Loading...
HomeMy WebLinkAboutProduct Approval n�}r•.,�:"P,..,^.��rs1 {d ;z!�s` �cll V -'� 11:Z— ec; idjl L :ir� _d I O-t _37 BCIS Home I Log In I User Registration I Hot Topics ; Submit Surcharge I Stats&Facts I Publications f Contact Us f BCIS Site Map } Links ! Search Florida - r ProductApproval 1d USER:Public User Product Approval Menu>Product or ADolication Search>Application List>Application Detail FL# FL-17162-114 Application Type Editorial Change Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft.Myers,FL 33912 (800)432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature, James Flesher - jflesher@easternmetal.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation-&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/1.5.2/A440 2011 ASTM E1886 2005 ASTM E1996 2009 •TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/12/2018 Date Validated 06/14/2018 Date Pending FBC Approval Date Approved 06/19/2018 Summary of Products FL At Model,Number or Name Description 17162.1 Series 3000 Aluminum Impact Fixed Series 3000 Aluminum Impact Fixed Window with PVB Window with PVB interlayer interlayer. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17162 R4 C CAC NI012095-Rl.Ddf Approved for use outside HVHZ:Yes FL17162 R4 C CAC'NI012096-RI.Ddf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+85.0/-90.0 05/31/2024 Other:Maximum size of 120"x 48"at+70.0/-70.0 Installation Instructions Maximum size of 48"x 54"at+85.0/-90.0 GLASS FL17162 R4 II 08-02310B .Ddf INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R.Lomas,P.E.62514 FLORIDA BUILDING CODE ACCORDINGTO MIAMI-DADE FOR Created by Independent Third Party:Yes KURARAYINTERLAYERS Evaluation Reports - FL17162 R4 AE 513067B.Ddf Created by Independent Third Party:Yes 17162.2 Series 3000 Aluminum Impact Fixed Series 3000 Aluminum Impact Fixed Window with Sentryglas Window with Sentryglas interlayer interlayer Limits of Use Certification Agency'Certificate Approved for use in HVHZ:Yes FL17162 R4 C CAC NI012094.01-Rl.Ddf Approved'for use outside HVHZ:Yes FL17162 R4 C CAC NI012094-R2.Ddf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+100.0/-100.0 05/31/2024 Other:Insulated Impact Glazing Type A: +95.0/-100.0 Installation Instructions. Impact Only Glazing Type B: +100.0/-100.0 GLASS FL17162 R4 II 08-02309B .Ddf INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R.Lomas,P.E.62514 FLORIDA BUILDING-CODE ACCORDING TO MIAMI-DADE FOR Created by Independent Third Party:Yes KURARAY INTERLAYERS Evaluation Reports FL17162 R4 AE 513066B.Ddf Created by Independent Third Party:Yes 0 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement Accessibility Statement::Refund Statement - Under Florida law,email addresses are public records.If you do not want your e-mail address released in-response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails,provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please piovide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,ES.,please click here. Product Approval Accepts: n] Mialli EE M Credit Card Safe t�V 11r�-�V a v _MdA Safe NOTICE OF PRODUCT CERTIFICATION - O Acca 6' CERTIFICATION NO: N1012095-R1 DATE: 08/19/2014 MI CERTIFICATION PROGRAM: Structural COMPANY: Eastern IFNY, CODE: 1783=1 REVISION DATE: . 