product Approval �/�
USER:Public User U
RE 0 DIED FOR
Product Approval Menu>Product or Aoclicatfon Search>Application List>Application Detail
CODE COMPLIANCE
RUM FL# FL2533-R22
Application Type Revision ST.
L dC I E C ���V
Code Version 2017
Application Status Approved B®CC
Comments
Archived
i
Product Manufacturer CertainTeed Corporation-Roofing
Address/Phone/Email 20 Moores Road
Malvern,PA 19355
(610)893-5400
mark.d.harner@saint-gobain.com
Authorized Signature Mark Hamer-
mark.d.harner@saint-gobain.com
Technical Representative Mark D.Harner
Address/Phone/Email 18 Moores Road
Malvern,PA 19355
(610)651-5847
Mark.D.Hamer@saint-gobalh.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
C Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/09/2020
Validated By John W.Knezevich,PE
W* Validation Checklist-Hardcopy Received j
Certificate of Independence FL2533 R22 CO! 2019 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6162 2008
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4470 2012
FM 4474 2011
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvwelwRFXRv... //24/14U 1 y
I
Florida Building Code Online* • Page 2 of 2
I
Sections from the Code
Product Approval Method Method 1 Option D j
Date Submitted 04/17/2019
Date Validated 04/21/2019
Date Pending FBC Approval 04/25/2019
Date Approved 06/18/2019
Date Revised 06/20/2019
Summary of Products
FL* Model,Number or Name Description
2533.1 Flintlastic Modified Bitumen Modified Bitumen Roof Systems
Roof Systems
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2533 R22 II 2019 04 FINAL Al ER CERTAINTEED MODBIT FL2533-
Approved for use outside HVHZ:Yes R22.odf
Impact Resistant:N/A Verified By: Robert Nieminen,PE PE-59166
Design Pressure:+N/A/-635 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Limits of Evaluation Reports
Use.2.)The design pressure noted in this FL2533 R22 AE 2019 04 FINAL ER CERTAINTEED MODBIT FL2533-
application relates to one specific system.Refer R22,pdf
to the ER Appendix for all systems and max Created by Independent Third Party:Yes
design pressures.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
ij
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvweIwRFXRv... 7/24/2019
I
NEmo etc.
TABLE. DECK `. AFPLiCATION :?TYPE LIESGRIPTION PAGE
1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5
18 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded insulation,Bonded Roof Cover 6-8
1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base insulation,Bonded Top Insulation,Bonded Roof Cover 9
1D Wood New,Reroof(Tear-Off)or Recover C - Mech.Attached Insulation,Bonded Roof Cover 10-11
1E Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 12-14
1F-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-17
1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-19
1G Wood New o of Tear-Off Non-Insu ated,Bonded Roof Cover 19
2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover 8 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 20-22
2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 23-27
2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 28-30
3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-38
3B Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 38
3C Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 39
4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 40-43
4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 44-46
4C Lightweight concrete New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47-52
4D Lightweight concrete Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 52
SA Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 53
5B Cementitious wood fiber New or Reroof(Tear-Off) A-2 Mech:Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54
5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 55
5D Cementitious wood fiber New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55
6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 56-58
6B Existing gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 58.59
6C Existing gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 59
6D Existing gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 60
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 61-67
7B Various Recover F Non-Insulated,Bonded Roof Cover 67
NEMO ETC,LLC Evaluat_io_n Report-3520_03.p4-R23 for FL2533-R22
Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23i 04%17/2019
Prepared by: Robert Nleminen,PE-59166 CertainTeed Fiintlastl&Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 1 of 67
ONEMOletc.
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof
deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in.Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round Insulation Plate,Trufast HD with Trufast 3"
Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
➢ Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG#12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round
Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and.
engage the tap flute of the steel deck.
Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG HD or CD-10 with OMG 3 in.Galvalume Steel Plate,Dekfast#14 or DekSpike with Hex Plate or 3"Round Insulation
Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot •
hole in accordance with the fastener manufacturer's published installation instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,GlasRoc Roof Board or gypsum-based roof board that meets the CIA requirements
of F.A.C.Rule 61620-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),
whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck
listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper
codified and/or FBC Approval documentation.
