Loading...
HomeMy WebLinkAboutProduct Approval (3) 2/14/2019 Florida Building Code Online o BOL BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications Contact Us I BCIS Site Map I Links I Search b a °9 Product Approval + j - USER:Public User RECEIVE[ Product Approval Menu>Product or Application Search>Agplic on List> pplicatlon Detail • FL# FL15210-R6 AUG O 9 :'q Application Type Revisio Code Version . aT• Wde CounEy, porrTliktinct , Application Status Approved Comments Archived Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com - Quality Assurance Representative Ron O'Connell Uj Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com it Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J. King, P.E. J Validation Checklist-Hardcopy Received Certificate of Independence FL15210 R6 COI (a)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 -ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ1QRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHldA%3d%3d 1/4 2/14/2019 Florida Building Code Online G 155 2005 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15210 R6 Equiv(a) Equivalency of Standards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2017 Date Validated 09/18/2017 Date Pending FBC Approval 09/20/2017 Date Approved 12/12/2017 Sum Products L#, Model,Number or Name Description 15210.1 a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration) Fiberglass Door its of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b) Inst 15210.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.1 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.1.p!Lf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. - -15210.2 . b...Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door.with Sidelite or-- Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.2 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.2.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.3 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.3.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door-Inswing/Outswing Grain/Rustic/Mahogany Series O (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.4 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.4.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.5 e. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO-Configurations) Fiberglass Door https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv3yVVKJZ1QRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHldA%3d%3d 2/4 2/14/2019 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.5 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.5.pdf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 15210.6 f. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.6 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.6.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.7 g.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing (X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FLIS210 R6 II (b) Inst 15210.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.7 for Design Pressure Ratings,any FLIS210 R6 AE (b) Eval 15210.7.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.8 h.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites-Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:.Yes- - - `Created,by Independent Third Party:,Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.8 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15210.9 1.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.9 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.9.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.10 j.