Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approvals
K at Reguta *. >- BCIS Home ( Log In ' User Registration Hot Topics Submit Surcharge Stats&Facts j Publications Contact Us BCIS Site Map Links Search • g Product Approval _ USER:Public User t � Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail A FL# FL18686-R3 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived C-3 Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Authorized Signature Michael Stieh mstieh@gaf.com I Technical Representative Michael Stieh Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 628-3000 mstieh@gaf.com Quality Assurance Representative Richard Weiman Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 RWeiman@gaf.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity I Evaluation Entity Miami-Dade BCCO-EVL Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 02/22/2023 Validated By Miami-Dade BCCO-VAL i i Certificate of Independence Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 Equivalence of Product Standards Certified By i Sections from the Code Product Approval Method Method 1 Option C Date Submitted 02/26/2018 Date Validated 03/16/2018 Date Pending FBC Approval Date Approved 03/26/2018 v � i F!�# � � �3 Model,Nul:tlber or Narnle f De:scr�pt,on �� Ev .�. 18686.1 FeltBuster High-Traction Synthetic Roofing Felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18686 R3 II 18-0119.15.pdf q Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO - EVL Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL18686 R3 AE 18-0119.15.Ddf Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do,not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: '- ® eCfieii. y �safe I MMIN, VAMM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T 78 31 -2 F -2 6 5 590 786 315 599 NOTICE OF ACCEPTANCE (NOA) ne'w.miamidadesov/economy GAF 1 Campus Drive Parsipanny,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been-reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance; if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, i for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed;by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA 16-1213.04 and consists of pages 1 through 10. The submitted documentation was reviewed by Hamley Pacheco,P.E. NOA No.: 18-0119.15 M i Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 1 of 10 i ROOFING COMPONENT APPROVAL i Cateaory Roofing Sub-Cateaorv: Underlayment Material: SBS/Polypropylene/Asphalt PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description WeatherWatch®Mineral 36"x 50' rolls ASTM D 1970 Granular surfaced modified,fiberglass reinforced, Surfaced Leak Barrier 36"x 66.7' rolls bituminous sheet material for use as a leak barrier Manufacturing underlayment in sloped roof assemblies. Location#1,9 Designed as an ice&rain shield. StormGuard®Film 36"x 66.7' rolls ASTM D 1970 Modified,fiberglass reinforced,bituminous sheet Surfaced Leak Barrier material for use as a high temperature leak barrier Manufacturing underlayment in sloped roof assemblies. Location#1,9 Designed as an ice&rain shield. LibertyTM SBS Self- 39 3/8"x 66' rolls ASTM D 1970 Self-adhering SBS roof membrane. Adhering Base/Ply Sheet ASTM D4601 Manufacturing Type II Location#1,9 Deck-Armor TI Premium 54"x 222' rolls ASTM D 226 A UV-stabilized polypropylene breathable Breathable Roof Deck 48"x 100' rolls Type II underlayment. To be used for roof deck Protection protection as an underlayment in sloped roof Manufacturing assemblies. Location#2 Tiger PaWTM Roof Deck 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Protection 48"x 100' rolls Type II underlayment.To be used for roof deck protection Ma as an underlayment in sloped roof assemblies. ocation#3,5,6 FeltBuster®High-Traction 8"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Synthetic Roofing Felt Type 1 underlayment.To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location#7,8 -Mateo ck 36"x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment.To Protection Type I be used for roof deck protection as an Manufacturing underlayment in sloped roof assemblies. Location#4 btlAht![�A[sQUN[Y NOANo.: 18-0119.15 .gry°a�, ' Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 2 of 10 i i PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description LibertyTM SA Glass Cap' 39_3/8"x 34' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Sheet ASTM D 6163 self-adhering SBS roof membrane. Manufacturing