HomeMy WebLinkAboutProduct Approval n�}r•.,�:"P,..,^.��rs1 {d ;z!�s` �cll V -'� 11:Z—
ec;
idjl L :ir� _d I O-t
_37
BCIS Home I Log In I User Registration I Hot Topics ; Submit Surcharge I Stats&Facts I Publications f Contact Us f BCIS Site Map } Links ! Search
Florida -
r
ProductApproval
1d USER:Public User
Product Approval Menu>Product or ADolication Search>Application List>Application Detail
FL# FL-17162-114
Application Type Editorial Change
Code Version 2017
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft.Myers,FL 33912
(800)432-2204 Ext 4305
jflesher@easternmetal.com
Authorized Signature, James Flesher -
jflesher@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation-&Management Institute
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/1.5.2/A440 2011
ASTM E1886 2005
ASTM E1996 2009
•TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 06/12/2018
Date Validated 06/14/2018
Date Pending FBC Approval
Date Approved 06/19/2018
Summary of Products
FL At Model,Number or Name Description
17162.1 Series 3000 Aluminum Impact Fixed Series 3000 Aluminum Impact Fixed Window with PVB
Window with PVB interlayer interlayer.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17162 R4 C CAC NI012095-Rl.Ddf
Approved for use outside HVHZ:Yes FL17162 R4 C CAC'NI012096-RI.Ddf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure:+85.0/-90.0 05/31/2024
Other:Maximum size of 120"x 48"at+70.0/-70.0 Installation Instructions
Maximum size of 48"x 54"at+85.0/-90.0 GLASS FL17162 R4 II 08-02310B .Ddf
INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R.Lomas,P.E.62514
FLORIDA BUILDING CODE ACCORDINGTO MIAMI-DADE FOR Created by Independent Third Party:Yes
KURARAYINTERLAYERS Evaluation Reports -
FL17162 R4 AE 513067B.Ddf
Created by Independent Third Party:Yes
17162.2 Series 3000 Aluminum Impact Fixed Series 3000 Aluminum Impact Fixed Window with Sentryglas
Window with Sentryglas interlayer interlayer
Limits of Use Certification Agency'Certificate
Approved for use in HVHZ:Yes FL17162 R4 C CAC NI012094.01-Rl.Ddf
Approved'for use outside HVHZ:Yes FL17162 R4 C CAC NI012094-R2.Ddf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure:+100.0/-100.0 05/31/2024
Other:Insulated Impact Glazing Type A: +95.0/-100.0 Installation Instructions.
Impact Only Glazing Type B: +100.0/-100.0 GLASS FL17162 R4 II 08-02309B .Ddf
INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R.Lomas,P.E.62514
FLORIDA BUILDING-CODE ACCORDING TO MIAMI-DADE FOR Created by Independent Third Party:Yes
KURARAY INTERLAYERS Evaluation Reports
FL17162 R4 AE 513066B.Ddf
Created by Independent Third Party:Yes
0 0
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement Accessibility Statement::Refund Statement -
Under Florida law,email addresses are public records.If you do not want your e-mail address released in-response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails,provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please piovide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,ES.,please click here.
Product Approval Accepts:
n] Mialli EE M
Credit Card
Safe
t�V 11r�-�V a v
_MdA Safe
NOTICE OF PRODUCT CERTIFICATION
- O Acca 6'
CERTIFICATION NO: N1012095-R1
DATE: 08/19/2014
MI CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
IFNY, CODE: 1783=1
REVISION DATE: . 04/29/2018
To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the.
product is active.and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has'been satisfied.A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAM if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series"3000"Aluminum Flange Frame
16341 Domestic Avenue Fixed Window(Low Design Pressure)
Ft.Myers,FL 33912 Configuration:O
Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090"
DuPont PVB Interlayer/3/16"Heat strengthened Glass or
IG-3/16"Annealed Glass/Laminate-3/16"Heat Strengthened
Glass/0.090"DuPont PVB Interlayer/3/16"Heat
Strengthened Glass
Frame: W-3048mm(120") H-1219mm(48")
DLO: W-2984mm(117.5") H-1 181mm(46.5")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-11 Class CW-PG70 3048 g 1219(120 x 48)-FW
AAMA 506-11 Design Pressure:3351 Pa(70 psf)
ASTM E1886-05/E1996-09 Negative Design Pressure:3351 Pa(70 psf)
TAS 201/202/203-94 Water Penetration Resistance Test Pressure:718 Pa(15.00 pst)
Wind Zone 4-,Missile Level D
Large Missile Impact Rated
Product Tested By: Certified Testing Laboratories,Inc.
