NOTICE OF ACCEPTANCE (NOA)
Gulf Coast Supply&Manufacturing,LLC. CODE COMPLIANCE
4020 SW 449' Street T. LUCRE COUNTY
II Horseshoe Beach,FL.32648 L
File C0PV B 0 C C
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County-and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptarce,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:26 ga.Coastal SV Roof Panel
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and follow,ing
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein_
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
`( in the applicable building code negatively affecting the performance of this product_
I i
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as.an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature_ If any portion of the NOA is displayed,then it shall he done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official_
This NOA consists of pages I through 5-
The submitted documentation was reviewed by Alex Tigera.
f�
I
_ NOA No.:14-0520.02
Expiration Date:08%21/19
Approval Date:08121/14
i
Page'l of 5
T I `
i
I
ROOFING SYSTEM APPROVAL:
Catesory Roofing
Sub-Cateeorv: Metal,Panels (Non-Structural)
Material: Steel
Deck Type: Wood
Maximum Design Pressure -156.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
26 ga. Coastal 5V- I=varies TAS 110 Corrosion resistant,galvanized,preformed,
Crimp Roof Panel w=26" Valspar coated,prefinisbed,metal panels)
(24"coverage)
h=3/8"
Min-Thickness 0.018"
(26-a a.)
Min.Yield Strength: 67ksi
Trim Pieces 1=varies TAS 110 Standard flashing and trim pieces.
w=varies Manufactured for each panel width.
Min-Thickness-0.018"
(26ga-)
I
MANUFACTURING LOCATION:
1. Horseshoe Beach,FL.
2. Sebring, FL_
3. Stuart,FL.
EVIDENCESUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials VLS-004-02-01 ASTM G 155 02/22/13;
Technologies VLS-005-02-01 ASTM G 23 02/22/13]
Force Engineering&Testing Inc- 117-0065T-07A-C TAS 125 08/02/13
Farabaugh Engineering and T215-08A TAS 100 08/13/14
Testin,hic.
I
i
NOA No.:14-0520.02
r�rtecourrtY Expiration Date:08/21/19
j Approval Date:08/21/14
Page'2 of 5
i
APPROVED ASSEMBLIES:
System A: 26 ga. Coastal-"V-Crimp Roof Panel
Deck Type: Wood,Non-insulated
Deck Description: New Construction 19/32"or greater plywood or wood plank,or for re-roofing 15/32"or greatiz
ply-wood.
Maximum Uplift See Table A below.
Pressure:
Deck Attachment: In I accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32- thick(Minimum
15/32")the above attachment method must be in addition to existing attachment-
Underlaymen Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4"side-
lap and 6"end-laps.Underlayment sll O-e—lastened wt corrosion resistant tin-caps and 112
gauge 1 1/4"annular ring-shank nails,spaced 67'o.c.at all laps and two staggered rows 12"
o.c.in the field of the roll.Or,any approved underlayment having a cu:rrentNOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation# 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with Gulf Coast Supply&Manufacturing LLC's current published installation instructions.
j
Metal Panels and I stall the"26 ga. Coastal 5V-Crimp Roof Panel" and accessories in compliance with Gulf
Accessories: Coast Supply&Manufacturing LLC's current,published installation instructions and details.
Flashing-,penetrations,valley construction and other details shall be constructed in
compliance with the minimum requirements provided in Roofing Application Standards RAS
133_
Panelfasteners shall be 1-9-15 x 1-V7"self drilling, self tapping,hex head screws with sealing
washer of sufficient length to penetrate through the sheathing a minimum Of3/16 inch.
Fasteners shall be installed at a maximum spacing as listed in Table A below parallel to the
slope. Fasteners shall be installed at a maximum of 12"o.c-at panel edge. See detail herein.
TABLE A
NLAxIMum, DESIGN PmEssums J
Roof Areas Field
Perimeter and Corner'
Maximum Design Pressures -108.5sf -156.5 psf
Maximum Fastener Spacing 12"o.c. 6"o.c.
1.Extrapolation shall not be allowed
NOA No.: 14-0520.02
APPROVEDL Expiration Date: 08/21/19
Approval Date: 08/21/14
Pagi 3 of 5
LDUTATIONS
1. Fire classification is not part of this acceptance- refer to a current
Approved Roofing Materials Directory for fir�
ratings of this product- ' 1
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e.field,perimeters,
and comers).Neither rational analysis,nor extrapolation shall be perrnitted for enhanced fastening at enhanced!
pressure zones(i.e.perimeters,extended comers and comers).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in Ithe
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or lo-go, and the following statement:
"Miami-Dade County Product Control Approved"or with the Mian-ii-Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model. I
COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.:140520.02
APPROVED! Expiration Date: 08/21/19
Approval Date:08/21/14
Page 4 of 5
II
i
PROFILE DRAWINGS
DETAd]L A
26 GA.COASTAL 5V-CRnvz.P ROOF PANEL
24" Coverage
#9-15 x 1 112"Woodgrip Screw
#9-15 x 1 1/2"Woodgrip Screw
i
5V-Crimp Panel
Moisture Barrier
Plywood Decking - �(By others)
(By others)
SeeTable A
Herein for Maximum
Fastening Spacing
All, '' `. 5V Panel
j
7
� � I
I
END OF THIS ACCEPTANCE