Loading...
HomeMy WebLinkAboutDesign Pressure Calculations � - NewSouth WINDOWSOLUTIONS 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822 Property Information Building Information Owner: PATRICK GILLESPIE Wind Zone: 170 MPH. Address: 7103 WINTER GARDEN PARKWAY Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device EDevice Device Max Positive Max Negative Number Zone Width(in) Height(in) ElIFevation(ft) Pressure(psf) Pressure(psf) 1 Int 35.75 36 7 37.8 -41.0 2 Int 72.75 36.75 7 36.3 -39.5 3 Int 72.75 49 7 35.6 -38.8 4 Int 35.50 36.50 7 37.8 -41.0 5 Int 71.50 79.50 7 34.4 -37.6 6 Int 35.75 36 7 37.8 -41.0 7 Int 35.75 24.25 7 37.8 -41.0 8 Int 35.75 36.75 7 37.8 -41.0 9 Int 35.75 36.75 7 37.8 -41.0 10 Int 35.75 36 7 37.8 -41.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1