04/29/2018 To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the. product is active.and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has'been satisfied.A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAM if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"3000"Aluminum Flange Frame 16341 Domestic Avenue Fixed Window(Low Design Pressure) Ft.Myers,FL 33912 Configuration:O Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090" DuPont PVB Interlayer/3/16"Heat strengthened Glass or IG-3/16"Annealed Glass/Laminate-3/16"Heat Strengthened Glass/0.090"DuPont PVB Interlayer/3/16"Heat Strengthened Glass Frame: W-3048mm(120") H-1219mm(48") DLO: W-2984mm(117.5") H-1 181mm(46.5") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-11 Class CW-PG70 3048 g 1219(120 x 48)-FW AAMA 506-11 Design Pressure:3351 Pa(70 psf) ASTM E1886-05/E1996-09 Negative Design Pressure:3351 Pa(70 psf) TAS 201/202/203-94 Water Penetration Resistance Test Pressure:718 Pa(15.00 pst) Wind Zone 4-,Missile Level D Large Missile Impact Rated Product Tested By: Certified Testing Laboratories,Inc. Report No: CTLA 3010W-2/CTLA 3010W 2A CTLA 3010W-1/CTLA 3010W lA Expiration Date: May 31,2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel:(804)68475124 Fag: (804)684-5122 �■■■■■NOTICE OF PRODUCT CERTIFICATION �■■��" f,- c�RrrFic. q4�p4 CERTIFICATION NO: N1012096-R1 DATE: 08/19/2014 " 1 x . f CERTIFICATION PROGRAM: Structural COMPANY: . Eastern CODE:- 1783-1 REVISION DATE: 04/29/2018 To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certificationrepresents product conformity to the applicable specification and that certification criteria has been satisfied. ANAMI approved certification label mustbe applied to the product to claim certification status. Please review and advise NAMi if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"3000"Aluminum Flange Frame 1"6341 Domestic Avenue Fixed Window Ft.Myers,FL 33912 Configuration:o Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090" DuPont PVB Interlayer/3/16"Heat Strengthened Glass or IG-3/16"Annealed Glass/Laminate-3/16"Heat Strengthened Glass/0.090"DuPont PVB Interlayer/3/16"Heat strengthened Glass Frame: W-1219mm(48") H-1372mm(54") DLO: W-1181mm(46.5") H-13331nm(52.5") SPECIFICATION PRODUCT RATING AAN.[A/WDMA/CSA 101/I.S.2/A440-11 Class CW PG851219 x 1372(48 x 54)-FW AAMA 506-11 Design Pressure:4069 Pa(85 pst) ASTM E1886-05/E1996-09 Negative Design Pressure:4309 Pa(90 psi) TAS 201/202/203-94 Water Penetration Resistance Test Pressure:718 Pa(15.00 Pso Wind Zone 4-Missile Level D Large Missile Impact Rated Product Tested By: Certified Testing Laboratoriesi Inc. ReportNo: CTLA 3010W-3/CTLA 3010W-3A CTLA 3010W-1/CTLA 3010W-1A Expiration Date: May 31,2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE,INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 Fag:(804)684-5122 L. Roberto Lomas P.E. Engineering'Evaluation Report 1432 Woodford Rd. Lewisville,NC 27023 Report No.: 513067B 434-688-0609 rllomas@lrlomaspe.com Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. Ft.Myers,FL 33912 Product Line: Series 3000 Aluminum Flange Frame Impact Fixed Window—HVHZ-PVB Compliance: The above mentioned