HomeMy WebLinkAboutProduct Approval (2) 11 �
2/13/2018 Florida Building Code Online
tOKORRAMMUNT 00' "A
rA .;
BCIS Home Log In I User Registration Hot Topics Submit Surcharge stats&Facts I Publications FBC Staff BCIS Site Map Links Search 1
Florida
ProductApproval
USER:Public User
aopr R
Product Approval Menu>Product or Application Search>ApnlicaUon List>Application DetailRECEIVED
e * FL# FL20378-R1
Application Type Revision AUG 0 6 2019
Code Version 2017
Application Status Approved permitting
ST. Lucie County,
Comments
Archived
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990 (JA
(772)872-8034
flvalidation@yahoo.com
REVIEWED FpR
Authorized Signature Richard McKuhen CODE (�COMPLIANCE
�� P I A NCE
Technical Representative Richard McKuhen ST. LUCIE COUNTY
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990 S®Cpp��
Cti
2-8034
richa 87emfab. „
richard@emfab.net l//ate`
Quality Assurance Representative
Address/Phone/Email
Category Roofing
n'
Subat gory Metal Roofing
IY�+ ®��
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Ei Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL20378_RI COI FL 20378.1 NAILSTRIP 1.0 .032 ALUM sss.Ddf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDqua°/p2flMZ8n5CNV4ZYkew5Zoap/o2fEp/o2fovztglbhDVU2dJO4TAA%3dp/o3d 1/4
e �
2/13/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
FL# Model,Number or Name Description
20378.1 01-"1"Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1 II FL 20378.1 NAILSTRIP 1.0 .032
Approved for use outside HVHZ:Yes ALUM_sss.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1_AE FL 20378.1 NAILSTRIP 1.0 .032
instructions. ALUM sss.pdf
Created by Independent Third Party:Yes
20378.2 02-"1"Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.2 Extreme Metal Fabricators 26GA
Approved for use outside HVHZ:Yes NAIL STRIP 1.O.pddf,
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1 AE FL 20378.2 Extreme Metal Fabricators
instructions. 26GA NAIL STRIP 1.O.pi f
Created by Independent Third Party:Yes
20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_RI II FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1 AE FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.4 04-"1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378 RI II FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_RI AE FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.5 05-"Rib Panel" 29-gauge Steel exposed fastener roof panel,36"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.5 RIB 29GA ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_111 AE FL 20378.5 RIB 29GA_ssr df
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDqua°/"2f MZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 214
t .
2/13/2018 Florida Building Code Online
20378.6 06-"5V Crimp" 26-gauge Steel exposed fastener roof panel,24"wide,
mechanically attached to 15/32"Plywood or Wood Deck
w/fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1 II FL 20378.6 5V Crimp sss.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Method 1 and Method 2 FL20378_RI AE FL 20378.6 5V Crimp sss.Ddf
fastening. Limitations and Conditions of Use. Refer to Created by Independent Third Party:Yes
manufacturer's installation instructions.
20378.7 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips,fasteners and adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1 II FL 20378.7 JM STANDING SEAM ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.7 JM STANDING SEAM ssr.Ddf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.8 08-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
15/32"plywood or Wood Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1 II FL 20378.8_NORDMAN TILE 24GA ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_RI AE FL 20378.8 NORDMAN TILE 24GA ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.9 Nordman Tile Details-ssr.pdf
Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E. @ CBUCK Engineering P.E.
Impact Resistant: No #31242
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use.Refer to manufacturer's installation FL20378_RI AE FL 20378.9 Nordman Tile Details-ssr.Ddf
instructions. Created by Independent Third Party:Yes
20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached
to 15/32"plywood or Wood Deck with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.10 NORD TILT.032 ALUM-ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_RI_AE_FL 20378.10 NORD TILT.032 ALUM-ssr.Ddf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
Back NeM
Contact Us::2601 Blair Stone Road,Tallahassee-FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
echcrk -.®
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoap/o2fEp/o2fovztglbhDVU2dJO4TAA%3dp/o3d 3/4
f
141
Product , • • lManpfaetu'rer: ",Extreme • • •
¢' 2160 SW-Poeta Drive
Palm City, FL 34990
772,j87_2-8034
112. • • . , • • • 1 • + •
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule#61G20-3,
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec. 1507.4.2
Yield strength:40ksi:Attached to Wood Deck with screws.
16"Coverage
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener for Method 1 Attachment# 10 x 1"Pancake Head wood screw to penetrate j
3/16"thru 15/32" min. plywood deck
Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive
along male flange the full length of panel.
Underlayment: To be compliant with FBC Sec. 1507
Slope: Shall be in compliance with FBC Sec. 1507. 1.1
Install Details: Table A Allowable Loads METHOD 1 main field METHOD 2 perimeter
DESIGN PRESSURE* _. 1-69.25 PSF _ 421.75 PSF
FASTENER SPACING-ALONG ROWS - 6"O.C. _ _ _,_- 6"O.C.
FASTENER SIZE: #10 #10
ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to
install details)
Reference Data: HURRICANE TEST LABORATORY,L.L.C.#TST ID: 1527
Report#:0223-0313-02 TAS125-03(uL58o-o6/uL9897-o4l)
1 Report#: 0223-1015-06 TAS125-03(uL 58o-o6iuL 9897 o4l)
EQUIVALENCY;UL 1897-04 6 EQUIVALENT TO UL 189712 TEST STANDARD "DESIGN PRESSURE MARGIN OF SAFETY 2:1
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial interest iF\0n*1d6 p&6y manufacturing or distributing products
under this evaluation.
Locke Bowden,P.E.is not owned,operated,or controlled by any�4ngjeny trrta�ufectute�'�Gdistributing products under this
report.
FL 20378.2 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t'ed..
2. Minimum slope to be compliant with,Florida Building Code 2017 6t'ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-13
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6"'ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fastener,
#t10 Pancake-Head Scre
Nallstnp'Roof Pang _
r d
.f
aIa"ecaa seamAdhcsrro
15132"Wood Deck continuous along mate rib
(Rdcr to Tablo"A)
16"•0-c.
I
Wood Deck
integral Snap Lock
Seam Adhesive
4 Apply 3/8"bead Bostik Sealant
entire length of panel
along male flange
#10 x 1"