Report No: CTLA 3010W-2/CTLA 3010W 2A CTLA 3010W-1/CTLA 3010W lA
Expiration Date: May 31,2024
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel:(804)68475124
Fag: (804)684-5122
�■■■■■NOTICE OF PRODUCT CERTIFICATION �■■��"
f,- c�RrrFic.
q4�p4
CERTIFICATION NO: N1012096-R1
DATE: 08/19/2014
" 1 x . f CERTIFICATION PROGRAM: Structural
COMPANY: . Eastern
CODE:- 1783-1
REVISION DATE: 04/29/2018
To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certificationrepresents product conformity to the applicable specification and
that certification criteria has been satisfied. ANAMI approved certification label mustbe applied to the product to claim
certification status. Please review and advise NAMi if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series"3000"Aluminum Flange Frame
1"6341 Domestic Avenue Fixed Window
Ft.Myers,FL 33912 Configuration:o
Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090"
DuPont PVB Interlayer/3/16"Heat Strengthened Glass or
IG-3/16"Annealed Glass/Laminate-3/16"Heat Strengthened
Glass/0.090"DuPont PVB Interlayer/3/16"Heat
strengthened Glass
Frame: W-1219mm(48") H-1372mm(54")
DLO: W-1181mm(46.5") H-13331nm(52.5")
SPECIFICATION PRODUCT RATING
AAN.[A/WDMA/CSA 101/I.S.2/A440-11 Class CW PG851219 x 1372(48 x 54)-FW
AAMA 506-11 Design Pressure:4069 Pa(85 pst)
ASTM E1886-05/E1996-09 Negative Design Pressure:4309 Pa(90 psi)
TAS 201/202/203-94 Water Penetration Resistance Test Pressure:718 Pa(15.00 Pso
Wind Zone 4-Missile Level D
Large Missile Impact Rated
Product Tested By: Certified Testing Laboratoriesi Inc.
ReportNo: CTLA 3010W-3/CTLA 3010W-3A CTLA 3010W-1/CTLA 3010W-1A
Expiration Date: May 31,2024
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE,INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804)684-5124
Fag:(804)684-5122
L. Roberto Lomas P.E. Engineering'Evaluation Report
1432 Woodford Rd.
Lewisville,NC 27023 Report No.: 513067B
434-688-0609
rllomas@lrlomaspe.com
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave.
Ft.Myers,FL 33912
Product Line: Series 3000 Aluminum Flange Frame Impact Fixed Window—HVHZ-PVB
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the-Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document:drawing number 08-02310 Revision B,prepared,signed and sealed by Luis Roberto Lomas
P.E.
2. Test report No.:CTLA 3010W 2&-3 signed and sealed by Ramesh Patel P.E.
Certified Testing Laboratories,Orlando,FL
TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4
TAS 202-94 Uniform Static Air Pressure,t70.0psf design pressure,15.Opsf water penetration(120"x48")
+85.0/-90.Opsf design pressure, 15.0psf water penetration(48°x54°)
TAS 203-94-Cyclic Pressure loading t70.0psf(120°x48°) I
+85.0/-90.0psf(48°x54°)
3. Report No.:CTLA 301 OW-2A&-3A signed and sealed by Ramesh Patel P.E.
Certified Testing Laboratories,Orlando,FL
AAMAMDMA/CSA 101/I.S.2/A440-11
Design pressure: V0.0psf(120"x48")
Water penetration resistance 15.Opsf +85.0/-90.Opsf(48°x54")
"ASTM E1886-05 and ASTM E1996-09
ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 4
ASTM E1886/E1996 Cyclic Load Test,t70.0psf(120"x48°)
+85.0/-90.Opsf(48"x54°)
4. Anchor calculations,report number 513067-1A,prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
Maximum design pressure: t70.0psf(120"x48°)
+85.0/-90.Opsf(W.x54")
• Maximum unit size: 120"x 48"and 48"x 54"
• Units must be glazed per ASTM El 300-04/09,according to glazing details in approval drawing.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection In wind borne debris regions:
• Frame material to be aluminum.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document 08-02310
Revision B.