product has been evaluated for compliance with the requirements of the-Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document:drawing number 08-02310 Revision B,prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.:CTLA 3010W 2&-3 signed and sealed by Ramesh Patel P.E. Certified Testing Laboratories,Orlando,FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure,t70.0psf design pressure,15.Opsf water penetration(120"x48") +85.0/-90.Opsf design pressure, 15.0psf water penetration(48°x54°) TAS 203-94-Cyclic Pressure loading t70.0psf(120°x48°) I +85.0/-90.0psf(48°x54°) 3. Report No.:CTLA 301 OW-2A&-3A signed and sealed by Ramesh Patel P.E. Certified Testing Laboratories,Orlando,FL AAMAMDMA/CSA 101/I.S.2/A440-11 Design pressure: V0.0psf(120"x48") Water penetration resistance 15.Opsf +85.0/-90.Opsf(48°x54") "ASTM E1886-05 and ASTM E1996-09 ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 4 ASTM E1886/E1996 Cyclic Load Test,t70.0psf(120"x48°) +85.0/-90.Opsf(48"x54°) 4. Anchor calculations,report number 513067-1A,prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: Maximum design pressure: t70.0psf(120"x48°) +85.0/-90.Opsf(W.x54") • Maximum unit size: 120"x 48"and 48"x 54" • Units must be glazed per ASTM El 300-04/09,according to glazing details in approval drawing. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection In wind borne debris regions: • Frame material to be aluminum. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document 08-02310 Revision B. Certification of Independence: N��� S R•• t`� ��j/ Please note that I don't have nor will acquire a financial interest in any company ANN J`• manufacturing or distributing the product(s)for which this report is being issued.Also,1 � �• �►�C'E S� •� �_ don't have nor will acquire a financial interest in any other entity.involved in the approval 4-. TJ 0 51 • process of the listed product(s). * c • T 41= • �� ii��Fs 0RI .'c•COP G� �� O1VAL�����` 1 of 1 Luis R.Lomas,P.E. FL No.:62514 01/10/2018 REVISIONS 2" MIN. Tr EDGE DISTANCE REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/22/15 R.L. CONCRETE/MASONRY — 01/10/la R.L. BY OTHERS ?4•4 8 REVISED PER NEW REQUIREMENTS 1 1/4" MIN. I . I EMBEDMENT OPTIONAL IX BUCK4 1/4"1 MIN. SEE NOTES 3-7 SHEET I EMBEDMENT CONCRETE/MASONRY BY OTHERS APPROVED 1/4" MAX. 1/4" MAX. SHIM SPACE OPTIONAL 1X BUCK SEALANT SEE NOTES 3-7 SHEET I SHIM SPACE BEHIND FLANGE tr 1/4" TAPCON 1/4" TAPCON INTERIOR 2" MIN. EXTERIOR INTERIOR EDGE DISTANCE EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMS INSTALLATION DETAIL 1/4" TAPCON CONCRETEAMSONRYINSTALLATION APPROVED SEALANT NOTES: BEHIND FLANGE 1.INTERIOR AND EXTERIOR FINWEA BY OTHERA 1/4" MAX. NOT SHOWN FOR CLARITY. OPTIONAL lX BUCK SHIM SPACE 2.PERhVETERANDJOWTSEALANTSVOrlIERSTOSE SEE NOTES 3-7 SHEET 1 DESIONEPINACCORDANCEIN1THASIME2112 SIGNED.0111812018 CONCRETE/MASONRY En-stern eASTIMNINALSUMLY 0 4 4' 4, ===11 MO OCUMM BY OTHERS 4, W-7 ... "O'U"M 1 1/4" MIN. EMBEDMENT SERIES 3000 ALUMINUM, FLANGE FRAME 05j IMPACT FIXED WINDOW - HVHZ - PVB FLANGE INSTALLATION DETAILS TAT OF *.t4:= 0. Dwc;NO, Rev DRAWN: cl 2J.L. 08-02310 L z I MIN. —T EDGE DISTANCE S CALE NTS 1"AlE 07/24/14 5 OF 5 VERTICAL CROSS SECTION L ROBERTO