HomeMy WebLinkAboutProduct Approval (3) -2/16/2018 Florida Building Code Online
li Its:
�L�LL7
BCIS Home I Login I User Registration Hot Topic Submit Surcharge Stats&Facts Publications I FBC Staff BCIS Site Map Links Search
Florida
e �� 'USER:ProductApproval
a p r REVIEWED FOR
elz T." CODE COMPLIANC
Product Approval Menu>Product or Application Search>Application List>Application Detail
-« FL ff FL6332-R8 F6��BO
N Y
Application Type Revision CX
Code Version 2017 ��9
Application Status Approved U�. 3 J
Comments S . Lucie County'permitting
Archived
Product Manufacturer ICP Adhesives&Sealants,Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs,FL 33065
(888)774-1419 Ext 201
rylipelkonen@icpadhesives.com
Authorized Signature Riku Ylipelkonen
rylipelkonen@lcpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roof Tile Adhesives
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 02/07/2021
Validated By John W.Knezevlch,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL6332 R8 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
SSTD 11 1997
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquanCtKft6P/a2fm%243ax6XpXuocOWKcLM2j%2bQ%3d 1/2
2/15/2018 Florida Building Code Online
Date Submitted 10/12/2017
Date Validated 10/14/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
SummarV of Products
FL# Model,Number or Name Description
6332.1 ICP Adhesives Polyset AH-160 Dual component expanding polyurethane roof the adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL6332 R8•11 2017 10 FiNAL ER iCP AH160 FL6332-
Approved for use outside HVHZ:Yes R8.odf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+n/a/-178 Created by Independent Third Party:Yes
Other:1.)The design pressure limitation in this application Evaluation Reports
refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R8 AE 2017 10 FINAL ER ICP AH160 FL6332-
2 of ER for all hip and ridge tile limitations.2.)Field tiles are R8.Ddf
designed based on overturning moment resistance. Refer to Created by Independent Third Party:Yes
Table 1 of ER for field tile limitations. 3.)Refer to ER Sections
5 for other Limitations of Use.
Back Nett
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please dick here.
Product Approval Accepts,
Credit Card
Safe
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquanCtKft6P/a2fMp/g2b3ax6XpXuocOWKcLM2j`/a2bQ%3d 2/2
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
-f RQOINIZY I ERD 353 CHRISTIAN STREET,UNIT 13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
ICP Adhesives and Sealants,Inc. Evaluation Report 02768.03.06-RS
12505 NW 44th Street FL6332-R8
Coral Springs,FL 33065 Date of Issuance:08/08/2008
(888)774-1419 Revision 8:10/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition(2017)Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words`Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
M00A."
�nrNngy.,�
��Cl•�sg:k
Robert J.M.Nieminen P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 ,!, Nieminen,P.E.on 10/12/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest
In any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives Polyset° AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 6th Edition(2017)Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2. STANDARDS:
Sections Property Standard Year
1504.2.1.1 Overturning resistance SSTD 11 1997
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) Static Uplift—SSTD 11 P39740.02.12 02/20/2012
ERD(TST 6049) Static Uplift—SSTD 11 P39740.11.13-R3 01/02/2015
ICC-ES(EVL2396) 2012 IBC Compliance ESR-1709 12/01/2016
Miami-Dade(CER 1592) HVHZ compliance 17-0322.03 04/27/2017
PRI(TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001
PRI(TST 5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005
PRI(TST 5878) Static Uplift—SSTD 11 PFI-006-02-02 05/09/2005
PRI(TST 5878) Static Uplift—SSTD it PFI-007-02-03 10/11/2005
PRI(TST 5878) Static Uplift—SSTD 11 PFI-008-02-04 02/21/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006
PRI(TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006
PRI(TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFPI-011-02-01 12/07/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFPI-012-02-03 12/07/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006
PRI(TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006
PRI(TST 5878) Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008
PRI(TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008
PRI(TST 5878) Static Uplift—SSTD 11 ECM-005-02-01 06/13/2008
PRI(TST 5878) Static Uplift—SSTD 11 ECM-006-02-03 06/13/2008
PRI(TST 5878) Static Uplift—SSTD 11 ECM-007-02-01 06/13/2008
PRI(TST 5878) Static Uplift—SSTD 11 ECM-008-02-03 06/13/2008
UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp.06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset®AH-160 is a two-component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders(ICP Adhesives ProPacko 30&100).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are,in anyway,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design,U.C. Evaluation Report 02768.03.06-RB
CertfrcoteofAothorfroNon#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-RB
ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017
Page 2 of 9
�J�
TRINI'T'Y J ERD
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset"AH-160 can be used with flat,low and high profile tiles or any rigid,discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local-level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local-level by the Authority Having Jurisdiction for use with ICP Adhesives
Polyset®AH-160.
5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to
projects having an Aerodynamic Uplift Moment(Ma), determined in accordance with FBC 1609.5.3 or Tables
2A and 21B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment
values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for
Adhesive Paddy Placement details.