S. Preliminary insulation attachment for System Type D:Unless otherwise_noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016).
6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
D Hot asphalt(HA): Full coverage at 25-30 lbs/square
D Ashland Pllodeck(A-PD): Continuous 0.75 inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below.
D Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1 inch wide ribbons,12-inch o.c.
Y ICP Adhesives Polyset BOARD-MAX: Continuous 3-inch ribbons,12-inch o.c.
➢ ICP Adhesives Polyset CR-20: Continuous 2.5 to 3-inch wide ribbons,12-inch o.c.
Y Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
Millennium PG-1 Pump Grade Adhesive(M-PGI): Continuous 0.5 to 0.75-Inch wide ribbons,12-inch o.c.
➢ OMG OlyBond 500 or OlyBond Green(OB500): Continuous 0.75-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot)
D Note: When multiple loyers(s)of insulotion and/or coverboard are Installed in ribbon-applied adhesive,boards shall be staggered from layer-to-layer.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. •
7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system In the tables,then the
thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
D Ashland Pllodeck(A-PD)@ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch)
D Ashland Pliodeck(A-PD)@ 6-inch o.c. MDP -277.5 psf (Min.1.0-inch)
Y Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): MDP -120.0 psf (Min.1.0-inch)
ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min.1.0-inch)
Y Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.1.07inch)
D Millennium PG-1 Pump Grade Adhesive(M-PGI): MDP -157.5 psf (Min.1.0-inch)
OMG OlyBond 500(08500): MDP -45.0 psf (Min.0.5-inch Multi-Max FA3)
➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch 150 95+GL)
D OMG OlyBond 500(08500): MDP -315.0 psf (Min.0.5-inch ENRGY 3)
D OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch ACFoam 11)
NEMO ET[,LLC _Evaluation Report 3520_03.04-R23 for FL2533-R
ZZ Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 _
Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 2 of 67
ii
lk7NEMO I etc.
B. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined In accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention
Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth In Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3
enhancements.
---- 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no
rational analysis is permitted.
11. For.mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing
roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with
ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Concrete Deck or Recover Applications using System Type D,the insulation is optional.
14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced,refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches.
For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWC references,listings were established through testing over lightweight concrete cast using only foaming
agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted,use of these listings
in new construction or re-roof(tear-off)applications is at the discretion of the Designer of Record and Authority Having Jurisdiction.
15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
MODIFIED . •• . METHODS
REFERENCE 'LAYER INATERIAL APPLICATION:
BP-AA Base Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20
(Base and Pty sheets,Asphalt-Applied) Ply One or more Ftintgias Ply 4;Flintglas Premium Ply 6 Hot asphalt at 20-40 lbs/square
El
BP-AA2 Base Yosemite Venting Base Hot asphalt in 24-Inch diameter spots in
(Base,Spot-Asphalt-Applied)
30-inch grid pattern
BP-AA3 Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid
(Base,Spot-Asphalt-Applied) pattern noted herein.
BP-AA4 Base Yosemite Venting Base Hot asphalt In 9-inch wide ribbons spaced
(Base,Strip•Asphalt-Applied) as noted herein.
BP-CA2 Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Henry#903 Adhesive at 1.5 gal/square
BP CA3 Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Millennium Hurricane Force Membrane
Adhesive,beads spaced 6-inch D.C.
Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base
SBS-AA Ply One or more Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base halt at 20-40 lbs/square
as s care
(585,Asphalt-Applied) Cap Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P P /q
CoolStar;Flintlastic Premium FR-P;Flintlastic GMS;Flintlastic GMS CoolStar
NEMO ETC,LLC _ TH 3:
- - - - --Evaluation Report 3520.03.04-R23 for FL2533-RZ2
Certificate of Authorization#32455 6 EDITION(2017)FBC NON.HVHZ EVALUATION Revision 2k_64/17/2019--
Prepared by: Robert Nieminen,PE-59166 CertalnTeed Fiintiasticm Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 3 of 67
ONEMOletc.
