NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AIIJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(in
Miami-Dade County)and/or the AI-IJ(in areas other than Miami-Dade County)reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by
Miami-Dade County Product Control.Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the:Florida Building Code.
DESCRIPTION: Estate"S"Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: ".Miami-Dade County Product Control Approved unless otherwise noted herein.
RENEWAL.of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,.for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal.of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion.of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises MOA No. 16-0112.08 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy,Ventura
NOA No.18-0829.03
MAMRAM - Expiration Date: 08/23/21
Approval Date: 10/11/18
Page I of 7
ROOFING ASSEMBLY APPROVAI.
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Estate"S"Concrete,Roof Tile,as manufactured by Boral Roofing,LLC in
Okeechobee, FL as described in Section 2 of this Notice of Acceptance,designed to comply with the Florida Building
Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by
applicable Building Code,do not exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
Boral Estate'S' Roof Tile Length= 16-112" TAS 112 Low profile,interlocking, extruded
Width= 13" Type lb concrete roof the equipped with two nail
Class III hole and double roll ribs. For direct deck
or battened nail-on,mortar or adhesive
set applications.
Trim Pieces 1=varies TAS 112 Accessory trim,concrete roof pieces for
w=varies use at hips,rakes,ridges and valley
varying thickness terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee.FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name Product Description Manufacturer
(With Current NOA)
ICP Adhesives Polyse AH-160 Two component polyurethane ICP Adhesives and Sealants,Inc.
foam adhesive.
TILE BOND""Roof Tile Adhesive Single component polyurethane The Dow Chemical Company
foam roof tile adhesive.
DAP Foam Touch N Seal Two component polyurethane Dap Foam,Inc.
StormBone 2 Roof Tile Adhesive foam adhesive.
NOA No.18-0829.03
Mi(ANlFL�Olt1EC PITY Expiration Date: 08/23/21
Approval Date: 10/11/18
Page 2 of 7
2.3 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 PA 102 Dec. 1991
7161-03 PA 102(A) Dec. 1991
716.1-03 PA 108 Dec 1991
P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
P0631-01 PA 108 July 1994
Letter Dated Aug. 1, PA 108 Aug. 1994
1994
Professional Service Industries, Inc. 224-47099 PA 112 Sept. 1994
The Center for Applied 94-060B PA 101 March, 1994
Engineering, Inc 94-084 PA 101 May 1994
25-7094-1. PA 102 Oct. 1994
25-7094-7 PA 1.02 Oct. 1994
25-7094-4 PA 102 Oct. 1994
Project No.307025 PA 100 Oct. 1994
'fest#MDC-76
25-7183-1. PA 102 Feb. 1995
25-7183-2 PA 102 Feb. 1995
25-7214-2 PA 102 March, 1995
25-7214-6 PA 102 March, 1995
Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998
52010941 Dec. 1998
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
IBA Consultants,Inc. 2381-264 TAS 112 01/08/08
American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15
PR.I Construction.Material DAPF-004-02-05 TAS 101 07/26/18
Technologies DAPF-004-02-07 Static Uplift Resistance 07/26/18
i (Adhesive Set)
3. U IITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set the applications,a static field uplift test in accordance with TAS 106 may
required,refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 11.2,appendix`A'. Such testing shall be submitted to the Miami-Dade Product
Control Section for.review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No.18-0829.03
��u�fffiMtY Expiration Date: 08/23/21
;...r
Approval Date:10/11/18
Page 3 of 7
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Boral Estate"S"Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 11.8,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight(W) and Dimensions (I x w)
Tile Profile Weight-W(lbf) Length-1 (ft.) Width-w(ft.)
Boral Estate`S' Roof Tile 10.0 1.375 1 1.08
Table 2: Aerodynamic Multipliers-X(ft3)
Tile X(ft3) 1 (ft3)
Profile Batten Application Direct Deck Application
Boral Estate 'S' Roof Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity -Mg(ft.-lbf)
Tile 3":12" 4":12" 591:12" 6":12" Greater than
Profile 7`:12"
Boral Estate 'S' Battens Direct Battens Direct I Battens Direct Battens Direct Battens Direct
Roof Tile Deck Deck Deck Deck Deck
5.91 6.74 1 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
Table 4: Attachment Resistance Expressed as a Moment-Mt(ft-lbf)
for (Vail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19132" plywood)
Boral Estate 2-10d'Ring Shank Nails " 27.8 37.4 28.8
'S' Roof Tile 1-10d Smooth or Screw 8.8 11.8 4.1
Shank Nailz
_ _.
2-10d Smooth or Screw 16.4 21.9 7.1
Shank Nails _
1 #8 Screw2 _ 25.8 25.8 22.9
2#8 Screw 47.1 47.1 49.1
1-10d Smooth or Screw 24.3 24.3 24.2
Shank Nail Field Cli 2
1-10d Smooth or Screw 19.0 19.0 22.1
Shank Nail Eave Cli z 1
2-10d Smooth or Screw 35.5 35.5 34.8
Shank Nails (Field Clip)
2-10d Smooth or Screw i 31.9 31.9 32.2
Shank Nails Eave Clip)-
2-10d Ring Shank Nails' 1 43.0 _ 67.5 50.9
NOA No.18-0829.03
Expiration Date: 08/23/21
Approval Date:10/11/18
Page 4 of 7
I Installation with a 4"the headlap and fasteners are located a min. of 2'/a"from head of tile.
2 When using only one fastener use the hole that is approximately 4-314"away from interlocking edge.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft.-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Boral Estate'S' Roof Tile Adhesive
3 See manufactures component approval for installation requirements.
4 The Dow Chemical Co.TILE BOND'Roof Tile Adhesive weight per patty 11.4 grams. 26.1
5 ICP Adhesive and Sealants, Inc.ICP Adhesve Pol sett AH-160 Two-Component weight per patty 8 grams 26.1
6 DAP Foam Touch N Seal StormBond©2 Roof Tile Adhesive weight per paddy 8 rams. 35.0
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft.-Ibf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Boral Estate 'S' Roof Adhesive?
Tile
7 See manufactures component approval for installation requirements.
8 ICP Adhesive and Sealants, Inc.ICP Adhesve Pol set®AH-160 Two-Component weight per patty 54.grams. 86.61
9 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset@ AH-160 Two-Component weight per patty 24 grams 45.5.
10 DAR Foam Touch N Seal StormBondO 2 Roof Tile Adhesive weight per paddy 60 grams. 60.0
Table 7: Attachment Resistance Expressed as a Moment-Mf(ft.-lbf)
for Mortar or Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Boral Estate 'S' Roof Mortar Set 20.60
Tile
NOA No.18-0829.03
MIAMMAD£COl/fVTSr Expiration Date: 08/23/21
Approval Date:10/11/18
Page 5 of 7
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
Fr=
OR
Ij
E T E FFJ
BORAi,ESTATE'IS"TILE LABEL(LOCATED ON UNDERSIDE OF TILE)
G. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following;
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.18-0829.03
Expiration Date: 08/23/21
Approval.Date: 10111/18
Page 6 of 7
PROF[GE DRAWING
Nail Holes
16.112,,
1
BORAI..ESTATE"S"4 CONCRETE ROOF TILE
Esti) OF THIS ACCEPTANCE
EuanEcat�s7x NOA No.18-0829.03
t
� Expiration Date: 08/23/21
Approval Date:10/11/1.8