HomeMy WebLinkAboutProduct Approval, Mullions unclippedMIAMI-
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
CGI Windows and Doors, Inc.
10100 NW 25" Street
Miami, FL 33172
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
T (786) 315-2590 F (786) 315-2599
.miamidade.�ov/econom
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Sentinel" Unclipped, Extruded Aluminum Tube Mullion -L.M.I.
APPROVAL DOCUMENT: Drawing No. M10-01, titled "Series Sentinel Unclipped Alum. Mullions",
sheets 1 through 7 of 7, dated 04/02/ 10, with revision D dated 11 /0 8/ 17, prepared by Al-Farooq Corporation,
signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp
with the Notice of Acceptance number and expiration date by the Miami —Dade County Product Control
Section,
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 144103.09 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
NOA No. 18-0117.01
Expiration Date: September 22, 2020
Approval Date: March O1, 2018
Page 1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
L Manufacturer's die drawings and sections.
(Submitted under NOA No.10-0510.14)
2. Drawing No M10-01, titled "Series Sentinel Unclipped Alum. Mullions", sheets 1
through 7 of 7, dated 04/02/ 10, with revision C dated 02/25/ 15, prepared by Al-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
along with marked -up drawings and installation diagram of an aluminum tube mullion,
prepared by Hurricane test Laboratory, LLC, Test Report No. HTL-0080-030341,
dated 03/24/11, signed and sealed by Vinu J. Abraham, P.E.
(Submitted under NOA No.114330.22)
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
ith marked -up drawings and installation diagram of an aluminum tube mullion
along w,
prepared by Hurricane test Laboratory, LLC, Test Report No. HTL-0080-030140,
dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E.
(Submitted under NOA No. 10-0510.14)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 5th
Edition (2014), dated 09/23/14, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
Manuel Pe z, P.E.
Product Control E finer
NOA No. 18-0117.01
Expiration Date: September 22, 2020
Approval Date: March 01, 2018
E-1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 5th Edition (2014), and of no
financial interest, dated October 4, 2014, issued by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
2. Laboratory compliance letter for Test Report No. HTL-0080-03034I, issued by
Hurricane Test Laboratory, LLC, dated March 24, 2011, signed and sealed by Vinu J.
Abraham, POE*
(Submitted under NOA No. 11-0330.22)
3. Laboratory compliance letter for Test Report No. HTL-0080-030140, issued by
Hurricane Test Laboratory, LLC, dated March 3 0, 2010, signed and sealed by Vinu J.
Abraham, P.E.
(Submitted under NOA No. I &0510.14)
4. Proposal No. 094942 issued by BCCO, dated November 05, 2009, signed by Manuel
Perez, P.E.
(Submitted under NOA No.I &0510.14)
Product Control ,x finer
NOA No. 18-0117.01
Expiration Date: September 229 2020
Approval Date: March O17 2018
E-2
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No M10-01, titled "Series Sentinel Unclipped Alum. Mullions", sheets 1
through 7 of 7, dated 04/02/10, with revision D dated 11/08/17, prepared by Al-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E.
1. None
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with EBC 6tn
Edition (2017), dated 10/15/14 and updated on 09/25/17, prepared by Al-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 3 Edition (2014), with FBC 0
Edition (2017), and of no financial interest, dated September 28, 2017, issued by Al-
Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
G. OTHERS
1. Notice of Acceptance No. 14-1103.09, issued to CGI Windows &Doors for their
Series "Sentinel" Unclipped, Extruded Aluminum Tube Mullion - L.M.I. approved on
03/05/15 and expiring on 09/22/20.
Manuel Perez P.E.
Product Control Examine
NOA No. 18-0117:01
Expiration Date: September 229 2020
Approval Date: March O17 2018
E-3