ILOAt4S RISE Luis R. Lomas P.E. CONCRETEINASONRYINSTALLATION 1432 WOODFORD ROLMSVI"N027023 FL No.: 82514 +—} 5/8" MIN. REVISIONS EDGE DISTANCE5/8" MIN. REV DESCRIPTION DATE APPROVED WOOD FRAMING METAL EDGE DISTANCE A REVISED INSTALLATION DETAILS 06/22/15 R.L. OR 2X BUCK 1 7 16" MIN. STRUCTURE B REVISED PER NEW REQUIREMENTS 01/10/18 R.L. 8Y OTHERS EMBEDMENT BY OTHERS /4" MAX. NS SHIM SPACE 1/4" MAX. 5/8APPROVED 1/4MAX. APPROVED SHIM SPACESEALANT SHIM SPACE SEALANT EDGE INTERIOR BEHIND FLANGE BEHIND14" SMS OR �j14 WOODSELF DRILLING 14" SMS OSCREW SCREW SELF DRILLINSCREWMETASTRUCTURBY OTHEREXTERIOR APPROVED SEALANT BEHIND FLANGE INTERIOR EXTERIOR PvV INTERIOR JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION EXTERIOR 1 7/16" MIN. 1%4" MAX. EMBEDMENT ' SHIM SPACE 5/13" MIN. EDGE DISTANCE T - INTERIOR .I X14 WOOD r 14" SMS OR #14,WOOD SCREW SSELF CREW DRILLING SCREW / APPROVED APPROVED WOOD FRAMING -� EXTERIOR SEALANT 1/4'MAX SEALANT MAX. OR 2X BUCK �_ APPROVED SEALANT BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4 SHIM"SPACE BY OTHERS BEHIND FLANGE WOOD FRAMING METAL JAMB INSTALLATION DETAIL OR 2X BUCK 1 7/16" MIN STRUCTURE WOOD FRAMINGOR2XBUCKINSTALLAT/ON BY OTHERS BY OTHERS EMBEDMENT SIGNED:01/18/2018 5/8" MIN. EDGE DISTANCE r�►� y�e¢ g� °ASE ao of 5"R°' \111111I1I 5/8" MIN. ■ �6/a7La�i�'MO w,CI+NNETALSUwn ����\`` R LO/Y��i EDGE DISTANCE • VERTICAL CROSS SECTION "�A�,^w,. ^_r��"�t�� Fes* n +2 �J\S GEN VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR2XBUCK INSTALLATION SERIES 3000 ALUMINUM FLANGE FRAME 0 IMPACT FIXED-WINDOW — HVHZ — PVB �(, �1_ FLANGE INSTALLATION DETAILS TAT OF tv— NOTES: DRAWN: Dwa NO: aEV ��O'F•'cfpRtot. . s--ORV . NO1.�HOWNFORRIOR EITERIO FINISHES,BY OTHERS, SCA!E 11.17E 08502310 B 2.PERIMETER AND JOINT SEALANT BY07HERS TO BE NTS 07/24/14 4 OF 5 DESI(WEDINACCORDANCEWITH ASTME21f2 L.ROBERTO LOMAS AE Luis R. Lomas P.E. 1432 WOODFORD RD LEWISWLLE,NC27023 434.838-0609 rllomas@lAomasga.com FL No.: 62514 REVISIONS REV DESCRIPTION DATE APPROVED - 1 1/32" - 1 1/32" A REVISED INSTALLATION DETAILS 06/22/15 R.L. 3/16" ANN 3/16" IIS 3/16" TEMP 3/16" HS B REVISED PER NEW REQUIREMENTS 01/10/18 R.L. .090 PVB BY KURARAY .090 PVB BY KURARAY WEDGE GASKET316" HS WEDGE GASKET 3/16 HS 2541 BY MPI / 2541 BY MPI FPVC 65 DUROMETER DURASEAL FPVC 65 DUROMETER DURASEAL SPACER SYSTEM SPACER SYSTEM SEETING BLOCK (30096) BY OUANEX SEETING BLOCK (30096) BY OUANEX 85 DUROMETER STRUCTURAL SEALANT 85 DUROMETER STRUCTURAL SEALANT BY CENTRAL RUBBER SIKAFLEX 552 BY CENTRAL RUBBER SIKAFLEX 552 EXTRUSIONS EXTRUSIONS EXTERIOR INTERIOR EXTERIOR INTERIOR 3/4" BITE 3/4" BITE 77 GLAZING DETAIL A I GLAZING DETAIL A WHEN USED OUTSIDE THE HVH2 WHEN USED IN THE HVHZ 7/16•, 3/16" HS WEDGE GASKET .090 PVB BY KURARAY 2541 BY MPI 3/16" HS FPVC 65 DUROMETER SETTING BLOCK (30096) 85 DUROMETER STRUCTURAL BY CENTRAL RUBBER SEALANT EXTRUSIONS SIKAFLEX 552 EXTERIOR A 3/4" BITE INTERIOR GLAZING DETAIL B SIGNED.01/18/2018 gq ® AbrAM EASTERNARCIMCIMPALsstEALs ��►� ArdI�e ter/� ARNN EEMMSTANL SUPPLY \\�\S R• L077ji/ - - 16NI DWESTICAVE \\\J\ `eomx ,FLar�u `V�•\�CENS`� SERIES 3000 ALUMINUM FLANGE FRAME ;*�•/�1 aEE IMPACT FIXED WINDOW — HVHZ — PVB ^,o y([{I�riHc„�sL07�EE GLAZING DETAILS �7�. $TATEE