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing (X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.10 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.10.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.11 k.Smooth Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites-Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FLIS210 R6 II (b)Inst 15210.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.11 for Design Pressure Ratings,any https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHldA%3d%3d 3/4 2/14/2019 Florida Building Code Online additional use limitations,installation instructions and product FL15210 R6 AE (b) Eval 15210.11.pdf particulars. Created by Independent Third Party:Yes 15210.12 I. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Outswing(XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, RE.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.12 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, 15210.13 m. Smooth/Wood Grain/White Wood B'0"Impact"Opaque Fiberglass Single Door with Surface Bolts Grain/Rustic/Mahogany Series 0 -Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b) Inst 15210.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.13 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.13.pdf additional use limitations, installation instructions and product. Created by Independent Third Party: Yes particulars. 15210.14 n.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface Bolts Grain/Rustic/Mahogany Series O on Active Door panel-Outswing (XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.14 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.14.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. "1521b.15 o.Srrtboth/Wood Grain/White Wood 80"Impact"Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series O WINDSERTTm an operational window insert-Outswing(X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.15 for Design Pressure Ratings,any FL15210 R6 AE (b) Eval 15210.15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy atement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 45S,F.S.,please click here. Product Approval Accepts: MW PIZ-70 ® 99 O Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHldA%3d%3d 4/4 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product / Report I I l August / 2017 Product Category Sub Category Manufacturer Product Name Exterior Swinging Plastpro,Inc. Smooth I Wood Grain I White Wood Grain Exterior Door 5200 W.Century Blvd. Rustic 1 Mahogany Doors Assemblies Los Angeles,CA 90045 Series O Fiberglass Door Phone 440.969.9773 Inswing/Outswing-"Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt, P.E. (System ID#1998)for Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with FBC Sections 1609.1.2& R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defiQe0in ASTM.E 1996 and FBC 5ections.1609.1.2.2,& 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.1 require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for"HVHZ". All other configurations do not meet the water infiltration requirements for the"HVHZ"and must be installed only in non-habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 8. See drawing FL-15210.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01390365 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. Lyndon F.Schmidt,P.E. TEL 01391846 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. William Shelton,P.E. ETC-05-255-16776.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Joseph L.Doldan,P.E. ASTM G 26-95 ETC-06-255-17412.0 ASTM E 84-05 ETC Laboratories Joseph L.Doldan,P.E. ETC-07-209-19303.