Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (3)
Florida Building Code Online Page I of 2 9 8CIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us SCIS Site Map Unks a o r @USER:Product Approval P�oval RECEIVED JUL 2 2 2019 Product hhnroval Menu>Product or AnolicaUnn Search>h�hcation Litil>Application Detail FL, FL2418-Ril ST. Lucie County, Permitting Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and rat by the POC and/or the Commission if necessary. Comments RE-`9flIES0 FOR Archived CODE COMPLIANCE Product Manufacturer Maxim Industries,IrS"r. LUCIE COUNT'S' Address/Phone/Email 1630 Terre Colony Court Dallas,TX 75212-6221 B®CC (214)905-2021 Info@maximskylights.com Authorized Signature David Thornton info@maximskylights.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL2418 R1l L"auiv EER2000 Rev2 418-0102 MAX0001- DSF MAX0002-DCM SS.odf littps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsI UBZYvQ3... 10/22/2018 Florida Building Code Online Page 2 of 2 r Product Approval Method Method 1 Option A Date Submitted 03/05/2018 Date Validated 03/06/2018 Date Pending FBC Approval Date Approved 03/09/2018 Summary of Products FL# Model,Number or Name Description 2418.1 Series"DCM"Dade Curb Mount Polycarbonate Glazed Aluminum Skylight Skylight Umits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL2418 1111 C CAC N1009198.01-115 DCM.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Reslstant:Yes 12/31/2021 Design Pressure:+60/-60 Installation Instructions Other: FL2418 R11 II MAX0002 RevB DCM ss.Ddf Verified By:'Robert J.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL2418 R11 AE PER2000 Rev2 418-0102 MAX0001- DSF MAX0002-DCM SS.edf Created by Independent Third Party:Yes 2418.2 Series"DSF"Dade Self Flashing Polycarbonate Glazed Aluminum Skylight Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL2418 R11 C CAC N1009198-RS DSF.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2021 Design Pressure:+60/-60 Installation Instructions Other: FL2418 R11 11 MAX0001 RevC DSF ss.odf Verified By: Robert 3.Amoruso,PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL2418 R31 AE PER2000 Rev2 418-0102 MAX0001- DSF MAX0002-DCM ss.Ddf Created by Independent Third Party:Yes Back Na:t Contact Us::2601 SlalrStone Road.Tallahassee Fr 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statemen Under Florlda law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send el mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-pursuant to Section (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have c emal:s provided may be used for ofrlcial communication with the licensee.however email addresses are public record.If you do not wish to supply a personal please provide the Department with an email address which an be made available to the public To determine if you art:a licensee under Chapter 455,F.S., dick h=. Product Approval Accepts: LFRM®®EE Credit Card Safe https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgslUBZYvQ3... 10/22/2018 g g MAXIM INDUSTRIES, INC. SERIES "DCM" DADE CURB MOUNT SKYLIGHT INSTALLATION ANCHORAGE DETAILS o a p GENFRAL Renes: INSTALLATION NOTES: WMA:(.FROM..( 10.50'MAX 1.THIS PRODUCT IS DESIGNED TO COMPLY WITH THE HIGH CORNERS TYP. 1 I I O.C.TYP. I.ONCKO LOATIONS ANCHOR REQUIRED AT EACH EVELOCITY DMNCFDMCANEZONE(11V11A OF CODII(FBCRTHE ANCIMORLOG710N SHOWN. PRODUCT DETAILS CONTAINED ERGINE ARE i T 1 1 T e o PRODUCT DETAILS fAMAWEO HEREIN ANE BASED UPON 1THE NUMBf01 OF INSTALLATION ANCHORS DEPICTED ARE � p SGNEDANDSEALEDTESTREPORTAT10143381A11WD THE MINIMUM NUMBER OF ANCHORS TO DE USED FOR 4'MAX FROM r~ all ASSOCIATED LABORATORY DRAWING& PRODUCTINSTAtLAT1ON. ~ O S LADEQUACYOF THE EXISTING STRUCTURAL FRAMWOASA T.FOR INSTALLATION INTOWOOD ROOF DECILUSE DI] CORNERS I I O S MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WOOD SCREWS OF SUFFICIENT LENGTH TOACHIEVE 1016 S a WrrMSTANOL4GANOTRANSFEFUW40MPUEDPROOUCT INCH MBIDNUMEMBEOMENTAM MUMEDOEDISTAHCEIS I I Npu� x < O ENGINMORARCNRECT CORD, NS®LLLTYOFIHE IMM SINARFASWNERE WWD80RNE DEBRIS PROTECTION 4.MRdlAI1 TIMEOMENTAND EDGE DISTANCE DTCWDE I I 'p az a REQUIREMENTS EXIST USE OFANAPPROVED IMPACT SUCCO.FDFS.D10.UDENINQ BUTNOTIDRIEDTO W IRO S 3111000,WAN,BR1CI(VENEERAND SWIiO. PROTECTIVE SYSTEM ISNOTREOUIMED. 