ASTM D 7530 Location#9 GAFGLAS®Ply 4 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahll Manufacturing (1 meter)Wide Type IV coating. Location#9, 10 GAFGLAS®F1exP1yTM 6 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlit Manufacturing (1 meter)Wide Type VI coating. Location#9, 10 i MANUFACTURING LOCATION: 1.Mt.Vernon,IN 2.North Bay,Ontario 3.Mission,British Columbia j 4.Pryor, OK 5.Qingdao,China 6.Charleston, SC 7.Spartanburg, SC 8.Dadra,India 9.Savannah, GA 10.Mobile,AL { i i i I NOA No.: 18-0119.15 drttl3wr Expiration Date: 02/22/23 w I Approval Date: 02/22/18 Page 3 of 10 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date i Intertek Testing Services NA Ltd. 3077464-01 ASTM D 1970 08/23/06 3090131 Wind Uplift and Self Sealability 08/23/06 100258583COQ-OIOA ASTM D 226 Type H 01/08/11 100673818COQ-003 ASTM D 226 Type II 06/13/13 10157289000Q-005 ASTM D 226 Type II 04/17/14 F8549.02-106-18 ASTM D 226 Type 1 11/08/16 PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07 Technologies,LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06 GAF-238-02-01 ASTM D 1970 03/03/10 GAF-323-02-01 ASTM D 1970 11/30/11 GAF-324-02-01 ASTM D 1970 12/01/11 GAF-325-02-01 ASTM D 1970 12/01/11 GAF-326-02-01 ASTM D 1970 11/30/11 GAF-275-02-01 ASTM D 1970 11/11/10 GAF-344-02-01 ASTM D 1970 04/23/12 GAF-339-02-01 ASTM D 226 Type I 03/14/12 ELK-311-02-01 ASTM D 1970 09/11/07 GAF-518-02-01 ASTM D 226 Type I 06/04/14 GAF-818-02-01 ASTM D 4533 12/06/17 GAF-829-02-01 ASTM D 226 Type II 01/15/18 GAF-314-02-01 ASTM D 2178 07/21/11 GAF-315-02-01 ASTM D 2178 07/21/11 Trinity-ERD GAF-SC13285.03.17-1 ASTM D 1970 03/08/17 GAF-SC13285.03.17-3 ASTM D 1970 03/01/17 GAF-SC13285.03.17-4 ASTM D_1970 03/01/17 GAF-SC13285.02.17-2 ASTM D 4601 Type II 02/08/17 GAF-SC9700.08-15-R1 ASTM D 2178 09/09/15 GAF-SC12915.12.17-R1 ASTM D 1970 12/11/17 GAF-SC12915.12.17-R1 ASTM D 6163 12/11/17 GAF-SC12915.12.17-R1 ASTM D 7530 12/1'1/17 i I NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page4, of 10 I 1 i APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 19/32" or greater plywood or wood plank i System E(1): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-Armoil Premium Breathable Roof Deck Protection,FeltBuster® High-Traction Synthetic Roofing Felt, or Tiger Paw'm Roof Deck Protection with a minimum 4" side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c:at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof.cloth duct tape(follow the tape's manufacturer's installation instructions).Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet,or LibertyTM SBS Self-Adhering Base/Ply Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch®Mineral Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier is acceptable. I Surfacing: Approved Roofing Assembly. i i i i I NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 5 of 10 I I l P' i I I I Deck Type 1: Wood,non-insulated Deck Description: 19/3? or greater plywood or wood plank System E(2): Membrane mechanically fastened to deck. Separator Sheet: One or more plies of GAFGLAS®Ply 4,GAFGLAS®FlexPlyTM 6, Shingle-Mate®Roof Deck Protection,Deck-Armoil Premium Breathable Roof Deck Protection,FeltBuster®High- i Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection loose laid. Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet,or LibertyT SBS Self-Adhering Base/Ply Sheet membrane mechanically fastened with a minimum 3"side lap and a 6"end lap to deck through the separator sheet with approved nails and tin caps 6" o.c.at the laps and two staggered rows 12" o.c. in the field of the roll. Surfacing: Approved Roofing Assembly. i I I I I N7Y NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page'6 of 10 i I T Deck Type 1: Wood,non-insulated I Deck Description: 19/3? or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier, ,LibertyTM SBS Barrier: Self-Adhering Base/Ply Sheet,LibertyTM SA Glass Cap Sheet,or StormGuardo Film Surfaced (Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base sheet.Do not overlap end or side joints.All side and end laps should be butted firmly side by side,flush with each other but not overlapped.Do not leave the WeatherWatch®Mineral Surfaced Leak Barrier, or StormGuard®Film Surfaced Leak Barrier membrane exposed for more than 30 days without a roof deck protection underlayment protecting the secondary water barrier. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type 11,Deck-Armor'Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin:caps 6" o.c.at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved Roofing Assembly. i I F 11FM1A,M�YD COMMNOA No.: 18-0119.15 ` Expiration Date: 02/22/23 Approval Date: 02/22/18 Page.7 of 10 i I } Deck Type 1: Wood,non-insulated Deck Description: 19/32° or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-Armoi'Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c.at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer?s installation instructions).Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of StormGuard®Film Surfaced Leak Barrier membrane with a minimum;4" side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Surfacing: Approved for Metal roofing,Slate, and Asphalt Shingle assemblies. I I I MutMtiA�� vHTx NOA No.: 18-0119.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 8 of 10 I I r LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self- Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armoi, Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be used as roof tile underlayment. I 3. This acceptance is for prepared roofing aPPlications. Minimum deck requirements shall be in compliance with applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SB'S Self-Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate'Roof Deck Protection, Deck-Armor TM Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable Building Code. 4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self- Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty— SBS Self- Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Arinofm Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes shall not be applied over an existing roof membrane. 6. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self- Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. 7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self- Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor' Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mateo Roof Deck Protection, Deck-Armoi' Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,and fire testing results. 8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45° F and rising. 9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. NOA No.: 18-0119.15 ,. Expiration Date: 02/22/23 Approval Date: 02/22/18 Page'9 of 10 LIMITATIONS. 10. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. i 13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or;logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. I MlA17C+0�llwi'C IAPPROVED[__ I END OF THIS ACCEPTANCE i i I I I NOA No.: 18-0119.15 MUIMMU4UE cOurm' � •,.� , Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 10 of 10 i 3/25/2019 Florida Building Code Online BCIS Home 1 Log In User Registration ( Hot Topics i Submit Surcharge Stats&Facts ( Publications ( Contact Us BCIS Site Map Links ` Search Flol ida 1 Product Approval :USER:Public User Product Approval Menu>Application Detail FL# FL18355-R4 } Application Type Revision { Code Version 2017 Application Status Approved Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com I Authorized Signature Kerri Eden kerri_eden@tamko.com i i Technical Representative Kerri Eden i Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Pqrofessional Engineer 17 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By Locke Bowden P.E. C Validation Checklist- Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shing es final.�df Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Equiv UL letter for standards for FBC 2017.pd http://www.floridabuilding.org/pr/pr app Idti.aspx?parwn=wGEVXQwtDquvosrHazGXQW83MMuofKzDIM2Xu9wuWmY6PQIJlukQ%3d%3d 1/2 I I 3/25/2019 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage, Heritage Premium, Heritage Woodgate, Heritage Vintage, Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18355 R4 II TBP15001.4 2017 FBC Eva] Report ShingLes Approved for use outside HVHZ:Yes final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other: See evaluation report for limits of use. Evaluation Reports FL18355 R4 AE TBP15001.4 2017 FBC Eval Report Shingles final.pdf Created by Independent Third Party:Yes Back tdext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 I The State of Florida is an AA/EEO employer.Coovright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®HE E Gredlt Card � I l http://www.floridabuilding.org/pr/pr_app!dti.aspx?param=wGEVXQwtDquvosrHazGXQW83MPI3uofKzDIM2Xu9wuWmY6PQljlukQ%3d%3d 