Certification of Independence: N��� S R•• t`� ��j/
Please note that I don't have nor will acquire a financial interest in any company ANN J`•
manufacturing or distributing the product(s)for which this report is being issued.Also,1 � �• �►�C'E S� •� �_
don't have nor will acquire a financial interest in any other entity.involved in the approval 4-. TJ 0 51 •
process of the listed product(s). * c •
T 41= •
��
ii��Fs
0RI
.'c•COP G�
�� O1VAL�����`
1 of 1 Luis R.Lomas,P.E.
FL No.:62514
01/10/2018
REVISIONS
2" MIN. Tr
EDGE DISTANCE REV DESCRIPTION DATE APPROVED
A REVISED INSTALLATION DETAILS 06/22/15 R.L.
CONCRETE/MASONRY — 01/10/la R.L.
BY OTHERS ?4•4 8 REVISED PER NEW REQUIREMENTS
1 1/4" MIN.
I . I EMBEDMENT
OPTIONAL IX BUCK4 1/4"1
MIN.
SEE NOTES 3-7 SHEET I EMBEDMENT
CONCRETE/MASONRY
BY OTHERS
APPROVED 1/4" MAX. 1/4" MAX.
SHIM SPACE OPTIONAL 1X BUCK
SEALANT SEE NOTES 3-7 SHEET I SHIM SPACE
BEHIND FLANGE tr
1/4" TAPCON
1/4" TAPCON
INTERIOR
2"
MIN.
EXTERIOR INTERIOR EDGE
DISTANCE
EXTERIOR
APPROVED SEALANT
BEHIND FLANGE
JAMS INSTALLATION DETAIL
1/4" TAPCON CONCRETEAMSONRYINSTALLATION
APPROVED
SEALANT NOTES:
BEHIND FLANGE 1.INTERIOR AND EXTERIOR FINWEA BY OTHERA
1/4" MAX. NOT SHOWN FOR CLARITY.
OPTIONAL lX BUCK SHIM SPACE 2.PERhVETERANDJOWTSEALANTSVOrlIERSTOSE
SEE NOTES 3-7 SHEET 1 DESIONEPINACCORDANCEIN1THASIME2112 SIGNED.0111812018
CONCRETE/MASONRY En-stern eASTIMNINALSUMLY 0
4 4' 4, ===11 MO OCUMM
BY OTHERS
4, W-7 ... "O'U"M
1 1/4" MIN.
EMBEDMENT SERIES 3000 ALUMINUM, FLANGE FRAME 05j
IMPACT FIXED WINDOW - HVHZ - PVB
FLANGE INSTALLATION DETAILS TAT OF *.t4:=
0.
Dwc;NO, Rev
DRAWN: cl
2J.L. 08-02310 L z
I
MIN. —T
EDGE DISTANCE S
CALE NTS 1"AlE 07/24/14 5 OF 5
VERTICAL CROSS SECTION L ROBERTO ILOAt4S RISE Luis R. Lomas P.E.
CONCRETEINASONRYINSTALLATION 1432 WOODFORD ROLMSVI"N027023 FL No.: 82514
+—} 5/8" MIN. REVISIONS
EDGE DISTANCE5/8" MIN. REV DESCRIPTION DATE APPROVED
WOOD FRAMING METAL EDGE DISTANCE A REVISED INSTALLATION DETAILS 06/22/15 R.L.
OR 2X BUCK 1 7 16" MIN. STRUCTURE B REVISED PER NEW REQUIREMENTS 01/10/18 R.L.
8Y OTHERS EMBEDMENT BY OTHERS
/4" MAX.
NS
SHIM SPACE
1/4" MAX. 5/8APPROVED 1/4MAX. APPROVED SHIM SPACESEALANT SHIM SPACE SEALANT EDGE INTERIOR
BEHIND FLANGE BEHIND14" SMS OR
�j14 WOODSELF DRILLING 14" SMS OSCREW SCREW SELF DRILLINSCREWMETASTRUCTURBY OTHEREXTERIOR
APPROVED SEALANT
BEHIND FLANGE
INTERIOR EXTERIOR PvV INTERIOR JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
EXTERIOR 1 7/16" MIN. 1%4" MAX.
EMBEDMENT ' SHIM SPACE
5/13" MIN.
