HomeMy WebLinkAboutProduct Approval Florida Building Code Online 8/9/19,1:01 PM
• + e
4ab �f
BCIS Home Log In , User Registration Hot Topics Submit Surcharge Stats&Facts Publications f Contact Us BCIS Site Map Links Search
da
=T Product Approval
USER:Public User
� qac ss
Product Approval Menu>Product or Application Search>Application List>Application Detail
RECEIVE®
FL# FL11651-R3
Application Type Revision AUG 0 9 2019
Code Version 2017
Application Status Approved ST. Lucie County,Permitting
Comments
Archived 0i
Product Manufacturer Gulf Coast Supply&Manufacturing, LLC.
Address/Phone/Email 4020 S.W.449th Street
Horseshoe Beach, FL 32648 I y
(352)498-0778 1
info@gulfcoastsupply.com
Authorized Signature Eng David REVIEWED FOR
info@gulfcoastsupply.coe®DE COMPLIANCE
Technical Representative David Eng re , ILUC5E COUNTY
Address/Phone/Email 14429 SW 2nd PI B(OCC
Ste G30
Newberry, FL 32669
(352)498-0778
info@gulfcoastsupply.com File Quality Assurance Representative David Eng g'ile Copy
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
`! Evaluation Report- Hardcopy Received
Florida Engineer orArchitect Name who developed Daniel S. Kuhn
the Evaluation Report
,-Florida License PE-75519
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
1 r Validation Checklist-Hardcopy Received
Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.pdf
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 1 of 6
Florida Buhding Code Online 8/9/19,1:01 PM
11651.10 24 Ga. Gulf Seam Min 24 Ga.Gulf Seam 16"Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R3 II FL11651 10 R3 Metal Roof PanelDetail-
Approved for use outside HVHZ:Yes s�gned.{�df
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-93.5PSF Created by Independent Third Party:Yes
Other:-93.5 psf @ 18"o.c.Install per manufacturers details. Evaluation Reports
Not for use in HVHZ Zones. FL11651 R3 AE FL11651 1010 R3 24GulfSeam 16 1x4 5-
32 I ood NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.11 24 Ga.Gulf Seam Min 24 Ga.Gulf Seam, 13/4"Snap Lock, 18"Wide Roof Panel
over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R3 II EL11651 11 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes9ned.�df
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-69.25 psf @ 24"o.c.clip spacing. -108.5 psf @ 12" Evaluation Reports
o.c.clip spacing. Install per manufacturers details. Not for use FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
in HVHZ Zones. 32�ood NonHVHZ-signed.odf
Created by Independent Third Party:Yes
11651.12 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes Sian A pff
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-156.5PSF Created by Independent Third Party:Yes
Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports
6"o.c.fastener spacing.Install per manufacturers details. For FL11651 R3 AE FL11651 12 R3 265vCrimp15-
use in HVHZ Zones. 32PlywoodHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R3 11 FL11651 13 R3 MetalRoof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-131.PSF Created by Independent Third Party:Yes
Other:-94.25 psf @ 16"o.c.fastener pattern.-131.0 psf @ Evaluation Reports
16"o.c.fastener pattern.Install per manufacturers details. FL11651 R3 AE FL11651 13-113-265vCrimo IS-
Not
SNot for use in HVHZ Zones. 32Plywood NonHVHZ-signed.odf
Created by Independent Third Party: Yes
11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 14.R3 Mg-t&1 Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF Created by Independent Third Party:Yes
Other: -108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports
6"o.c.fastener spacing.Install per manufacturers details. For FL11651 R3 AE FL11651 14 R3 265vCrimo 1x4 15-
use in HVHZ Zones. 32Plvwoo onHVHZ-signed pdf
Created by Independent Third Party:Yes
11651.15 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 15-113 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-161.OPSF Created by Independent Third Party:Yes
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports
psf @ 5 3/16"spacing.-161.0 psf @ 5 3/16"o.c.fastener FL_ 11651 R3 AE FL11651 15 R3 26GulfLok 16 IS-
spacing.Install per manufacturers details. For use in HVHZ 32Plywood HVHZ-sianed.pdf
Zones. Created by Independent Third Party: Yes
p://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 4 of 6
4
Florida Building Code Online 8/9/19,1:01 PM
11651.4 1"24ga.VersaLoc 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes F1.11651 R3 II EL11651 4 113-Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes ,Agned.of
Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-138.5PSF Created by Independent Third Party:Yes