TABLE 1F-2:WOOD!ECKS—NEW CONSTRUCTION, •• i s•RECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASESHEET,BONDED ROOF COVER
System Deck •' � Base Sheet' ` Roof Cover_(Note 15)`: MDP
No. (Note 1) Base.. Fasteners Attach, Ply Cap, (Psfl
— _ Giasbase;Flexiglas;Flintlastic Flintfast 3 in.Insulation Plates with (Optional)BP-
W-95 Min.15/32-inch plywood Base 20;Poly SMS Base;Ultra FlintFast#12 or#14;Trufast 3"Metal 6-inch o.c,at 4-inch lap and 6-inch o.c.in three AA,SBS-AA, SBS-AA,SBS- -97.5
at max 24-inch spans Poly SMS Base;Yosemite Venting Insulation Plates with DP or HD;OMG 3 (3),equally spaced,staggered center rows SBS-TA or TA or APPiTA_
Base in.Round Metal Plates with OMG#14 HD APP-TA
W-96 Min.15/32-inch plywood Flintlastic APP Base T CMG 3 in.Round Metal Plates with OMG 6-inch o.c.at 4-inch tap and 6-inch o.c.in three
at max 24-inch spans #14 HD (3),equally spaced,staggered center rows. APP-TA APP-TA 97.5
Glasbase;Flexiglas;Flintlastic Flintfast 3 in.Insulation Plates with (Optional)BP-
Min.15/32-inch plywood Base 20;All Weather/Empire 8-inch o.c.at 4-inch lap and 8-inch o.c.at three SBS-AA or
W 97 at max 24-inch spans y ans Base•Poly SMS Base'Ultra Poly Plates
s FlintFast#14;Trufast 3' Metal insulation AA,SBS-AA or 97.5
with Trufast HD (3)equally spaced,staggered center rows SBS-TA
SMS Base;Yosemite Venting Base SBS-TA
Glasbase;Flexiglas;Flintlastic
BP-AA,SBS-
W-98 Min.19/32-inch plywood Base 20;Poly SMS Base;Ultra Note 2 7-inch o.c.at 3-inch lap and 7-inch o.c.in three SBS-AA,SBS-
at max 24-inch spans Poly SMS Base;Yosemite Venting (3),equally spaced,staggered center rows SBS-TA or TA or APP-TA 105.0
Base APP-TA
Min.19/32-inch plywood OMG 3 in.Round Metal Plates with OMG
W-99 Flintlastic APP Base T #14 HD or Dekfast Hex Plate with Dekfast (3),a o.c.at aced,lap and d inch r r in three APP-TA APP-TA -105.0
at max 24-inch spans #14 (3),equally spaced,staggered center rows
Glasbase;Flexiglas;Flintlastic Flintfast 3 in.Insulation Plates with (Optional)BP-
W-100 Min.15/32-inch plywood Base 20;Poly SMS Base;Ultra FlintFast#12 or#14;Trufast 3"Metal 6-inch o.c.at 4-inch lap and 6-inch o.c.in four AA,SBS-AA, SBS-AA,SBS- -127.5
at max 24-inch spans Poly SMS Base;Yosemite Venting Insulation Plates with DP or HD;OMG 3 (4),equally spaced,staggered center rows SBS-TA or TA or APP-TA
Base in.Round Metal Plates with OMG#14 HD APP-TA
W-101 Min.15/32-inch plywood Flintlastic APP Base T OMG 3 in.Round Metal Plates with OMG 6-inch o.c.at 4-inch lap and 6-inch o.c.in four APP-TA APP-TA -127.5
at max 24-inch spans #14 HD (4),equally spaced,staggered center rows.