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Ben Meunier 2. Drawing No. Prepared by Signed&Sealed by No.FL-15210.1 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 3. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Quality Assurance ♦aEe���e¢eoee���o�� Certificate of Participation issued by National Accreditation and Management ♦♦ ♦ �•S�Hi' I� C . ... O Institute,certifying that Plastpro,Inc.is manufacturing products within a quality e,♦0 �. G .N S; I s�AA assurance program that complies with ISO/IEC 17020 and Guide 53. `e ;•t,� C.' ,oma No 43409 _0 STATE OF = � vo04 , P <�4 Lyndon F.Schmidt,P.E. em O F' FL PE No.43409 8/31/2017 Sheet 1 of 1 s`��so0/ �o y �0♦ lastpro 5200 W. CENTURY BLVD. Z 5yz 5 ;Z ' % 6 U LOS ANGELES CA 900450 J>° ANGELES, i / \\\ N Ml I4r rrrr�s1*P 8% zomo 37.50"MAX.OVERALL oro z Smooth / Wood Grain / White Wood Grain I-- FRAME WIDTH �1 "" Rustic /Mahogany ` e Emo o m oµ Q o o a Series O Fiberglass Door < LL o INSWING/OUTSWING ® ® r? �w "IMPACT" �o GENERAL NOTES O z "�z z o� 1. This product hos been evaluated and is in compliance with the 6th Edition(2017)Florida Building 12 zo z�w Code (FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). O J a 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base w C3 N 6 material shall be beyond wall dressing or stucco. w w a m j 0 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and v ? o w does not require an impact resistant covering. ^ a a a 0 4. When used in areas outside of the"HVHT'requiring wind bome debris protection,this product > m V, complies with FBC Sections 1609.1.2&R3012.12 and does not require an impact resistant covering. O O E This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC N ih o V a Sections 1609.1.2.2&R3012.1.2.1. m `` 5. For 2x stud construction,anchoring of these units shall be the some as that shown for 2x buck masonry N N construction. d d z ww O 6. Site conditions that deviate from the details of this draw ng require further engineering analysis by a z �' licensed engineer or registered architect. Q Q 7. Outswing configurations meet water infiltration requirements for"HVHT'.All other configurations do ~ not meet the water infiltration requirements for the"HVHZ"and must be installed only in non-habitable a a 6 t; areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. ^w g TABLE OF CONTENTS SHEET# DESCRIPTION SHEET# DESCRIPTION t m 1 Typical Elevations,Design Pressures&General Notes 7 Horizontal&Vertical Cross Sections(Direct to Masonry) Eee MAX DESIGN_PRESSURE(PSFJ "'z E3 2 Door Panel Details B 3-point lock details TfON FRAME DATE:02 16/12 °z w 3 Horizontal&Vertical Cross Sections(2X Buck) 9 3-point lock details __ _.D1N1ENSfON _< POSITIVE NEG 9711/E N.T.S. 4 Horizontal&Vertical Cross Sections(1 X Buck) 10 Buck and frame anchoring DWG.W. JK m' s 5 Horizontal&Vertical Cross Sections(Direct to Masonry) 11 Components 37.5"x 82.0" +75.0 -75.0 chic ar: LFS 3 # 6 Vertical Cross Sections(Thresholds) 12 Bill of materials DRAWNG NO- n r ardware designpressure limitations FL-15210.1 y CI sHEEr1 of 12 d i fi fill ............ OX Ze 0.4" EXTERIOR I —F— -- R z * z Y-. ZO nN o ZO 0 O a -z K 0 INTERIOR TOP RAIL 0 mo w CAP(pvq STILE(LVL) ci 0(L "a HINGE STILE(LVL) CAP(PVC) (COMP.) 5 LZ C 6 -z HORIZONTAL CROSS SECTION 11 0 --T hi 2 r.. to cc 35.75'MAX O.A. WIDTH C30 EL C) O0 0 ..........=.- u ......... .. .... ......... ................................ ..................... ............I� .................. .......... ..............L. ........... RDWAPF-TABLE' .............�;.... ......................... w ............................................................................................................ INTERIOR EXTERIOR .............. ............z........mm...,.