TABLE 1: FIELD TILES IN ICP ADHEsivEs PoLysETO AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
2 TO 1 MARGIN OFsAFETYALREADYAPPLIED FOR INDEPENDENT(SINGLE OR CONTINUOUS PADDY)PLACEMENT
.4 T 1 MARGIN OFSAFETYAIREADYAPPLIED FOF INTERDEPENDENT(TWO DADDY)PLACEMENT
Tile(FBC 1609.5.3) Allowable
Type Profile Adhesive Paddy Placement Overturning
Moment(ft-lbf)
Independent;Single Paddy,Medium(2x7-inch,"30 gram) 60
Concrete Clay Flat Independent;Single Paddy,Large(2x10-inch,-45 gram) 112
Interdependent;Two Paddy(4x4-inch on underlayment,2x4-inch at the overlap) 54
Clay or Low/ Independent;Single Paddy,Medium(20-inch,"30 gram) 39
Concrete Medium Independent;Single Paddy,Large(2x10-inch,—54 gram) 67
Interdependent;Two Paddy(4x4-inch on underlayment,2x4-inch at the overlap) 58
Clay High Independent;Single Paddy,Large(2x10-inch,~45 gram) 134
Independent;Single Paddy,Medium(2x7-inch,"30 gram) 65
Concrete Clay High Independent;Single Paddy,Large(2x10-inch,-63 gram) 109
Interdependent;Two Paddy(4x4-Inch on underlayment,2x4-inch at tile overlap) 40
Clay Barrel 2x10-inch x`35 gram for pans;2 @ 140-inch x—17 gram for cap 147
Concrete Barrel 2x10-inch x`35 gram for pans;2 @ 1x10-inch x—17 gram for cap 107
ClayCap atop 2x Independent:Continuous Paddy stringer p y(^34 gram/ft) 135
Concrete Cap atop 2x Independent:Continuous Paddy
stringer p Y("34 gram/ft) 116
ClayCap atop 2x Interdependent: 105
I stringer I Head:One(1)#10 x 2W screw;Overlap:1 x 6 inch(^'10.5 gram)
Concrete Cap atop 2x Interdependent: 76
stringer Head:One(1)#10 x 2W screw;Overlap:l x 6 inch(^'10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90'underlayment system,as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local-level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Polyset®AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset®AH-160 shall be tested in accordance with SSTD it or Testing Application Standard
TAS 101. For the interdependent two-paddy method, an additional 2-to-1 margin above that specified in
SSTD it or Testing Application Standard TAS 101 shall be applied in determining the'allowable overturning
moment'.
Exterior Research and Design,U.C. Evaluation Report 02768.03.06-118
Certificate oJAuthoriration#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.6332-118
ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017
Page 3 of 9
VTRINrry!ERD
5.7 Hip and ridge tiles using ICP Adhesives Polyset®AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE 2:HIP&RIDGE TILES IN ICP ADHESIVES POLYSET"AH460
ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA
2 TO 1 MARGlNOFSAFETYALREADYAPPUEDFOR INDEPENDENT(CONrINUOUS PADDY PLACEMENT
4 TO 1 MARGIN OFSAFETYALREADV APPLIED FOR INTERDEPENDENT PLACEMENT
Allowable
Tile Substrate Attachment Method Design Pressure
(Psn
Clay 2x PT ridge board Independent:Continuous Paddy("34 gram/ft) 116
Concrete 2x PT ridge board Independent:Continuous Paddy(—34 gram/ft) 107
Clay 2x PT ridge board Interdependent:Head:One(1)#10 x 2Y"screw; 90
Overlap:l x 6 inch(`10.5 gram)
Concrete 2x PT ridge board Interdependent:Head:One(1)#30 x 2Y"screw; 56
Overlap:l x 6 inch(^'10.5 gram)
Clay or Hip&Ridge Channel Metal(FL5374):
Independent:Continuous Paddy("34 gram/ft) 169
Concrete galvanized only
Clay or Trim Lock`"(FL5374): aluminum, Independent:Continuous Paddy("34 gram/ft) 173
Concrete galvanized,Galvalume or stainless steel
Clay or Trim Lock'"Plus(FL5374): aluminum, Independent:Continuous Paddy("34 gram/ft) 178
Concrete galvanized,Galvalume or stainless steel
Clay Top Notch(FL8095) Independent:Continuous Paddy("32 gram/ft) 125
Concrete I Top Notch(FL8095) Independent:Continuous Paddy(^32 gram/ft) 146
6. INSTALLATION:
6.1 ICP Adhesives Polyset" AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section S.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012(04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants,Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
8. MANUFACTURING PLANTS:
Tomball,TX
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3623;LeAnna.Gradecki@ul.com
Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R8
CertiJ&ate o/Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118
ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017
Page 4 of 9
C
TRINITY ERD
10. PADDY PLACEMENT DETAILS(FROM ICP ADHESIVES AND SEALANTS,INC.PUBLISHED LITERATURE):
10.1 Independent,Medium Paddy:
Nail through plastic cement Paddy(Beneath Tile)
(when required) Nail through plastic cement
(when required)
Underlayment
Paddy(Beneath Tile)
Underlayment �-
7in.
i�2in.