OF J � L. /0NA 1 DWC No. 08-02310 RB SCALE NTS DATE 07/24/14 s"EET 3 OF 5 71�\\\� LROBERTOLOMASP.E. Luis R. Lomas P.E. 1432WOODFORDRDLEWISVILLE,,NC27023 FL No.: 62514 434.698-0509 r9omas@IAamaspe.com e REVISIONS 120" MAX FRAME WIDTH • REV DESCRIPTION DATE APPROVED 4" MAX A REVISED INSTALLATION DETAILS 06/22/15 R.L. 4" MAX 8 REVISED PER NEW REQUIREMENTS 01/10/18 R.L. 8" MAX 4" MAX 4' MAX 48" MAX FRAME WIDTH 6' MAX D.C. - 6" MAX 6" MAX 12" MAX O.C. 6" MAX 6" MAX —� /M 6" MAX 41 12' -� O.C. / 48" MAX / / 46 X FRAME / MAX HEIGHT D.L.O. 54" MAX 52 1 2 " / FRAME MAX HEIGHT D.L.O. 6" MAX 10 1/2" \ MAX O.C. 8,. -� �- 6" MAX MAX O.C. 4" MAX 4" MAX 6" MAX 4" MAX 4" MAX 46 1/2" MAX D.L.O. 117 1/2" D.L.O. DESIGN PRESSURE RATING IMPACT RATING ' DESIGN PRESSURE RATING IMPACT RATING LARGE SERIES 3000 PW FIXED WINDOW 185.0%90.OPSF MISSILE MPACT RGE f70,OPSF MISSILE/MPACT EXTERIOR VIEW MISSILE LEVEL D,WIND ZONE 4 AND HVHZ MISSILE LEVEL D,WIND ZONE 4 AND HVHZ SIGNED:01/18/2018 /9/EaAMMMOF ,' ster/ ASTER}ViAARWFAL LS1I1R14 R. l0 \imrlDawecAVQ rL31v vJ � ��. • S SERIES 3000 ALUMINUM FLANGE FRAME 0 61 IMPACT FIXED WINDOW - HVHZ - PV8 Via` ELEVATIONS OF tum DRAWN: DWO N0, REV %O'�S'�C pR*,OP•G\ \� SCALE Dn1E2 L. 08-02310-r 8 s02E31 O NT S 07/24/14 2 OF 5 L.ROBERTOLOMAS•PE. Luis R. Lomas P.E. 1432INWOFORDRDLEWfSVILLE,,NC27D23 FL No.: 62514 434.688-0609 dbmas�lNomtispeaom Ar REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/22/15 R.L. B REVISED PER NEW REQUIREMENTS 01/10/18 R.L. NOTES: 15. FOR ANCHORING FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM a REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ'PENIN I TT PROPERLY DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND 16. FOR ANCHORING FRAME INTO METAL STRUCTURE USE 14" SMS OR SELF DRILLING SCREWS TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING S THE WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR RESPONSIBILITY OF THE'ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. ' 17. ALL FASTENERS TO BE CORROSION RESISTANT. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI, FASTENED TO.MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 180A, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 19. WINDOW MAY BE INSTALLED HORIZO14TALLY OR VERTICALLY 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 20•GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTA14GULAR ASSEMBLY SHOWN THE ARCHITECT OR ENGINEER OF RECORD. IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME,INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM,6063—T6. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 3 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS .NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:01/1812018 Art— stPi®nEASusrenxxtERNLW LSU PLY \1111111 wulowesneAVIS " 010432-2204v SERIES 3000 ALUMINUM FLANGE FRAME 0 61 IMPACT FIXED WINDOW — HVHZ — PVB ` NOTES ��o''� 88TAT��OP_ ,i TABLE OF CONTENTS DRAWN: Dwo NO. REV �4`*10R\OP G� I�� SHEET NO. NOTES DE ^aCRIPTION SCALE NTS D^TE 07/24/14 OB sOER 10 OF 5 B ,/77?OIVAL0\V��` 2 — 3 ELEVATION AND GLAZING DETAILS CROBERTOLOMASP.E Luis R. Lomas P.E. 1432WOODFORDRDLEWISWLLE,NO27023 FL No62514 4 — 5 INSTALLATION DETAILS 434.688.0609 dmmns@ldwutsW.eom