- I0 ...-.M*.,..:............ . ......... ................... .........:.._ ... .. .. PR Fj 44 MA KWIKSET KNOB: SIGNATURE SERIES DEADBOLT. SIGNATURE SERIES(980) 75 FOAM CORE (PgLYUREMANE- d KNOB: 7 SERIES(F51) 13 PCF MIN.) N Xu I SCHLAGE ±75 N DEADBOLT. "a"SERIES(060/62) V) X T Z9 c'! SEE HARDWARE TABLE PAMEX LEVER: FL35SEIUES Q) 75 �j DEADBOLT: FD7 SERIES MULTIPO o HOPPE INT LOCK: HLS9000 3-POINT TONGUE ±50 FIBERGLASS SKIN SEE HARDWARE TABLE (0.125-MIN.THK.) (L IL ENDURA MULTIPOINT LOCK: TRILENNIUM 3000(3-PT) ±75 fe Lj See sheets 5 and 6 for multipoint lock details.` C c, BOTTOM RAIL 0 (COMP.) a^z 2 DAm 02116112 12, N.T.S. 40 DOOR PANEL DWG.BY: JK Plastpro Fiberglass VERTICAL CROSS SECTION CHK Irf. LFS DRAWINr NO- FL-15210.1 SHM_I---L2 R:\Cllents\Plasti:6,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\PL-15210.1-6.dwg,3.1 m vZ m S� r —n --—0 ti to y a V v r0n O N A o.N v ® Q® ® AW m M 0 Q VA VN t7fN AN WN 0 ;Urn o V(n V y N r V a 0 o D r rprn O N o rn m m n O w Z �A Z m •v WW d..o O a < " cap �r o N cn Q /. •� V av 0.15"C-SINK n r (TYPJ 1���� ;SCNI�J/��4i� � u Cft;4 1-1/4"MIN. ? L EMB.(TYP.) L}� NO.43409 9 G`r7�•o. r' g PRODUCT: Documents Prepared By: ��,,��• � PLASTPRO INC. Lyndon F. Schmidt ��i�t�•• 0�•'�G`;��� li I cN FIBERGLASS DOOR P.E. No. 43409 TONAL @ ;, Z -., 1111111 •o" N ti 2 7 24 17 UPDAIE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: (Qp BUILDING CONSULTANTS, INC. Ip x in 1 3 9 15 UPDATE TO 51H ED. 2014 FBC JK rJL1/f�P.O. Box 230, Voirico, FL 33595 N - N NO DATE BY CROSS 3EC ONTALNS (2XnBUCK) uY Phone No.: 813.659.9197 REVISIONS FBPE CA. No. 9813 ®2016 R.W.BUILDING CONSULTANTO INC. R:\Cllents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Flherglass-Impact Opaque and GlazeAC-Drawings\FL-15210(2017)16-15210.1-6.dwg,4.1 V M a a.m' t:14 a n. a 0s x 0C) For n 0 X a • �g� S. to �4 o y O N z A_ 22 0 0 a 0 A N Or V 13 N to O 4 O A,y Z a Z a m M �c1 rn 22 o g a A W 70 .vv A n pp Y'o ° e• ` 63 ^ o Z m IO ,. ,v N n `111 111111!!!' 1 !� 1-1/4'"MIN. ` :SCHM�.. EMB.(TYP.) f ' c x $ PRODUCT: Dovumente Prepared By. y PLASTPRO INC. Lyndon F. Schmidt ii� R...... Al :S I� N FlBERGlASS DOOR P.E. No. 43409 �s;ONAL11G�1�1� 0 r- "-Zi rn 2 7 24 17 UPDATE 70 6TH ED. 2017 FBC JK PART OR ASSEMBLY: �QR��BUILDING CONSULTANTS, INC. fn\ 1 3 9 15 UPDATE TO 5TH E0. 2014 FBC JK -I/I/ P.O. Box 230, Valrico, FL 33595 IN N NO DATE BY HORIZONTAL & VERTICAL VVY phone No.: 813.659.9197 REVISIONS CROSS SECTIONS (1X BUCK) FBPE CA No. 9813 ® 2015 R.W.BV ILDING CCNG-NTE INC. R:\Cllents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,5.1 � v M y "G G e u N Oo x �N t'o S7, Sm boa 3z ,� o fpm N y V m O c ' Z y� z IA l0 os x y�o O ?. N V tV o�g �Or mJ N =oA w-N V n y 3 ^+ Z �n m rn n M a os T o m y o st0r .�0O o yip N D n V d. 3 1 ' o Z z I� a EMB. P. � .................. N ••.1' o.43408 all PRODUCT: Ooeument.Prepared Syr FPLASTPRO INC. Lyndon F. Schmidt ��i�`S''• ORION.�'0``��` I� j z N FIBERGLASS DOOR P.E. No. 43409 j/11, fill"' 0 2 7724/17 UPOA7E 70 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. p in 1 3/9/15 UPDATE TO 5TH ED. 2014 HBC JK P.O. Box 230, Valrico, FL 33595 Iv NO DATE gy HORIZONTAL & VERTICAL CROSS vv Phone No.: 813.659.9197 REVISIONS SEC17ONS DIRECT TO MASONRY) FBPE CA No. 9813 0 2016 R.W.13V ILOINO CONS-8 INC. R:\OienLs\Plastpm,Inc PERMANENT\A•Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-1S210.I-6.dwg,6.1 ° •'d O r 0. 0 r =n 00 0 y T n . CD m O Q W � . w W W ° v iia M 4 O M O 2 o p . a r- vn PC0 o a� Z ek A O A O• � M 1-1/4°MIN. EMB.(TYP.