1050'MAX 0.DWAUATIONANCHORSSIUILLBE[WALLEOW O.C.TYP. I I ~ 9� g I! . $ MAX 100t' o 1 4.1.SKYLIGHT ACCOADANCEWITH ANCHOR MANUFACTURERS OA MAX 4.1.BKYUGM FRAME6060-TBEIGRUDEDALUMINUM. INSTALLATION 0ISTRUCDONS ANDAINCIORS SWILL ""' I I FAD OA 0 4.L SNYUSNT DINERANOOUTERIIOMEMATERMU: NOTBEUSEDINSZIBSTRATESWRNSTRFRGTMLM CURB DA !!{ NAIMCRON POLYCARBONATE BYCOVESTRO.LLC PER TWNIwemINDNA/STRENGTH SPECIFIED BYTHE I I .--. O.L.O. LENCTH LENGTH CURRENT MAMFOADE NMA COMPONENT APPROVAL ANCHORMANUFACTURER. LENGTH B.INSTALLAmON ANCHOR CAPACTRES FORPRODUCTSHEREIN ARE v�V ANOP ON NOPERTIEE& NATER WSWRN THEFOLLOO A.WDOO-MINIMUM SPECIFIC GRAVITY OF DAL L — i 1 1 1 1 1 I 48'AUL%.OA FU(EO D.L.O.WIDTH Rm�1LAnwr,Pd P.L ft Grit 51t MAX OA CURB WIDTH Digitally 5z} signed by 5216&MAT.OA 02018.03.05 Robert J wroTH TABLE MF CONTENTSAfnOTL50 SHEET REV. SHEETDESCRIPRON DEEIGNPRESSDRERATING(PSn WAMTRATING ELEVATION&ANCHOR Date: NOTMELEVATWNSAIMORLAYUUT LARGEAVSS6E LAYOUT x — sECTIONVIEWS tEOD IMPACT 10:08:11 EXTERIOR VIEW -01 low l 1. Minimum#12 fastener by others.Pre-punched Installation holes 4'from each comer,maximum 10.5"on center.Minimum penetration=1-318". 2. .060"X 1.5"X 1.75'6063-T6 extruded aluminum retaining angle.Aluminum angle mitered and welded @ four comers. s a A° a 3. 52.5"X 100.375"W Enhanced outer Makrolon Polycarbonate Dome by Covestro,LLC @ 8"height on test sample dome height varies per skylight size but not S m less than the larger of 10%of the dome's span or 4) LL 4. 52.6"X 100.375"UV Enhanced Inner Makrolon Polycarbonate Dome by Covestro,LLC @ 4"height on lest sample (dome height varies per skylight size but R not less than the larger of 10%of the dome's span or 41 . o t v C 9 8 S. OSI PR256 urethane sealant Located between aluminum retaining angle and outer dome&between Inner dome and aluminumframe. 6. Sealant tape.l'X.125"located between outer and Inner domes. 7. 6063-T6 extruded aluminum frame.Aluminum frame mitered and welded @ four comers. a '� 8. #12 X 1.75"Fastener.One fastener located equidistant from each comer.Four fasteners per skylight. m < b 9. #10 X.37518-8 stainless steel fastener.Located 4'from each comer,maximum 11'on center. 10. All units equal to or less than the total square footage or the test specimen,36 square feet,will be accepted under this approval. 11. Minimum distance=4"from angle Op to roof surface for shingles or BUR without Insulation.For Insulation and file roof add Ole height and Insulation thickness to 5 the 4'minimum height _ f (utter Polycarbonate Dome O3 a j Inner Polycarbonate Dome® y s=0 2 " V #12 Stainless Steel Fastener with a S neoprene gasket One fastener c P � 1 € located equidustant from each ® Sealant SO comer.(Four fasteners per �n o o�w�' skylight) W1 6j 3a Sealant Tape © p Sealant O #10 X 375"stainless steel fastener @ °wi 1�60 4'from each comer,maximum I I" O flit O2 .060"Extruded Aluminum Condensation Gutter on center. Retaining Angle R1 Minimum#12 wood screw with miSealant 0.060"Aluminum Frame O E O n O 1-38"embedment into substrate receiving poInL Installation holes 4" from each comer,maximum 10.5"on I center. 