Battens optional 21n. `
Eavetoursa Battensoptional
10inFascia 101n. ``'�` ' 21n.
4tin
Eave Closure
Eave Closure Eave Course Fascia
Flat/Low Profile Tile Medium Profile Tile
Nall through plastic c
(when required) Paddy(Beneath Tile)
Underiayment
.11 a
71n.
2 In.
Battensoptional
Eave Course `
Fascia
Weephole
loin. 2 in. Eave closure
Drip edge
High Profile Tile
Exterior Research and Design,LLC, Evaluation Report 02768.03.06-R8
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset°AH-160;(888)774-1419 Revision 8:10/12/2017
Page 5 of 9
Q0
TRINITY)ERD
10.2 Independent,Lame Paddy:
Nail through plastic cement Paddy(Beneath Tile)
(when required) Nail through plastic cement
(when required)
°
Undedayment (rte'
` f f�Paddy(Beneath Tile)
`\ ` 1
Undedayment
loin.
10i 'x
Battens optional �
2 in.wnle
Eavetourse Battensoptlonal
/
loin.
Fascia
Eave Closure
Eave Closure `� Eave Course Fascia
Flat/Low Profile Tile Medium Profile Tile
Nail through plasticc nt
(when required) Paddy(Beneath Tile)
Underlayment
/loin.x
2in.wide
Battens
optional
Eave Course Fascia
Weephole
10 in. 2 in.
Eave closure
Drip edge
High Profile Tile
Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R8
Certificate ofAuthori:ation#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polysete AH-160;(888)774.1419 Revision 8:10/12/2017
Page 6 of 9
TRININ I ERD
10.3 Interdependent,Two Paddy:
Nail through plastic cement Paddy(between tiles)
(when required) Nail through plastic cement Single paddy under file
(when required)
Battens optional ° Paddy(between tiles)
° Paddy(undertile)
'; Single paddy Battens P ddy(undert8e)
/ on top of tfle t- optional ,
4 x 4 in.
Singlopadd \ ., `�.,�` � Sin glepaddy
under t � on top of file\ ,,
Singlepaddy
on underlayment 2 x 4 in. ` / 4 x4 in. 2 x4 in.
° Single paddy on
E underlayment
Fascia 10 in. �`� tin.
EaveClosure
Eave Closure
Eave Course Fascia
Flat/Low Profile rile Medium Profile Tile
Nail through plastic ce`
Single paddy under tile
(when required)
Paddy(between tiles)
Battens ,t
optional Paddy(under tile)
Sing]*paddy �^
on underlayment {^ ^
4 x 4 in.
Single 23 n.
paddyont
top of tle
EaveCourse Fascia
weephole
loin. �2in. Eaveclosure
�. Drip edge
High Profile Tile
Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R8
Certificate oJAuthariration#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017
Page 7 of 9
TRINITY I ERD
10.4 Two Piece Barrel(Cap&Pan)Tile:
t)Place enough adheslwtoachieve 65to70sq.ln. Steep pitch applications
In contact with the pan tile. (when requited)
2)Tum Covers upside down.Place adhesive
112 I to i Inch In nom outside edge of cover tile.
Insall cover tile.
Ensure 20 to 25 sq.in-contact area on
each side of cover tile.
.r
IUnderlayment
.i'
y r+ sheathing
Eave closure
(motar shrwmI
Weephole Fascla III
Remove top portion of the ewe course cover tile.Abut to second course of
pan tiles.Ensure save end of pan and cover tiles are flush at eave line.
Two Piece Barrel-High Profile Tile
10.5 Hip and Ridge(independent placement):
2-
i
1
A bead or ICP P4*sm1tAH•l60 easy be e)1}r&d aiwt the Gchi To aucch Iri ndge u1n,a bead of ICP Pal)seIS A11.1-nayTo aaeb Up 4'e tin.a brat of PCT Pd1=FAN-160 wf do aMR9;w my
toe surtax eobo(b lidos of V tipetldge bold or Fahi lead be applird down the caner of for I/iptit@e bard of ph roved Ir 7"frd sM-de fA hry3 otter ne acs. i;,A—acb by 2 incl.m
uzeil Game In IMAI,yvalhestdoNing. frame. a..n.led a.
Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R8
Certificate of Author/2atlon09503 6'EDITION(2017)FBC NON•HVHZ EVALUATION FL6332-R8
ICP Adhesives Polysete AH-160;(888)774-1419 Revision 8:10/12/2017
Page 8 of 9
TRINITY ERD
10.6 Hip and Ridge(interdependent piacementh
f
1"X 6"Bead of ICP
Polyset®AH-160
roof the adhesive
#10 x 2-1/2"Screw
Code Approved
Fastener
Adhere starter
tile with a 2"x 7"
Paddy placed 3"
down from head
of the
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 02768.03.06-118
Certiftate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118
ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017