COLD-APPLIEDSYSTEMS:• - -
Glasbase;Flexiglas Base;
Min.15/32-inch plywood Flintlastic Base 20;All Weather J Flintfast 3 in.insulation Plates with
W-102 / p y Empire Base;Yosemite Venting FlintFast#12 or#14;Trufast 3"Metal 8-inch o.c.at aced, lap and 8-Inchen o.c.in three (Optional} SBS-CA1 -52.5
at max 24-inch spans Base;Flintlastic Poly SMS Base; Insulation Plates with DP or HD (3},equally spaced,staggered center rows SBS-CAS
Flintlastic Ultra Poly SMS Base
TABLE IG: ••t •ECKSNEW CONSTRUCTION O. •• •
SYSTEM TYPE F:NON-INSULATED,BONDED •• COVER
System Deck Rbof.Cover(Note 15) .'
No. Primer MDP(psf).
(Note 1). Base Cap
PIy
W-103 Min.15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA-H (Optional)SBS-TA,APP-TA SBS-TA,APP-TA 112.5
W-104 Min.15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA (Optional)SBS-SA SBS-SA -127.5
NEMO ETC,LLC
Evaluation Report3520.03.0C423 fog FC2533=R22—�
Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVH2 EVALUATION Revision 23:04/17/2019
Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 19 of 67
CertainTeed
Commercial Roofing Technical Product
SLA DIA MOND° BASE SHEET
SBS MODIFIED BITUMEN SELF ADHERING FIBERGLASS BASE SHEET i
FOR HOT ASPHALT AND TORCH APPLICATIONS
Product Product Use:Black Diamond®Base Sheet is designed for use as a heat-activated base ply
Information for modified bitumen or built-up roofing systems. It is suitable for use in the construction
of various types of membranes for both new construction and reroofing over a variety of
substrates. Black Diamond Base Sheet will provide additional strength, improved handling,
pliability and moisture resistance when used as the first ply over non-nailable and
insulated substrates. Black Diamond Base Sheet also may be used as a vapor retarder
} � under roof insulation.
Limitations:Black Diamond Base Sheet is attached by a self-adhering method. It is not
intended for attachment with hot asphalt, cold adhesive, coal tar pitch or mechanical
fasteners. Rolls should be stored upright off the ground and completely protected from the
weather. Roof decks must be structurally sound, dry, smooth and meet or exceed minimum
requirements of the deck manufacturer, local code and CertainTeed. Black Diamond Base
" Sheet is a self-adhering base sheet featuring apeel-off backing.
Product Composition and Features:Black Diamond Base Sheet is manufactured on a
dimensionally-stable,fiberglass reinforced mat that receives a coating of SBS modified bitumen
compound and is surfaced with fine mineral particles.The fiberglass base mat provides uniform
strength and moisture resistance. Black Diamond Base Sheet modified bitumen compound
y- provides increased durability with improved pliability and high-tack characteristics for smoother,
a�r
more uniform applications without the need of adhesives or hot asphalt.
Roll Dimensions: 39%"x 68'7" (225 square feet)
Nominal Coverage: Two squares
Approximate Weight: 78 lbs. per roll
Top Surface: Fine black mineral particles
Back Surface: Release film
Applicable Standards:Meets ASTM D1970 and ASTM D4601,Type 1. Black Diamond Base
Sheet is approved by Underwriters Laboratories for use in various Class A, B and C roof
assemblies, Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 2533
and FL 16709)and Texas Department of Insurance(RC-47).
Packaging:Black Diamond Base Sheet rolls are individually packaged in corrugated boxes.
Technical The following information represents typical average properties of Black Diamond Base Sheet.
Data Modred Bitumen Coating:Non-oxidized (flux) asphalt, blended with a compatible elastomeric
styrene-butadiene-styrene polymer and selected inert fillers.
Support Mat:Dimensionally-stable, fiberglass reinforced mat.
Test Description Test Method Results*
Thickness: ASTM D1970 1.4 mm(55 mils)
Tensile Strength: ASTM D5147
@ 73.4+/-3.6'F MD/XD 50/30 lbs./in.