Other:-71 psf @ 24"o.c.clip spacing.-138.5 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details. For use in EL11651 R3 AE FL11651 4 R3 4Versal-oc SR 16.5 15-
HVHZ Zones. 32Plvwood HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.5 1"VersaLoc.032"Aluminum 1"VersaLoc min .032"Aluminum over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.Rdf
Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-101.0PSF Created by Independent Third Party:Yes
Other:-63.3 psf @ 24"o.c.clip spacing. -101.0 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details. For use in FL11651 R3 AE FL11651 5 R3 lin 032Versal-oc
HVHZ Zones. SR 16 5-32PlvwoodHVHZ-signed.p-df
Created by Independent Third Party:Yes
11651.6 1.5"24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sj_ ng ed odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF Created by Independent Third Party:Yes
Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports
o.c.clip spacing.-116.0 psf @ 6"o.c.clip spacing.Install per FL11651 R33 AE FL11651 6 R3 1.5 24GulfSnaR 16 15-
manufacturers detals.For use in HVHZ Zones. 32PlvwoodHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.7 1.5"24ga.VersaLoc 1.5"VersaLoc min 24ga. 16"wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detafl-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-123.5PSF Created by Independent Third Party:Yes
Other:-59.75 psf @ 24"o.c.clip spacing.-123.5 psf @ 12" Evaluation Reports
o.c.clip spacing. Install per manufacturers details. For use in FL11651 R3 AE FL11651 7 R3 1.5 4VersaLoc 16 15-
HVHZ Zones. 32Plywood HVHZ-signed Rif
Created by Independent Third Party:Yes
11651.8 ]2"24ga. MegaLoc Min 24 Ga.2"MegaLoc 18"wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II EL11651 8 R3 Mg_W oo
Approved for use outside HVHZ:Yes signed_pdf �-g--f Panel Detail-
Approved
Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-71.0 psf @ 24"o.c. clip spacing.-108.5 psf @ 12" Evaluation Reports
o.c.clip spacing.Install per manufacturers details. Not for use FL116SI R3 AE FL11651 8 R3 24Versal-oc 18 IS-
in HVHZ Zones. 32Plvwood NonHVHZ-signed.odf
(rte Created by Independent Third Party:Yes
11651.9 24 Ga.Gulf Lok Min 24 Ga.Gulf Lok 16"Wide over 15/32"Plywood
Limits of Use Installation Instructions
Approved,for use in HVHZ: No FL11651 R3 II FL11651 9 R3 Metal Roo Panel Detail-
Approved for;use outside HVHZ:Yes signed.p_df
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes
Other:-81.75,psf @ 10-1/4"o.c.fastener spacing.-96.76 Evaluation Reports
psf @ 5-1/8"ox.fastener spacing.-121.75 psf @ 5-1/8" FL11651 R3 AE FL11651 9 R33 24GulfLok 16 15-
fastener spacing.-16i.psf @ 5-1/8"fastener spacing.Install 32Plvwood NonHVHZ-signed.odf
per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wG8VXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 3 of 6
4
l
j
Florida Building Code Online 8/9/19,1:01 PM
Referenced Standard and Year(of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/12/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
Go to Page �` ,l 0 0 Page 1/2 0 0
FL* Model,Number or Name Description
11651.1 0.032"Aluminum 5V Crimp Min 0.032"5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 lit FL11651 1 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-108.5 psf @ 12"o.c.Install per manufacturers Evaluation Reports
details.Not for use in HVHZ Zones. FL11651 R3 AE FL11651 a R3, 0325vCrimp 15-
32Plywood NonHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.2 0.032"Aluminum Gulf Lok Min 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 11 FL11651 2 R3 Metal Roof PanelDetail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-116.OPSF Created by Independent Third Party:Yes
Other:-52.5 psf @ 5 3/16"o.c.fastener spacing.-116.0 psf Evaluation Reports
@ 5 3/16"o.c.fastener spacing.Install per manufacturers FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
details.Not for use in HVHZ Zones. 32Plywood NonHVHZ-signed,p_df
i Created by Independent Third Party:Yes
11651.3 1"24ga. Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 3 R3 Metal Roof PanelDetail-
Approved fol use outside HVHZ:Yesgned.�df
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/--131.OPS Created by Independent Third Party:Yes
Other:-67.3 psf @ 24"o.c.clip spacing.-131 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 3 R33 1 24GulfSnap 17 15-
HVHZ Zones. 7plvwood HVHZ-sioned.pdf
Created by Independent Third Party: Yes
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 2 of 6
}
i
Florida Bliildfng Code Online 8/9/19,1:01 PM
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick bere.
