Loading...
HomeMy WebLinkAboutEngineering Arch itInc August 1, 2019 RECEIVED Saint Lucie County Building Department AUG 0 9 2019 Attn: Roof.Permit Plan Review 6T. Lucie County,Permitting 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 8001 James Road,St, Lucie County Manufacturer: Pglyglass USA, Inc. .Profiles: Pglyglass SBS and APP Modified Bitumen Roof Systems, FL#1654.1 System W-77 Code: FBC 2017;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 'l0112 Requires!Design Pressure: Zone1:-31.40 Zone 2:-49,61 Zone3:-68.97 Maximum Up{ift Pressure: Zone 1&2-60,Zone 3-90 _ Base: Certain Teed Giasbase Base Attachment: Zone 1&2,32 ga. 1-518"diameter tin caps with 11 ga.Annular ring shank nails @ 8"o.c. in a lap and 8"o.c. in three,equally'spaced, staggered center rows.Zone 3,32 ga. 1-5/r diameter tin caps with 11 ga.Annular ring shank nails @'4"o.c.in 4" lap and 4"o.c.'in three, equally spaced,staggered center rows. Cap: Tri-built AFP-TA(torch)Modified Bitumen torch applied Roof Decking: Existing 518" plywood sheathing to be nailed w 8d x 2"ring shank nails @ 6"Q.C.thru out Zane 1,4"O.C. perimeter&6"O.C.field Zone 2, and 4"O.C.thru out Zone 3. The above approved,as per Florida Building Code Compliance acceptances,2017 Florida Building Code, and the n :�cturer's recommendations. % �Q.4 d (S } oF Ft e pectfully Subm)t CODE COMPLI ANC. VIEWED FOR RE �r �GNNEL J 3, 44 ST. LUCIE.COUNT BOC AR 689 6.i M jc I Seal File tupy 806 Delaware Avenue Tel: 772 460 7755 www.architectonicinc:com fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 I of 2