( M A Q n ° O 0 �O IT D z o' .. m •° z w w w O ``,putur►Nri No.43409 PRODUCT: Document.Prepared By: PLASTPRO INC. Lyndon F. Sehmldt ��i�•(�_• Q�''Q ��� FIBERGLASS DOOR P.E. No, 43409 ''y77jJ,�pNALt \��� o N" r y 2 7 24 17 UPDATE 70 6TH ED. 2017 FSC JK PART OR ASSEMBLY: @ BUILDING CONSULTANTS, INC. 5, ,Ol 1 3 9 15 UPDATE 70 STH ED. 2014 F&C JK J�. P.O. Box 230, ValNco, Fl-33595 IN w NO DATE gY VERTICAL CROSS phone No.: 813.659.9197 REVISIONS SECTIONS (THRESHOLDS) FBPE C.A. No. 9813 0 201 6 R.W.BUILD-CONSULTANTS IND. MAX. MAX. ,. , eco 1.25' E �� •� 1S" E MIN. MIN: MAX Nt Z 4,r O' V,; c m ro p /i� '•........ .,.-�}: .•h 4:J }: '�--4, ::�3:� ,� 1 ll a N m Z m u� d p oa 40 o a vZ EXTERIOR INTERIOR EXTERIOR INTERIOR F � 8o 5 VERTICAL CROSS SECTION e6 VERTICAL CROSS SECTION o "¢ 7 Shown Direct 10 Mosonry 7 Shown Direct to Masonry Zo 0 Outswing only w/4.9116'Jamb Outswing only w/6 9/16'jamb r- 0rn m EL Ny m r Ci � KZ 0 =� U C C 0Q INTERIOR ::E \2! .; N N m 40 40 >°.f 2 v, INTERIOR rn H IN am 40 MKA ..,.. u D O M "� D a1j I. V O ELD 1-1/4"MIN. EMB.VYP.) ^^ m a i�i�i w z ' E D EXTERIOR i I EXTERIOR to I 1-114"MIN. 1-1/4°MIN. M 1-1/4°MIN. wte 02/16/12 i �^r EMB.(TYP.) EMB.(TYP.) B ) scr a N.T.S. s 1 HORIZONTAL CROSS SECTION �FIORIZONTAL CROSS SECTION SECTION 4 HORIZONTAL CROSS SECTION oma- 11c 2 HORIZONTAL CROSS SECTION 7 Shown Direct to Mason cwc.aro LFS 3 Shown Direct to Mason 7 Shown Direct to Masonry 7 Shown Direct to Mason 7 Outswing only w/6-9/16'jamb oaavnNc wo.: u Outswing only w/4-9/16'jan Outswing only w/4-9116'jamb Outswing only w/6 9/16'jamb N FL-15210.1 a ;xUr 7 OF 12 0 a R:\Olerds\Plastpro,Inc PERMANENT A-Florida Product Approvak\FL-15210 HVHZ Fiberglass-Impact Opaque and Giazed\C-Dnrwings\FL-15210(2017)\FL-15210.1-6.dwg,8.1 Z c > OVERALL HEIGHT M HANDLE HEIGHT rn ri 0 e^o°g• c a rn M fn 10.04" rn c 1 N y � �o F 4.63" N O_ I~3.63" X0.11" xx b i C Orzz O O r^ I o st � 00 o� oX o ;s m � � x m 3 m a ® ID 0.1" m v s C) m 0c W m On 0 0 -c O ``` I��O''', 43.09" `. SCN . • No.43409 o Q PRODUCT: OoeumenU Proparod W. �� A PLASTPRO INC. Lyndon F. Schmidt , �ZOR.....Q �� I00 l R \ FIBERGLASS DOOR P.E. No. 43409 ''�SS�O►yA4t�\��� 2 -772-471-7 UPDATE TO 6TH I.D. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. Ip to 1 319115 UPDATE TO 5TH ED. 2014 FBC JK 3—POINT LOCK DETAILS P.O. Box 230,Voldco, FL 33595 ry K) NO DATE BY Phone No.: 813.859.9197 REVISIONS FSPE C.A. No. 9813 ®201 2 R.W.BUILCINra CONSULTANTS INC. R:\Cllents\Plastpro,Inc PERMANE"-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,9.1 } Z C W� O Z n z 3 N Z O n 0 3 G) Go 0 a pm 3 rp v 24.25' 23.0" 15.0" ``%0111111111j1j �.X ` No.43409 Tn-G� * •*r §� $ PRODUCT: Document.Prepared By. PLASTPRO INC. Lyndon F. Schmidt '�i�s''• ...... FIBERGLASS DOOR P.E. No. 43409 �islONAL1 ��� N y 2 7 24 17 UPDATE TO 6TH FA. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. Io h 1 319115 UPDATE TO 5TH ED. 2014 FRC JK 3—POINT LOCK DETAILS P.O. Box 230, Valrico• FL 33595 N N NO DATE BY Phone No.: 813.559.9197 REVISIONS FBPE C.A. No. 9813 2012 R.W.BUILDING CONG-NTS INC. 4- 4-9/16"jAMB�pDIRECT TO MASONRY JAMB(TYP.) 4" 49/16"JAMB P (SEE SHEET 71 %% A, a (TYP.) _' o.J�O M �I �.