Product Approval Accepts:
I }
1
r�
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2f TrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 6 of 6
Florida Building Code Online 8/9/19,1:01 PM
11651.16 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 11FL11651 16 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes 19119 .pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-63.5PSF Created by Independent Third Party:Yes
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports
psf @ 5 3/16"fastener spacing.-161 psf @ 5 3/16"fastener FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15-
spacing.Install per manufacturers details. Not for use in 32Plywood NonHVHZ-sioned.pdf
HVHZ Zones. Created by Independent Third Party: Yes
11651.17 26 Ga. GulfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-154.7PSF Created by Independent Third Party:Yes
Other:-59.25 psf @ 24"o.c.fastener pattern. -154.75 psf @ Evaluation Reports
12"o.c.fastener pattern.Install per manufacturer details. Not FL11651 R3AE FL11651 17 R3 26GulfPBRIS-
for use in HVHZ 32Pivwood NonHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.18 26 Ga.GulfPBR Min 26 Ga.GulfPBR Roof Panel over 1x4 Wood Purlins over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.p-df
Impact Resistant: N/A Verified By: Dan Kuhn, P.E.75519
Design Pressure: +N/A/-151.7PSF Created by Independent Third Party:Yes
Other:-100.5 psf @ 24"o.c,fastener spacing.-151.75 psf @ Evaluation Reports
12"fastener spacing.Install per manufacturer's details.For FL11651 R3AE FL11651 18 R3 26GulfPBR, 1x4 IS-
use in HVHZ Zones 32PlywooHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.19 26 Ga. GulfPBR Min 26 Ga.GulfPBR over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF Created by Independent Third Party:Yes
Other:-60.5 psf @ 24"o.c.fastener spacing.-154.75 psf @ Evaluation Reports
12"o.c.fastener spacing.Install per manufacturer's details. FL11651 R3 AE FL11651 19 R3 26GulfPBR 15-
For use in HVHZ Zones. 32P ywoodHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.20 26 Ga.GulfPBR Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No F111651 R3 II FL11651 20 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes A9119d.odf
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF Created by Independent Third Party:Yes
Other:-94.25 psf @ 24"o.c.fastener spacing. -151.75 psf @ Evaluation Reports r
12"fastener spacing.Install per manufacturer's details. Not FL11651 R3 AE FL11651 20 R3 26GulfPBR ix4 115-
for use in HVHZ Zones 32Plywood NonHVHZ-signed.6dr` / r
Created by Independent Third Party: Yes�� )
Go to Page 11 --� ._ �f 0 0 Pagel/20 0
Back I�Sext
Contact Us::2601 Blair Stone Road.Tallahassee R 32399r
Phone:850-467-1824 l
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f TrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 5 of 6
�r
VALGUO' lfCo"Uft
SUPPLY & MANUFACTURING
5 V
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
TM
Product Evaluation Report
GULF COAST SUPPLY&MANUFACTURING, LLC.