2/2 Certificate of Authorization No.29824 CREEK 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERVICES; LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,r EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25,2017 220 West 4t"Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS Frederick, MD Dallas,TX Tuscaloosa,AL Duality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti Report No. Standard Year ' PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 1OCA50498 ASTM D 3462 2010A UL LLC(TST9628) 10CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e I UL LLC(TST9628) I 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FI-18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. I TAMKO BUILDING PRODUCTS CREEKAsphalt Shingles TECHNICAL SERVICES, LLC I � PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& j asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with j Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal j 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage@ 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules_I Joplin,Phillipsburg.& complying with ASTM D 3462. j Tuscaloosa) Heritage@ Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage@ Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Vintage@ 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules ' complying with ASTM D 3462. Heritage@ Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage@ Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed fierein. i I GOEEK TAMKO BUILDING PRODUCTS j� Asphalt Shingles TECHNICAL SERVICES, LLC eritage@ Basic Wind Speed(Vut): Max. 194 mph (Dallas, Frederick,Joplin, asic Wind Speed(Vasd): Max. 150 mph Phillipsburg&Tuscaloosa) eck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for I new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage@ Woodgate new construction; Min.7/16 in.OSB existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in.-exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or T Nail Pattern"detailed below. FASTENERS NAIL ZON E COMMON BOND fi-1l8" FMM U RE:T�- ff 12-1/211—►�+- 12-3/8" —►�r— 12-1/2"—►� �-1" I Figure 3. Herita e0 Herita e@ Premium and Herita e@ Wood ate(Dallas) 9 9 9 � 9 9 ( as) 4 Nail Pattern(non-HVHZ only) FASTENERSNAIL ZONE COMMON l BOND 6-118° EXPOSURE 6-318" 1 �-74/2'L*-7-1/2"-110�4- 74Z -*1--7-112"-►*-7-1/" Figure 4. Heritage@&Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. I GD TAMKO BUILDING PRODUCTS [� K Asphalt Shingles TECHNICAL SERVICES, LLC (BAR 20NE! ASTENERS 6M ON ¢BONt) a, 3 S-il8" ptPOSU�f 5 5l8" 1 �i/2= -7 i2 -7 -14-7117 9 �--1" Figure 5. Heritage@ Woodgate 6 Nail Pattern 12`112 - --►3 ¢{----1' 112"=-��1°t1��- ;Gom :Bond W — Figure 6. Herita e0 Herita e@ Premium &Herlta g e@ Woodgate Alternate 6 Nail Pattern FAINTI LINE 7718, G-1YI87 fi E.QGE O ; COMMC) 4 -BQN,D, � i EXR©SURE , •5.618", AtCEP']'.A13�LE . FASTEN ,,; 0 NOT FASTEN �1LC��IVG�Q=GE'OF w_ COMMON', 5 �:.. FASTENERO LO,CA'Tat�t� Figure 7. Heritage@(Tuscaloosa) - Expanded Nail Zone Nail patterns from Figures 3, 4,and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK` Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not: specifically addressed herein. I f I I GD TAMKO BUILDING PRODUCTS jj K Asphalt Shingles TECHNICAL SERVICES, LLC Heritage@ Woodgate Basic Wind Speed(V„it): Max. 194 mph (Frederick) Basic Wind Speed(Va,d): Max. 150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC 1 requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. ' I NAIL ZONE! COMMONBOND WT S-1I2° EXPOSURE S° 11" ..►�..-12-318" Figure 10. Heritage@ Woodgate(Frederick) 4-Nail Pattern (non-HVHZ only) NAIL ZONEI FASTENERS COMMON BOND t 5.1/2" EXPOSURE 5" ���9�318"�-►++1�3Ji- Figure 11. Heritage@ Woodgate(Frederick) 6 Nail Pattern TBP15001.4 FI-18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. ' I CD jl TAMKO BUILDING PRODUCTS 1 i 1 Asphalt Shingles TECHNICAL SERVICES,LLC Hip&Ridge Basic Wind Speed(Wit): Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind Stare h5-1/8" exposure 1 II Start Figure 1 here 5-1/B"exposure Fastener , Fastener Figure 21'4n Figure 3 Figure 14. Hip&Ridge(Frederick&Joplin) ' II I 1 i I TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK I Technical Services,LLC of Jany product changes or.quality assurance changes throughout the duration for which this report is valid. This evaluation report does,not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein! I j I