Flead wiiod screw*to:penetrate 3/16" min:.thru:deck or 5/8"embedment into wood plank (*or sufficient IengtF�`to meet requirernents) Fastener 2(Method 2,3, &4 Attachment):#10 x 1 1/2" Heb Washer Mead tioodscrew -.to penetrate 3/16" min. thru.deck or 5/8" embedment int®wiood -1- iik. (nor s.ufficient'length to•meet requirements) Underlayment: To be compliant with FBC Sec. Cherft 1507:1.1 Slope: Shall,be in-compliance with FBC Sec. 1. = See fastener aft, hment specifications-a D'o' ve Install Deta�is:Table�4 :-.,AI.Iowble-loads IIIIETHOp 1.._ METHOD,2_ METHOD 3. METHOD 4 ;DESIGN.PRESSURE*_.'. '. . 86 PSF 93.;5 PSS.;-- L101 PSF 228 PSF.:_ AROW_SPQiCING 16,E o c _,_ �.1fi"o �.._...... . :`8►,o c 6";�c: : pSTE1dER SPACING_(ALONG Panel_width). :.. 12" .1t STIZE Reference Data ARCHITECTURALTESTING,'INC10." , 4'0',1527 t1L 580 06 i997;041YTest Report 1893 01 46,0-18 05/02/34 .. Test Report :F3366 01,450-18 12/18/15 ' TAS 125-03 Test Report DQ5893.02 450'_18 07/22/14 *EQUNALENCY=l1L Y897a04,is equivalent_to teststandard UL 1897 I *Design pressure margin ofsafety 2 3 — - 2 f 11►FI►r�. locke PgWden P.E does not have,not will ac uire a financial 1rt ��__����i` s c 1 H factunn or dlstnbutin roducts under thM. is evaluation �' Locke Bowden,P.E is not owned operated,or controlled by algy:co6npalilrDlnb$'afaZaure%or distributing`producFs unde_r.this report tl • •$ TLS_ • 4! (� — 0 , r . �.�:=t<<, ►tai►►�.� . . FL17022A 5V Crimpy (26GA Steel), 24" Wide Roof panel - Details Limitations: 1. Underlayrnent to be compliance with current Florida Building Code(FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. astene • - n.Or _ _..... .............__. _... _ ...... ._....... ., .... ....._. -. . _.. #10%7_Ir Min,.perTablaA"forl2ow...._/77777.SVCrimpR...oofPanel._............. ..__.......Spacing and Design Pressures Hex Washer Head Wood Screws r,- r i ,av, O „'• ti �QZ L A - j:a• Deck: 15132'or greater Plywood,or Mod plank 24- 1i" 318" o i I —............ — Panel Profile Nominal 12" Nominal 12" O.C. D.C. Fasten 9_x1-1/2"Min. or #10 X 1-1/2"Min.per -fable"A" Hex Masher Head Screw . Spaced 12"o.c.across the Panel VWth Panel Refer to Table"A"for Spacing Along Panel Overlap Length Deck-15/32"or greater Plywood,or -V1bod plank