26 Ga. 5V Crimp Roof Panel over 15132"Plywood
Florida Product Approval #11651.12 R3
Florida Building Code 2017
Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30
Newberry, FL 32669 �,++""""'�•,,
• GEIV*S'•;X ;
Engineer Evaluator:
Dan Kuhn, P.E. #75519 =*' No.7W19--
Florida Evaluation ANE ID: 10743
STAT
E QF Q'
Validator: �F`•• �0
Locke Bowden, P.E. #49704sip •;• G��:�,r
9450 Alysbury Place �' NA ''���D/D�/20Zj
Montgomery, AL 36117
Contents: '
Evaluation Report Pages 1
f
FL#11651.12 R3 OCTOBER 5,2017
WIrA MIR7113MR111111110
• . ® . . . ® ® GuIfCo"i"' 9t
SUPPLY & MANUFACTURIWG
5 V
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
TM
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017,Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage,through fastened
roof panel with fasteners in the panel flat over minimum'%" plywood
decking. Non Structural application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 50.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3/8" Major Rib
Panel Fastener: #9-15x1.5" with sealing washing through panel rib.
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Substrate Description: Minimum 15/32" thick,APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/Florida Building Code 2017.
Design Uplift Pressures: Table"A"
Fastener Pattern Panel Rib Panel Rib
Design Pressure includes a Safety Factor=2.0.
t(l�
F"'1l
_ r
FL#11651.12 R3 OCTOBER 5,2017
PRO DUCT EVALUATION. REPORT
IrA 11111111111111101 IN MWIMIlliffiIIIIIIIIII
� . . ® . . � .
GulfCodft
SUPPLY & MANUFACTURING
5 V
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
TM
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• TAS 125-03
• UL 580-06-Test for Uplift Resistance of Roof Assemblies
• UL 1897-12-Uplift Test for Roof Covering Systems.
• TAS 100-95-Test Procedure for Wind and Wind Driven Rain
Resistance of Discontinuous Roof Systems
• TAS 110-00-Accel.Weathering ASTM G 155/Salt Spray ASTM
B 117.
Reference Data: 1. TAS 125-03: UL 580-94/1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization#TST 5328)
Report No. 117-0065T-07A-C, Dated 01/26/2007
2. TAS 100-95
Farabaugh Engineering &Testing, Inc. (FBC Organization#TST 1654)
Report No.T130-07, Dated 02/28/2007
Report No.T215-08, Dated 07/08/2008
3. TAS 110-00:Valspar Fluropon coated metal panel testing
A)ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004
B)ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004
4. Certificate of Independence
By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC -
(FBC Organization#ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
standard.
3. ASTM G 155 is equivalent to ASTM G26 `
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
FL#11651.12 R3.00TOBER 5,2017
. . REPORT
V�
. . r . . . �
o . e , ,
Gulf
SUPPLY & MANUFACTURING
5V i*
17 26 GA. 5VCRIMP ROOF PANEL OVER • •
TM
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including
Section 1515.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details and RAS 133.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2017 Section
1518.2, 1518.3, 1518.4.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire ratings of this roofing system assembly as well as the location of the
fire barrier within the assembly. Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10
using allowable stress design.The maximum fastener spacing listed herein shall
not be exceeded.
FL#11651.12 R3 OCTOBER 5,2017
. . , REPORT,
• ® ® • •
Gulf Coi'
1' •
SUPPLY & MANUFACTURING
5V '
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
TM
ENGINEER LOAD TABLE:26 Ga.SVCrimp Roof Panel over 15/32"Plywood
120 130 140 150 160 170 180
WAND FASTENER SUBSTRATE
SPEED
(MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER
Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING
ZONE 1 #9-15x1.5" Plywood 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1
ZONE 3 #9-15X1.5" Plywood 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1 12"TYPE 1
,ZONE 2 R�ROOF ZONE 3 Note:Dimension(a)is defined as 10%of the minimum width of the building or
a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be
----------------- less than either 4%of the minimum width of the building or 3 feet.
RIDGE
' - ---'' (1) #9-15 x 1-1/2" HWH w/Sealing Washer
zoNE1 ��` 12 12
��
------
\--SAVE At Panel Lap--/
ZONE Z GABLE ROOF }�
I
� I
jRIDGE
-..- i a
+---------------------•-f- a
i
I
ZONE 1
t
ZONES \-EAVE
FL#11651.12 R3.00TOBER 5,2017
• • e eLU • • •
T� ANIL Min M N ME