Loading...
HomeMy WebLinkAboutWack permit appAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 7/31/19 Permit Number: i IA R Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone; (772) 462-1553 Fax: (772) 462-1578 PERMIT TYPE: ELECTRICAL PROPOSED IMPROVEMENT LOCATION: Address: 18503 TRANQUILITY BASE LANE Building Permit Application Commercial Residential X Property Tax ID #: 3215-801-0074-000-7 Lot No, 21 Site Plan Name: WACK Block No, 3 Project Name: WACK DETAILED DESCRIPTION OF WORK: INSTALLING A 50 AMP DEDICATED CIRCUIT FOR A TESLA CHARGER AND SURGE PROTECTION IN PANEL CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: _Mechanical _ Gas Tank _ Gas Piping Shutters 4 Electric — Plumbing _ Sprinklers Generator Windows/Doors Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 715.16 Utilities: _Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name DAMON WACK Name.JOHN PANKRAZ Address:18503 TRANQUILITY BASE LANE Company: ELITE ELECTRIC AND AIR City: PORT ST LUCIE State: _ Address:1691 SW SOUTH MACEDO BLVD Zip Code: 34987 Fax: Cit PORT ST LUCIE y� State: FL Phone No.561-379-8941 Zip Code: 34987 Fax_ 772-340-3702 E-Mail: DWACK55@GMAIL.COM Phone No 772-340-3797 Fill in fee simple Title Holder on next page ( if different E-Mail PERMIT@ELITEELECTRICANDAIR.COM from the Owner listed above) State or County License EC13006036 If value of construction is 92snn nr mnrn a DPrnonen At c: ca.cNiCf1L 1a requirea. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Name:_ Address: City: Zip: Phone FEE SIMPLE TITLE HOLDER: Name:_ Address: City: Zip: Phone: Not Applicable MORTGAGE COMPANY: State �- Not Applicable X Not Applicable Name: Address: City: State: Zip: Phone: BONDING COMPANY: Name:_ Address: City:_ Zip: Phone: k Not Applicable OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated_ I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Signature of Ow / Lessee/Contractor as Agent for Owner Signature of Contra ense Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY QFsTLuc3e COUNTY OFsTcuclE The forgoing instrument was acknowledged before me this _1i_ day of ` U,,i 20 CA by JOHN PANKARZ Name of person making statement. Personally Known k OR Produced Identification Type of Identification Produced ,•ti sY'r,r;'', KOM LENAF DONITT Notary PubNc— State ofF4orida ` • Commission # GG 166915 omm, Expires yr Dec 10, 2621 (Signature of Notary Pub c-' I • i'f Fl t d uyniJafione 6 Commission No. ito(GejtS (Seal) REVIEWS FRONT ZONING SUPERVISOR COUNTER REVIEW REVIEW DATE RECEIVED DATE COMPLETED The forgoing instrument was acknowledged before me this 31 day of 'y�j+ `t 20 k4i by JOHN PANKRAZ Name of person making statement. Personally Known k Type of Identification Produced {Signature of Notary OR Produced Identification KONN# LENAE DEWITT Notary Public— State of Florida ` _ Commission # GG 166915 NolnryAssn. Commission No. G(iC,tfc'rr� _ m (Seal) . PLANS VEGETATION SEA TURTLE MANGROVE REVIEW REVIEW REVIEW REVIEW Electrical Load Calculations Project: At-Aop W r,, C it- Location: 1 �'�U 3 T O-AN (Uf err` (3AS+� LPrr` Existing Service Feeder Size: 24 -()Existing Panel Size: Uc) A Existing I Uda 2,0W 1 Sq. Ft. X 3 watts per sq. i1............................ (Q 7-Q i watts Appliance cir. @ 1500 watts each, ................... 30 ki o watts Laundry cir. @ 1500 watts each........... 5 U0 watts Range @ 8 kw ............................. 1000 watts Dishwasher and disposal @ 1500 watts each...... 3000 watts Microwave @ 2000 watts ............................ 1-ou t' watts Water heater @ 4.5 kw ............................... `� U,. watts Tankless water heater ............. p! 1 watts Dryer @ 5 kw ............................ 60PU watts Refrigerator @ 1500 watts .......... �-LV watts Bathroom 1 @ 1500 watts ............... watts Sprinkler Pump ........................................ M0() watts Other Other Pace L watts ..............watts Other ................ watts ,Sub total 3 , 11,C i Watts N&w Loads Poolpump ........................ . ...................... watts Pool light ................................. watts Heatpump ............................................... watts Chlorine generator.. ................. , watts Air blower .............................. watts Boatlift........................................ watts Other f 1✓ Sl C (44-'u rz 'rt... ............ t, is watts Other Other watts watts Total � �, �i� � Watts q),361 First l0 kw @ 100............................................. %_ it), Q U U watts 3 7, 31-1 Remainder @ 40%...................................................1 q, 4 /Y watts IUI�,$ A/C heat @ 100%.....................................................10, QQG watts Total watts 3 H r 5 qq Divided by 240 volts = N15 - %C 1 Amps Prepared by: YLL21 rGC .SVIIJ52_ Date: 1( 31 to The maximum power rating for the Wall Connector is 20 kW or 80A at 250V AC single-phase power. Voltage and Wiring SPeCifiCatiOTIS 208V or 240V AC single-phase: LI, L2, and earth Current Maximum output: BOA, 72A, 64A, 56A, 48A, 40A, 36A, 32A, 28A, 24A, 20A, 16A, 12A Frequency 50 to 60 Hz Cable Length 8,5' (2.6 m) and 24' (7,4 m) Wall Connector Dimensions Height: 15.0" <380 mm) Width: 6.3" (160 mm) Depth: 5.5" (140 mm) Top Entry Bracket Dimensions Height: 10.8" (275 mm) Width: 5.1 " (130 mm) Depth: 2.0" (50 mm) Weight (including bracket) 20 fb (9 kg) Operating Temperature -22°F to 1221F (-30°C to 50°C) Storage Temperature -40°F_to 185°F (-40°C to 85°C) Enclosure Rating Type 3R Agency Approvals cULus listed for United States and Canada under file number E354307, FCC Part 15. Ventilation Not Required ons 4. 5, Swrtch O OutputI Test mode N/A 12A 15A 2 16A 20A 3 20A 25A 4 24A 30A 5 28A 35A 6 32A 40A 36A 45A 8 40A 50A g 48A 60A A 56A 70A B 64A 80A C 72A g0A D 20A 100A E Not a valid selection N/A F Slave mode N/A Reattach the ribbon cable to the sealing cove r. Reinstall the sealing cover, Use a T20 security pin Torx driver to lightly secure the sealing cover by installing only the top screw, Turn ON power If the installation is successful, the LEDs briefly sequentially illuminate green with a pattern that ends with the top green LED staying solid ON. If there is a solid or flashing red LED, refer to Troubleshooting on page 22 and resolve the error before YOU continue, Note: To review the pattern of blinking lights, press and hold the RESET button for 5 seconds. S. Turn OFF power. 9. Write the contact information of the installer on the label 0n the inside of the Wall Connector. Secure the Cover and Power Up 1. Use a T20 security pin Torx driver to install the remaining screws on the sealing covet Ensure that the cover is properly aligned before fully tightening the screws. 2. Attach the outer cover to the sealing Cover starting with the latch at the top. Engage the snaps on the sides and align the mounting tab with the housing at the bottom, 3. Use a T10 Torx driver to install the screw that secures the bottom of the outer cover to the housing. 4. Close any unused openings with power and signal conduit plugs. Note: There should not be any visible openings to the inside of the Wali Connector, and the Wall Connector should be Completely sealed from the environment. 5. Turn ON the power. The installation is correct if the LEDs go through a sequence of flashing, ending with the top Green LEDs staying solidly ON. If there is a solid or flashing Red LED, resolve the error before you continue (refer to Troubleshooting on page 22). Note: To review the pattern of blinking lights, press and hold the Reset button for 5 seconds. 6. Attempt to charge the vehicle to ensure the Wall Connector is operating correctly and charging at the selected operating current. For instructions on how to charge, refer to the owner information provided with the vehicle. nstaliation Instructions 21 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 18503 Parcel ID: 3215-801-0074- Account #: 127362 TRANQUILITY BASE LN 004-7 Sec/Town/Range: i5/36S/38E Map 1D: 32/15X Zoning: AG-5 Use Type: 0I00 Jurisdiction: Saint Lucie County Ownership Legal Description Damon Wack Linda J Rubai.cava AERO ACRES BLK 3 LOT 21 (2.10 AC) (OR 1298-1272: 1700- 18503 Tranquility Base Ln 2151; 3081-1$) Port St Lucie, FL 34987 Current Values Historical Values 3-year Just/Market: $401,800 Assessed: $339,911 Year Just/Market Exemptions: $50,000 Taxable: Assessed Exemptions Taxable $289,911 2018 $401,800 $339,911 $50,000 $289,911 2017 $403,800 2016 $369,300 $332,920 $50,000 $326,073 $282,920 $50,000 $276,073 Date 04-08-2009 05-05-2000 06-01-1989 View: Year Built: 2001 Primary Wall: CB Stucco Bedrooms: 3 Full Baths: 2 Half Baths: 0 Sale History Book/Page Sale Code Deed Grantor 3081 / 0018 0116 QC Wack Damon 1298 / 1272 XX00 WD Noelke Dennis J 0641 / 1468 XX05 WD Walker David Primary Building Information Finished Area of this building: 2,087 SF Gross Sketched Area: 4,572 SF Roof Cover: Metal Frame: Story Height: 1 Story A/C %:100% Heated %: 100% Sprinkled %: 0% Type Driv-Concret UTILITY AVG POOL ENC-AVG CHAINLINK 4` SPA -HOT TUB RES POOL AVG POOL DK-AVG Exterior Data Roof Structure: Hip Grade: B No. Units: 1 luterior Data Electric: MAXIMUM Heat Type: FrcdHotAir Heat Fuel: ELEC Total Areas Price $100 $45,000 $36,500 Building Type: HB Effective Year: 2001 Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Carpet Finished/UnderAir 2,087 (SF): Gross Sketched Area 8,172 (SF): Land Size (acres): 2.1 Land Size (SF): 91,476 Total Building Count: 2 Special Features and Yard Items Qty Units Year Blt 0 1020 1999 80 1999 1614 2001 198 2001 1 49 2001 1 576 2001 1038 2001