H2O Absorption: 0.1%
Dimensional Stability. ASTM D5147 MD 0.1%/XD 0.1%
Adhesion to Plywood. ASTM D1970 30 lbs./ft.
Tear Resistance: ASTM D5147 MD/XD 80/50lbs./ft.
*NOTE:Published results are nominal production values confirmed by independent laboratory testing.
MADE X
U.S.A.
Product Roof systems constructed with Black Diamond Base Sheet as the base ply must be applied in
Application accordance with installation procedures listed in the CertainTeed Commercial Roof Systems
PP Specifications.The following information is intended for general information purposes only
and is not all-inclusive.
Preparation:Substrates to receive a roof system must be firmly attached, smooth, dry, clean
and free of sharp projections and depressions. Flashing details must be in place, ready to
receive roofing with roof accessories available prior to application of materials. Substrates
requiring priming must be primed with asphalt primer such as FlintPrime®and be allowed to,
completely dry. Substrates must provide positive drainage. Roof insulation must be tapered,,
to drains.
Installation:Black Diamond Base Sheet must be installed with 4"side laps and 6" end laps,
with end laps diagonally staggered not less than 3'apart. Black Diamond Base Sheet must be
applied to a clean, non-nailable substrate by peeling off the siliconized backer that exposes
SBS high-tack self adhesive surface which is normal) heat activated
a specially formulated Y
P Y 9
by the sun.Therefore, on hot sunny days, adhesion occurs quickly. In addition, mopping or
torching a finished membrane to the base is more than sufficient to induce the adhesive's I
bite and set. During cool weather, the top surface of the Black Diamond Base Sheet can be
heated in order to activate the adhesive at the bottom of the product. {
Precautions:Cold weather applications require special handling to prevent damage to the rolls
and ensure satisfactory installation. Do not apply roofing systems over improperly prepared
substrates or substrates that contain moisture. Self-adhered membranes can act as a vapor
barrier; it is the sole responsibility of the architect, contractor and owner to ensure adequate
and appropriate substrate and roof system ventilation.
Maintenance:CertainTeed Commercial Roof Systems do not require any additional
maintenance beyond normal roof maintenance procedures. CertainTeed recommends regular
roof maintenance and inspection to determine the condition of drains, flashings and other
similar items, and to prolong the life expectancy of the roof system.
Warranties CertainTeed offers Limited (product only) and No Dollar Limit(NDL, product and
workmanship)warranties.Warranty type and duration is dependent on roof system
configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors
are eligible to apply for NDL warranties on specific roof projects. For more information,
see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing
Technical Services.
Technical CertainTeed provides technical assistance in the design, selection, specification and
application guidelines of CertainTeed Commercial Roof Systems.Architectural and field
Assistance and representatives are available for consultation within each region. For more information, contact
Services CertainTeed Commercial Roofing Technical Services at 800-396-8134 x2.
Caution: Torch-down application of this product may create a risk of fire including smoldering fires.The
roofing applicator is solely responsible for ensuring and enforcing safe and proper application
Fire Hazard of CertainTeed products by competent and qualified personnel.Only properly trained roofing;
professionals are authorized to install this product. I
Never apply flame,directly to combustible materialsor allow the flame to enter into hidden or,
protected areas that may contain combustible materials. Follow all local code requirements. '
Have a Class A-B-C fire extinguisher available to each applicator.Thoroughly inspect the lobi
site whenever torching equipment;has been used .Be certain that all chances of a fiire'have ;[ .
been eliminated:
Refer tothe CertainTbed Commercial Roof Systems,
Specifications, sofi rn Roofing
Association(MRCA)CERTA proram,Natal LGaAsc aNatol Roofing
Contractors Association(NRCA),National Fire.Protection Association(NFPA), and Asphalt Roofing
Manufacturers Association(ARMA)for further information and safetyrecommendations. ,
ASK ABOUT ALL OF OUR OTHER CERTAINTEED® PRODUCTS AND SYSTEMS: CertainTeed Corporation