HomeMy WebLinkAboutDesign Pressure Calculations i
'RURRICARE WINDOWS
2253 Vista Pkwy#12
West Palm Beach,FL 33411
Property Information F Building Information
Owner: Alec Coffee Wind Zone: 170 MPH.
Address: 765 Lindo Lane Exposure Category: C
Port St Lucie,FL 34952 Minimum Building Dimension: 35 ft.
Mean Roof Height: 12 ft.
Risk Category: IJ
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft)IF Pressure(psfl Pressure(psf)
1 Int 24 47 7 37.8 -41.0
2 Int 47 47 7 36.7 -39.9
3 Int 24 47 7 37.8 -41.0
4 Int 31 25 7 37.8 -41.0
5 Int 31 25 7 37.8 -41.0
6 Int 39 37 7 37.8 -41.0
7 Int 39 37 7 37;8 -41;0
8 Int 39 37 7 37.8 -41.0
9 Int 39 37 7 37.8 -41.0
10 Int 39 37 7 37.8 -41.0
11 Int 71 36 7 36.4 -39.6
�I
' II
i
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.