Loading...
HomeMy WebLinkAboutProduct Approval, underlayment r . s� MIAMI* io R` M ' MI4MI DADE'COUNTY e,:o �� —PRODUCT CONTROL SECTION ��( = 11805 SW 26 Street,Room 208 DEp ART_y�tT OF REGULATORY AN ECO_-ONHC RESOI4ItC (REIt)'° q G Miam�Fjodda 83175-2474 BOARD AND CODE ADMINIST RATION DIVISION J T(786)315-2590 F(786)315-2599 �� � ��� wwwmiamidade.¢oy/economy NOTICE OF ACCEPTANCE (NOA) Gulf Coast Supply&Manufacturing,LLC. CODE COMPLIANCE 4020 SW 449' Street T. LUCRE COUNTY II Horseshoe Beach,FL.32648 L File C0PV B 0 C C SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County-and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptarce,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:26 ga.Coastal SV Roof Panel LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and follow,ing statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein_ RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change `( in the applicable building code negatively affecting the performance of this product_ I i TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as.an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature_ If any portion of the NOA is displayed,then it shall he done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official_ This NOA consists of pages I through 5- The submitted documentation was reviewed by Alex Tigera. f� I _ NOA No.:14-0520.02 Expiration Date:08%21/19 Approval Date:08121/14 i Page'l of 5 T I ` i I ROOFING SYSTEM APPROVAL: Catesory Roofing Sub-Cateeorv: Metal,Panels (Non-Structural) Material: Steel Deck Type: Wood Maximum Design Pressure -156.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description 26 ga. Coastal 5V- I=varies TAS 110 Corrosion resistant,galvanized,preformed, Crimp Roof Panel w=26" Valspar coated,prefinisbed,metal panels) (24"coverage) h=3/8" Min-Thickness 0.018" (26-a a.) Min.Yield Strength: 67ksi Trim Pieces 1=varies TAS 110 Standard flashing and trim pieces. w=varies Manufactured for each panel width. Min-Thickness-0.018" (26ga-) I MANUFACTURING LOCATION: 1. Horseshoe Beach,FL. 2. Sebring, FL_ 3. Stuart,FL. EVIDENCESUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials VLS-004-02-01 ASTM G 155 02/22/13; Technologies VLS-005-02-01 ASTM G 23 02/22/13] Force Engineering&Testing Inc- 117-0065T-07A-C TAS 125 08/02/13 Farabaugh Engineering and T215-08A TAS 100 08/13/14 Testin,hic. I i NOA No.:14-0520.02 r�rtecourrtY Expiration Date:08/21/19 j Approval Date:08/21/14 Page'2 of 5 i APPROVED ASSEMBLIES: System A: 26 ga. Coastal-"V-Crimp Roof Panel Deck Type: Wood,Non-insulated Deck Description: New Construction 19/32"or greater plywood or wood plank,or for re-roofing 15/32"or greatiz ply-wood. Maximum Uplift See Table A below. Pressure: Deck Attachment: In I accordance with applicable Building Code, but in no case shall it be less than 8d ring shank shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32- thick(Minimum 15/32")the above attachment method must be in addition to existing attachment- Underlaymen Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4"side- lap and 6"end-laps.Underlayment sll O-e—lastened wt corrosion resistant tin-caps and 112 gauge 1 1/4"annular ring-shank nails,spaced 67'o.c.at all laps and two staggered rows 12" o.c.in the field of the roll.Or,any approved underlayment having a cu:rrentNOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Gulf Coast Supply&Manufacturing LLC's current published installation instructions. j Metal Panels and I stall the"26 ga. Coastal 5V-Crimp Roof Panel" and accessories in compliance with Gulf Accessories: Coast Supply&Manufacturing LLC's current,published installation instructions and details. Flashing-,penetrations,valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133_ Panelfasteners shall be 1-9-15 x 1-V7"self drilling, self tapping,hex head screws with sealing washer of sufficient length to penetrate through the sheathing a minimum Of3/16 inch. Fasteners shall be installed at a maximum spacing as listed in Table A below parallel to the slope. Fasteners shall be installed at a maximum of 12"o.c-at panel edge. See detail herein. TABLE A NLAxIMum, DESIGN PmEssums J Roof Areas Field Perimeter and Corner' Maximum Design Pressures -108.5sf -156.5 psf Maximum Fastener Spacing 12"o.c. 6"o.c. 1.Extrapolation shall not be allowed NOA No.: 14-0520.02 APPROVEDL Expiration Date: 08/21/19 Approval Date: 08/21/14 Pagi 3 of 5 LDUTATIONS 1. Fire classification is not part of this acceptance- refer to a current Approved Roofing Materials Directory for fir� ratings of this product- ' 1 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e.field,perimeters, and comers).Neither rational analysis,nor extrapolation shall be perrnitted for enhanced fastening at enhanced! pressure zones(i.e.perimeters,extended comers and comers). 3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in Ithe Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or lo-go, and the following statement: "Miami-Dade County Product Control Approved"or with the Mian-ii-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model. I COUNTY 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.:140520.02 APPROVED! Expiration Date: 08/21/19 Approval Date:08/21/14 Page 4 of 5 II i PROFILE DRAWINGS DETAd]L A 26 GA.COASTAL 5V-CRnvz.P ROOF PANEL 24" Coverage #9-15 x 1 112"Woodgrip Screw #9-15 x 1 1/2"Woodgrip Screw i 5V-Crimp Panel Moisture Barrier Plywood Decking - �(By others) (By others) SeeTable A Herein for Maximum Fastening Spacing All, '' `. 5V Panel j 7 � � I I END OF THIS ACCEPTANCE NOA No.: 14-6520.02 � JA •oeeoutrn► Expiration Date:08/21/19 Approval Date:68/21/14 Page 5 of 5