HomeMy WebLinkAboutProduct Approval,metal I&A
iww=
BCIS Home Log In I User Registration Hot Topics i Submit Surcharge I Stats&Fads Publications Contact Us BCIS Site Map I Links j,Search ( y
Florida
Product Approval
USER:Public User
r
ttti s aq�vuk^is
Product Apyroval Menu>Product or Application Search>epplica[lon List>Application Detail
o ■^ FL# FL21388-R2 v1 (7
«- Application Type Revision
REVIEWED FOR
Code Version 2017
Application Status Approved CODE COMPLIANCE
Comments ST. LUCIE COUNTY
Archived B®CC
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart,FL 34997
(772)872-8030
juan@dynamicmetal.net
File COPY
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
9 rY 9
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
LJ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A.Turner,P.E.,MBA
d; Validation Checklist-Hardcopy Received
Certificate of Independence FL21388 R2 COIDyn CQI.pdf
Referenced Standard and Year(of Standard) Standard Year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/20/2018
Date Validated 06/20/2018
Date Pending FBC Approval 06/27/2018
Date Approved 08/15/2018
i
I
Summary of Products
FL# Model,Number or Name Description
21388.1 1"Nailstrip-24 Ga Steel GalvalUme 1"Nailstrip,24 Ga Steel Galvalume non-structural roof panel,
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL21388 R2 II 213881D.pdf
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-206 Evaluation Reports
Other:Fasteners at 6"OC and 6"from ends. FL21388 R2 AE 213881E.pd
Created by Independent Third Party:Yes
21388.2 1-1/2"Nailstrip-.032 Aluminum 1-1/2"Nailstrip, .032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213882D,pdf
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-168.5 Evaluation Reports
Other:Fasteners 6"OC and 6"from ends FL21388 R2 AE 213882E.pdf
Created by Independent Third Party:Yes
i
21388.3 1-1/2"Nailstrip-24 Ga Steel 1-1/2"Nailstrip,24 Ga Steel non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213883D.pdf
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-153.5 Evaluation Reports
Other: Fasteners 6"OC and 6"from ends FL21388 R2 AE 213883E.pdf
Created by Independent Third Party:Yes
21388.4 1-3/4"Snaplock-.032 Aluminum 1-3/4"Snaplock-.032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213884D.pd
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-191 Evaluation Reports
Other:Field Installation Uplift DP: clips at 16"OC and 4"from ends FL21388 R2 AE 213884E.pdf
equals 146 psf(includes FS=2); Corner Installation Uplift DP: clips at Created by Independent Third Party:Yes
8"OC and 4"from ends equals 191 psf(includes FS=2)
21388.5 1-3/4"Snaplock-24 Ga Steel 1-3/4"Snaplock,24 Ga Steel non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213885D.pdf
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N?A/-243 Evaluation Reports
Other:Field Installation Uplift DP: Clips at 16"OC,equals-176 psf FL21388 R2 AE 213885E.pdf
(includes FS=2);Corner Installation Uplift DP: Clips at 8"OC,equals Created by Independent Third Party:Yes
243.5 psf(includes FS=2)
21388.6 5V Crimp-.032 Aluminum. 5V Crimp,.032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213886D.pdf
Approved for use outside HVHZ:Yes Verified By:Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-183 Evaluation Reports
Other:Fasteners at 12"OC and 6"from ends. FL21388 R2 AE 213886E.pd
Created by Independent Third Party:Yes
Oack Next
I
Contact Us:;2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.:;Privacy Statemen ::Accessibility at ::Refund S� tatement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.
Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,
2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with
the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address whichi6n be made
available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
r r; ® ebhsil M
Credit Card
Safe
OLTE S ENGINEERING
ENGINEERING, DRAFTING,CONSULTING
15211 971h Road N
West Palm Beach,FL 33412
Ph/Fx:(561)225-1982
PRODUCT EVALUATION
PRODUCT: DYNAMIC 1" NAILSTRIP 24 GAUGE STEEL ROOF PANEL (FLPA#21388.1)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The Dynamic 1" Nailstrip 24 Ga. Steel Roof Panel, manufactured by Dynamic Metals LLC, is a non-
structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Section 1507.4.3 of the 6th
Edition (2017) Florida Building Code. The panel has been tested per UL580-06 by Intertek-ATI,with results shown
in test report G1195.06-450-44,
Technical Documentation:
1. Drawing "NSS16"dated 6/18/18 , signed and sealed by Scott Wolters, PE.
2, Test Reports listed above by Architectural Testing, Inc. signed and sealed by Charles Anderson, PE.
3. Supplemental Calculations to support"NSS16" drawing, signed and sealed by Scott Wolters, PE,
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4), Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, for use outside
of the HVHZ.
Limitations: This panel is approved for use outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener spacing across panels: 16" O.C. (at nailstrip)
(Panels overlap with male/female snap fit)
Maximum Design Pressure: 206 psf.
Max. Fastener Spacing: 6"from ends, 6"max. O.C.
Min. Panel Fastener: #10-9x1" Panclip MTW fastener
5PrCIAIZI11\16 IN IMPACT F1E515fw'cuupiNvvku.5,5forr-FONTS, & WINDOWS
i
Underlayment: 1 layer of 30 Ib, organic felt paper with 4"overlaps
(or)
Any underlayment with a valid FLPA or Miami-Dade NOA
Fire Barrier: 1 layer of VersaShield with 4"overlaps
(or)
Any fire barrier with a valid FLPA or Miami-Dade NOA
Minimum Substrate: Y2 (15132" min)4-ply CDX Plywood, nailed to 2x rafters spaced 24" max,
Q.C. with 8d ring-shank nails spaced 4"O.C.
Other Limitations: Roof slope must meet requirements of FBC Section 1507.4.2.
Fire classification is not a part of this evaluation.
Shear diaphragm values are not a part of this evaluation.
Design of substrate is by others and is not a part of this evaluation.
If you have any questions or need more information concerning this approval please contact me.
CThank you,
icYote-F
o
FL PE# 62354
JUN 19
I
� _7 N 1-1r (ii -IiU�r IN, 1 Rpfi r•5l5A1tr fOPr " a VVINONV'-
I
I
I I
I
' ami
m
h C; �+
I
i
,�,
1 � 44
� iCi2
:3 O tQ {
n x
(( i
O I
Q
0
� 0
0 (D
X
I
I (
V
li
y DYNAMIC METALS Sr'F'a2
tY6LiERS
340 PIKE ROAD www.dynamicn',e_aLnet (COAs 27foa)
15211 4776 ROAD N • 'ru- _
\ G"JES PfitlA S€RGN.FL 337~2 F }:t561)6Z9-?2 1 uEss PA1,� SEACN.fl.33atz �{1N3� fi %T sUeuirra�
r m aH:(561)62)-7288 EMAIL::n,�o(wdyn,,r.,;ame-c;.rtet (ss1,225-1saz -
- PaINTS tssu�.ii FopREv.0 tense
C