EDGE DISTANCE
T - INTERIOR
.I
X14 WOOD r 14" SMS OR #14,WOOD
SCREW SSELF CREW DRILLING SCREW /
APPROVED APPROVED WOOD FRAMING -� EXTERIOR
SEALANT 1/4'MAX SEALANT MAX. OR 2X BUCK
�_ APPROVED SEALANT
BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4 SHIM"SPACE BY OTHERS BEHIND FLANGE
WOOD FRAMING METAL JAMB INSTALLATION DETAIL
OR 2X BUCK 1 7/16" MIN STRUCTURE WOOD FRAMINGOR2XBUCKINSTALLAT/ON
BY OTHERS BY OTHERS
EMBEDMENT SIGNED:01/18/2018
5/8" MIN.
EDGE DISTANCE r�►� y�e¢ g� °ASE ao of 5"R°' \111111I1I
5/8" MIN. ■ �6/a7La�i�'MO w,CI+NNETALSUwn ����\`` R LO/Y��i
EDGE DISTANCE • VERTICAL CROSS SECTION "�A�,^w,. ^_r��"�t�� Fes* n +2 �J\S GEN
VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION
WOOD FRAMING OR2XBUCK INSTALLATION SERIES 3000 ALUMINUM FLANGE FRAME 0
IMPACT FIXED-WINDOW — HVHZ — PVB �(, �1_
FLANGE INSTALLATION DETAILS TAT OF tv—
NOTES: DRAWN: Dwa NO: aEV ��O'F•'cfpRtot.
. s--ORV .
NO1.�HOWNFORRIOR EITERIO FINISHES,BY OTHERS, SCA!E 11.17E 08502310 B
2.PERIMETER AND JOINT SEALANT BY07HERS TO BE
NTS 07/24/14 4 OF 5
DESI(WEDINACCORDANCEWITH ASTME21f2 L.ROBERTO LOMAS AE Luis R. Lomas P.E.
1432 WOODFORD RD LEWISWLLE,NC27023
434.838-0609 rllomas@lAomasga.com FL No.: 62514
REVISIONS
REV DESCRIPTION DATE APPROVED
- 1 1/32" - 1 1/32"
A REVISED INSTALLATION DETAILS 06/22/15 R.L.
3/16" ANN 3/16" IIS 3/16" TEMP 3/16" HS
B REVISED PER NEW REQUIREMENTS 01/10/18 R.L.
.090 PVB BY KURARAY .090 PVB BY KURARAY
WEDGE GASKET316" HS WEDGE GASKET 3/16 HS
2541 BY MPI / 2541 BY MPI
FPVC 65 DUROMETER DURASEAL FPVC 65 DUROMETER DURASEAL
SPACER SYSTEM SPACER SYSTEM
SEETING BLOCK (30096) BY OUANEX SEETING BLOCK (30096) BY OUANEX
85 DUROMETER STRUCTURAL SEALANT 85 DUROMETER STRUCTURAL SEALANT
BY CENTRAL RUBBER SIKAFLEX 552 BY CENTRAL RUBBER SIKAFLEX 552
EXTRUSIONS EXTRUSIONS
EXTERIOR INTERIOR EXTERIOR INTERIOR
3/4" BITE 3/4" BITE
77
GLAZING DETAIL A I GLAZING DETAIL A
WHEN USED OUTSIDE THE HVH2 WHEN USED IN THE HVHZ
7/16•,
3/16" HS
WEDGE GASKET .090 PVB BY KURARAY
2541 BY MPI 3/16" HS
FPVC 65 DUROMETER
SETTING BLOCK (30096)
85 DUROMETER STRUCTURAL
BY CENTRAL RUBBER SEALANT
EXTRUSIONS SIKAFLEX 552
EXTERIOR A
3/4" BITE INTERIOR
GLAZING DETAIL B
SIGNED.01/18/2018
gq ® AbrAM
EASTERNARCIMCIMPALsstEALs
��►� ArdI�e ter/� ARNN
EEMMSTANL SUPPLY \\�\S R• L077ji/
- - 16NI DWESTICAVE \\\J\
`eomx ,FLar�u `V�•\�CENS`�
SERIES 3000 ALUMINUM FLANGE FRAME ;*�•/�1 aEE
IMPACT FIXED WINDOW — HVHZ — PVB ^,o y([{I�riHc„�sL07�EE
GLAZING DETAILS �7�. $TATEE OF
J
�
L.
/0NA 1
DWC No. 08-02310 RB
SCALE NTS DATE 07/24/14 s"EET 3 OF 5 71�\\\�
LROBERTOLOMASP.E. Luis R. Lomas P.E.