1-3/8"Min. Design Pressure: 60psf+/- Embedment fbE0�P8Ni"A!2 Digitally J r� signed by Robert J Roof deck and framing by others.All NIA E Amoruso roof details shall comply with Aa �.. Date: Chapter 15 of the Current Edition �'ww�" 20 FBC and Chapter 9 of the Cu03.05 Current Edition FRC. Curb Mount Model 10-08:31 -05'00, t � NOTICE OF PRODUCT CERTIFICATION o - CERTIFICATION NO: NI009198.01-R5 DATE: 12/30/2007 CERTIFICATION PROGRAM: Structural COMPANY: Maxim CODE: M-1256-1 - � -+ REVISION DATE: 08/21/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NANG approved certification label must be applied to the product to claim certification status. Please review and advise NAM if any corrections are required to this document. J COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Maxim Industries,Inc. Series"Dade Curbmount" 1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight Dallas,Texas 75212 Configuration:O Glazing:Exterior Dome-0.118"Hyzod Polycarbonate w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate w/4"rise Overall: W-414 DLO: W40" 1-1-814" H-810" SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure:+60/-60 psf Large Missile Impact Rated Product Tested By: Architectural Testing,Inc. Report No: ATI-01-43381.01 Expiration Date: December 31,2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel:(804)6845124 Fax:(804)6845122 Product Evaluation Report Rule 61G20-3 F.A.C. I Report No. 2000, Rev. 2 1 Project No. 418-0102 1 3/2/18 1 Page 1 of 2 Manufacturer Product Series.Model and/or Description Maxim Industries,Inc Series"DCM"Dade Curb Mount Skylight 1630 Terre Colony Court Series"DSF"Dade Self-Flashing Skylight Dallas,TX 75212 Code:Current Edition of the Florida Building Code including the 61"Edition(2017)Florida Building Code Compliance Methods: Product Approval Rule 61G20-3.005(1)(D)—Product Evaluation Report by a License Professional Engineer Product Installation Instructions: • MAX0001,Rev.C,dated 3/2/18,signed and sealed by Roberti.Amoruso,Maxim Industries,Inc.Series"DSF"Dade Self-Flashing Skylight,Installation Anchorage Details • MAX0002,Rev.C,dated 3/2/18,signed and sealed by Robert J.Amoruso,Maxim Industries,Inc.Series"DCM" Dade Curb Mount Skylight,Installation Anchorage Details Product Testing: • Architectural Testing Inc.Test Report No.01-43381.01,dated 01/29/03,signed and sealed by Steve Urich,P.E., testing to TAS 201-94,TAS 202-94 and TAS 203-94 Engineering Analysis Et Product Evaluation:The following engineering and/or rational analysis/calculations.have been performed. • Anchorage and product verification has been substantiated by calculation(PTC Report.No.1591,Rev.0)prepared, signed and sealed by Roberti.Amoruso,P.E.in accordance with the current edition of the Florida Building Code. • Design Pressure Evaluation/Product Evaluation o Drawing No.MAX0001&MAX0002 ■ High Velocity Hurricane Zone(HVHZ):YES ■ Outside High Velocity Hurricane Zone(HVHZ):YES ■ Impact Resistant:YES ■ Skylight domes using Covestro LLC Makrolon Polycarbonate Panels(Makrolono(formerly Hyzod®)is a trade name for Covestro(formerly Bayer Material Sciences). o Architectural Testing Inc.Test Report No.01-43381.01,dated 01/29/03,signed and sealed by Steve Urich, P.E. ■ Design Pressure Evaluation based on testing • Margin of Safety=positive loading 3 and negative loading 2 for plastic skylight domes applied to Structural Design Pressure per MD FAQ (http://www.miamidade.gov/building/products/skylights.asp)and meetingtexceeding current FBC requirements. +180/-120 psf Structural Design Pressure o 180/3=+60 psf&120/2=-60 psf DP • +9 psf Water Test Pressure equates to 6.06/.15=+60 psf DP • Cyclic Test Pressure per TAS 203 was+/-60 psf ■ Design Pressure=+/-60 psf o ,Performance and Testing Standards ■ TAS 201-94 ■ TAS 202-04 ■ TAS 203-94 �■.w.rrr PTC Product Design Group, LLC I PO Box 520775. Longwood, FL 32752-0775 ria• 321-690-1788 1 FBPE Certification of Authorization No. 25935