Loading...
HomeMy WebLinkAboutDrawing Identification Schedule for Opening Protective Device or System (Tlie following minimum information shall be provided to facilitate plan:review and inspection of the proposed installation,opening,protective device or system) Address: 3187 COLUMBRINA CIR, PORT SAINT LUCIE, FL 34952 Type of Structure: PERMIT#• Dev. Device Device Approval Opening Opening Shutter Shutter #Stonn Anchor Header # Type Manufacturer Width Height Width Height Bars Req. Spacing Reinf.Re 1. Accordion Town & Country FBC 13757 34 62.5 41 62.5 N/A 12" No 2. Accordion Town & Country FBC 13757. 34 62.5 41 62.5 N/A 12" No 3. NOT COVERED NOT COVERED No 4. Accordion Town & Country FBC 13757 68 62.5 75 62.5 N/A 12" No 5. Accordion Town & Country FBC 13757 34 62.5 41 62.5 N/A 12" No 6. Accordion Town & Country FBC 13757 50.5 62.5 62 62.5 N/A 12" No 7. Accordion Town & Country FBC 13757 68 63 75 63 N/A 12" No 8. NOT COVERED NOT COVERED No 9. NOT COVERED NOT COVERED No 10. Accordion Town & Country FBC 13757 34 62.5 41 62.5 N/A 12" No 11. Accordion Town & Country FBC 13757 34 62.5 41 62.5 N/A 12" No 12. Accordion Town & Country FBC 13757 19 43.5 27 43.5 N/A 12" No 13. Lexan Panel U1traTek FBC 39.5 12 14.25 44 N/A 12.5" No 14. Accordion Town & Country FBC 13757 34 62.5 41 62.5 N/A 12" No I ALL AMERICAN sHLTR1f vi_'.E R , GLASS 1636 Donna Read, Was4 Palau teach, FL,33466 (561) 712-9882 • wmallamerlcansh ulteis-cam Property Information Building Information Owner: ROY E.ARVIDSON Wind Zone: 170 MPH. Address: 3187 COLUMBRINA CIR Exposure Category: B PORT SAINT LUCIE,FL 34952 Minimum Building Dimension: 22 ft. Mean Roof Height: 10 ft. JU j Risk Category: II I Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) IL Elevation(ft) Pressure(psf) Pressure(psfl 1 End 41 62.5 7 30.0 -39.4 2 Int 41 62.5 7 30.0 -32.6 j 3 End 7 30.0 -32.6 j 4 Int 75 62.5 7 28.8 -31.4 5 Int 41 62.5 7 30.0 -32.6 6 Int 62 62.5 7 29.2 -31.8 7 Int 75 63 7 . 28.8 31.4 8 End 7 28.8 -31.4 9 End 7 28.8 -31.4 10 Int 41 62.5 7 30.0 -32.6 11 Int 41 62.5 7 30.0 -32.6 12 Int 27 43.5 7 31.2 -33.8 13 Int 14.25 44 7 31.2 -33.8 14 End 41 62.5 ^ 7 30.0 -39.4 I i i Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. j Page 1 of 1 Opening I Size (W x H) 1. ACCORDION 41 x62112 (WINDOW) 2. ACCORDION 41 x 62112 (WINDOW) 3. NOT COVERED (DOOR) 4. ACCORDION 75 x62112 (WINDOM j 5. ACCORDION 41 x 62 Vz 9 8 ` 1 A (WINDOW) 6. ACCORDION 62 x62 112 (WINDOW) 7 ACCO((WINDOM ON 75 x 63 7 S. NOT COVERED (SGD) r 9. NOT COVERED 10 -� (SGD) ' 10. ACCORDION 41 x 62112 6 •�� r� (WINDOW) r° ILM 11. ACCORDION 41 x 621/z (WINDOW) 11 12. ACCORDION 27 x43112 (WINDOW) 13. CLEAR PANEL 14114 x44 (WINDOIM � 5 14. ACCORDION 41 x 621h 12 13 (WINDOW) 04 4 0d 14 0 U J Z - 3 mLL_I -U EGRE a ? J 1 2 W OZ }, U 4 0 00 cn 0 a CaPYNGM E-T E".0 M SCALE: NOT TO SCALE DATE: Aug 02,2019 PAGE DESCNIPTbN: Site Plan y PAGE: GF1