HomeMy WebLinkAboutDrawing, layout .,,,� auawiaedaU
lf-ILE t��UF V
2
32" X 80"
47" X 80"
1
REPLACE DOOR&SIDELIGHT IN 1 OPENING
AND DOOR IN 1 OPENING ONLY.
NEW DOORS&SIDELIGHT TO BE IMPACT
RESISTANT-SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 47 80 26.11 4 36.1 -39.3 FL15505.2 50.0 -50.0 FRONT ENTRY-LSMI
2 32 80 17.78 4 37.8 -41.0 FL14569.1 66.0 -70.0 UTILITY/LAUNDRY ROOM-LSMI
REPLACE EXISTING DOORS&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
DOOR&SIDELIGHT FRAMES IN OPNG.#1 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= '12 FT 8 IN
LAAKKANEN RESIDENCE
212 S.E. CAMINO COURT DOOR REPLACEMENT PLAN
PORT ST. LUCIE, FLORIDA