�y �m z 4°:�O� i��4'rrrr*ptt``` o d mo. SEE HINGE L 2X BUCK ` z D TYP.HEAD �, DETAIL(TYP.) &JAMBS G 1X BUCK (� S o z o 9 m$w o -V o DEL r 7 DIRECT TO o Y a ul" m d a m MASONRY a MASONRY D MASONRY n p o OPENING OPENING m EYP.HEAD E o z &JAMBS FRAME z a � ( 0 i N ti zo z d 2X BUCK 49/18'JAMB M _ o Q W 2X-BUCK 6-911 G'JAMB N R ED ME e o DIRECT TO N m MASONRY r a� JAMB(TYP.) n o r (SEE SHEET 7) C, Ia m a ILI o a ADASILL >>m ONLY 4 i BUCKANCHORING STRIKEJAMB FRAME ANCHORING �fRINGE:JAMB w P, o Masonry construction oo n CONCRETE ANCHOR NOTES: : DIRECTTO a 'E I.Concrete onchorlocations at the comers maybe arfusted to maintain the min. DIRECT TO MASONRY M DIRECT TO edge distance to mortarjoints. MASONRY M >j 2.Concrete anchor locations noted as MAX.ONCFMER'must beadjusfedto M MASONRY i maintain the min.edge distance to modarjoints,additional concrete anchors 1X BUCK G maybe required to ensure the MAX ON CENTER'dimerdon are not exceeded 28 G 1 X BUCK 9 1 X BUCK GtV A 3 Concrete anchor table 2X BUCK L a -MIN_CLEARANCE MIN.CLEARANCE 2X BUCK 58 58 2X BUCK 2X BUCK Ln m A` - OR AN Ok MIN11 pp S,. EMBEDMENT -TO MASONRY TOANCHOEM r• a 1XBUCK 11 DIRECT TO 12 i TAPCON /P 1-1/4 2 4" M MASONRY 1D DIRECTTO 11 ❑ sr",c. N.T.S. EL ® 1 4 1.114" t4" MASONRY G 1XBUCK M.BY.. JKULTRACON /s Irn 27 2X BUCK cRK BY:3/16" 1.1/4" AS SHOWN 1.1/2"TAPCON DRAWING ND.: WOOD SCREW INSTALLATION NOTES: H&DEADBOLTDETAIL HINGE DETAIL FL-15210.1Maintain a minimum 51W edge dstance,l"end distance,&1"o.c.spacing of Inswing n wood screws to prevent the spGHing of wood. sNEEr 10 of 12 0 z R.X01entAPIastpr0,Inc PERMANENTV�-Florida Product ApprovalskFL-15210 HVHZ Flberglaw-Impact Opaque and GlazedXC-DravAngs\FL-15210(2017)\FL-15210.1-S.dwg,11.1 L Uff 00 00 Z!0 0Oz = ZC .2B' -.98" 1.75 0 Z no 00 0 P Z' N 0.65" 1.25' aA A0 it - to 0.937, 0 0 0.75' 0 LZ ,4 Ti, 9, No.43409 % PRODUCT: D..—t.Prepared Sr.-1 V, W. rn F, PLASTPRO INC. Ly.d.n F. ldt ............ FIBERGLASS DOOR P.E. No. 43409 —o 2 -7T24-T17--UPDATE TO 6TH ED. 2017FEC PART OR ASSEMBLY- BUILDING CONSULTANTS, INC. Ip in 1 319115 UPDATE TO 5TH ED. (2014) FEC JK eJl. P.O. Box 230, Valrico, FL 33595 N IV NO DATE BY Phone No.; 813.659.9197 REVISIONS — COMPONENTS FSPE C.A. No. 9813 (0 2012 R.W.BUILDIND CDNSULTANTS INC. . ```�J``�L •'K ' i'i'i . ............ �i BILL OF MATERIALSX.O DE o DESCRIPIION tlA1ER1A[. o .0*TY,( J�ci A 1X BUCK SG>=0.55 WOOD N B 2X BUCK SG>=0.55 WOOD `vim:, ;k• ' o C 114"MAX.SHIM SPACE D 1/4"X 23/4"PFH ELCO OR ITW CONCRETE SCREW STEEL ,1�71rI Itf``�•` o«ai m E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE e, �+•: 301 OR HOLLOW BLOCK CONFORMING TO ASIM C90 r 9 p o o= G 3/16"x3-1/4"PFHITW CONCRETE SCREW STEEL �\ y E� oaa� 1 1I4"X 1 3/4"PFH ELCO OR Tf W CONCRETE SCREW STEEL a vnt m a a p J 1/4"X33/4"PFH ELCO OR ITW CONCRETE SCREW STEEL a k K 114'X 2-114"ITW CONCRETE SCREW STEEL L #10 X 2-1/2"PFH WOOD SCREW(1.15"MIN.EMBEDMENT} STEEL M 3/16"X 2-1/4"ITW CONCRETE SCREW STEEL N 3/16-X 2314"ITW CONCRETE SCREW STEEL P 114"X 2-114"PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP./VINYL 2 FINGER JOINTED PINE FRAME WOODo 7 WEATHERSTRIP FOAM 9S j 0 8 DOOR BOTTOM SWEEP VINYL m 9 4'X 4"BUTT HINGE STEEL o 11 #9 X 3/4"PFH WOOD SCREW STEEL m �; 22 3 PO1NT'7ONGUE"MULTIPOINT LOCKSET(Mfg.BY HOPPE) STEEL 23 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM} STEEL o 25 LATCH AND DEADBOLTSTRIKE PLATE(TONGUE SYSTEM} STEEL a 0 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL �m 29 ADA THRESHOLD ALUM v o 30 OUTSWING THRESHOLD ALUM/WOOD 31 OUTSWING THRESHOLD ALUM/WOOD 32 OUTSWING THRESHOLD ALUM/WOOD M N 33 OUTSWING THRESHOLD ALUM/COMP o z 34 OUTSWING THRESHOLD ALUM/WOOD ` 36 INSWING THRESHOLDALUM/COMPLn 37 INSWINGTHRESHOLD ALUM/WOOD oo 38 INSWING THRESHOLD ALUM/COMP, S 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS j 55 #10 X 1-1/2"PFH SCREW STEEL Z s 57 TACKING-PLATE STEEL ^�_ 58 #8 X 2"PFH WS STEEL v„r a 60 MULTIPOINT STRIKE PLATE STEEL ro a a b2 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL N t Z o DA Q2/16/12 = s N.T.S. ° mm By, JK cHH.rn: LFS 3 ORAWWO NO.- FL-1.52 10.1 O.:FL-15210.1 " 0 v SHEET 12 OF 12