1432WOODFORDRDLEWISVILLE,,NC27023 FL No.: 62514
434.698-0509 r9omas@IAamaspe.com
e
REVISIONS
120" MAX FRAME WIDTH
• REV DESCRIPTION DATE APPROVED
4" MAX A REVISED INSTALLATION DETAILS 06/22/15 R.L.
4" MAX 8 REVISED PER NEW REQUIREMENTS 01/10/18 R.L.
8" MAX 4" MAX 4' MAX 48" MAX FRAME WIDTH
6' MAX D.C. - 6" MAX 6" MAX 12" MAX O.C. 6" MAX
6" MAX —�
/M 6" MAX 41
12' -�
O.C. /
48"
MAX / / 46 X
FRAME / MAX
HEIGHT D.L.O. 54"
MAX 52 1 2
"
/ FRAME MAX
HEIGHT D.L.O.
6" MAX 10 1/2" \
MAX O.C.
8,. -� �-
6" MAX MAX
O.C. 4" MAX 4" MAX 6" MAX
4" MAX 4" MAX 46 1/2" MAX D.L.O.
117 1/2" D.L.O.
DESIGN PRESSURE RATING IMPACT RATING '
DESIGN PRESSURE RATING IMPACT RATING
LARGE SERIES 3000 PW FIXED WINDOW 185.0%90.OPSF MISSILE MPACT
RGE
f70,OPSF MISSILE/MPACT EXTERIOR VIEW
MISSILE LEVEL D,WIND ZONE 4 AND HVHZ
MISSILE LEVEL D,WIND ZONE 4 AND HVHZ
SIGNED:01/18/2018
/9/EaAMMMOF
,'
ster/ ASTER}ViAARWFAL
LS1I1R14 R. l0
\imrlDawecAVQ
rL31v vJ �
��.
• S
SERIES 3000 ALUMINUM FLANGE FRAME 0 61
IMPACT FIXED WINDOW - HVHZ - PV8 Via`
ELEVATIONS
OF tum
DRAWN: DWO N0, REV %O'�S'�C pR*,OP•G\ \�
SCALE Dn1E2
L. 08-02310-r
8 s02E31 O
NT
S 07/24/14 2 OF 5
L.ROBERTOLOMAS•PE. Luis R. Lomas P.E.
1432INWOFORDRDLEWfSVILLE,,NC27D23 FL No.: 62514
434.688-0609 dbmas�lNomtispeaom
Ar
REVISIONS
REV DESCRIPTION DATE APPROVED
A REVISED INSTALLATION DETAILS 06/22/15 R.L.
B REVISED PER NEW REQUIREMENTS 01/10/18 R.L.
NOTES: 15. FOR ANCHORING FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM a
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ'PENIN I TT PROPERLY DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND 16. FOR ANCHORING FRAME INTO METAL STRUCTURE USE 14" SMS OR SELF DRILLING SCREWS
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING S THE WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
RESPONSIBILITY OF THE'ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
' 17. ALL FASTENERS TO BE CORROSION RESISTANT.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI,
FASTENED TO.MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER).
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 180A, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 19. WINDOW MAY BE INSTALLED HORIZO14TALLY OR VERTICALLY
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 20•GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTA14GULAR ASSEMBLY SHOWN
THE ARCHITECT OR ENGINEER OF RECORD. IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME,INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED ALUMINUM,6063—T6.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 3 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS .NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGNED:01/1812018
Art—
stPi®nEASusrenxxtERNLW LSU PLY \1111111
wulowesneAVIS
" 010432-2204v
SERIES 3000 ALUMINUM FLANGE FRAME 0 61
IMPACT FIXED WINDOW — HVHZ — PVB `
NOTES ��o''� 88TAT��OP_ ,i
TABLE OF CONTENTS DRAWN: Dwo NO. REV �4`*10R\OP G� I��
SHEET NO. NOTES DE ^aCRIPTION SCALE NTS D^TE 07/24/14 OB sOER 10 OF 5 B ,/77?OIVAL0\V��`
2 — 3 ELEVATION AND GLAZING DETAILS CROBERTOLOMASP.E Luis R. Lomas P.E.
1432WOODFORDRDLEWISWLLE,NO27023 FL No62514
4 — 5 INSTALLATION DETAILS 434.688.0609 dmmns@ldwutsW.eom