HomeMy WebLinkAboutProduct Approval uacv fb monaa bunaing uoae unune
mmmw
n'all
"-.
BCIS Home ; Log In User Registration Hot Topic f Submit Surcharge # Stats&Facts Publications FBC Staff BCIS Site Map Unks ; Search'
blodda
a: t Product Approval
�
;x USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application De ta RECEIVED
Je,a. FL# FL17022-R7 I}
Application Type Revision AUG 12 `Ell q 4
Code Version 2017
Application Status Approved ST. LUCID COUtlty, PermlCting
Comments 08/18/2017v.date reapply 08/21/17
Archived
File
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive ®��`
Palm City,FL 34990 „� FOR
(772) 34 CODE COMPMANCE
flvalidation@yahoo.com
@yahoo.com
Authorized Signature Richard McKuhen ST. LUCOE C(DUyy
flvalidation@yahoo.com Back
r
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
;✓ Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRp/p2bGxHGxFe5QkCHzEgvOQveegp/o3dp/*3d 1/4
` 1/8/20118 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted _ 08/18/2017
Date Validated 06/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
S-U of Pro ets
L# Model,Number or Name Description
17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC.Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,
mechanically attached to 15/32"plywood or Wood Deck with
exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrDdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
.this report and applicable code sections of FBC.Refer to
manufacturer's installation instructions.
17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24ga ssrodf
Impact Resistant:No Verified By:Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed In this report and applicable code seam 24ga ssr.Ddf
sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.odf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
Installation method listed in this report and applicable code ALUMINUM ssr.odf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.5 5-"l in.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
https:/Iwww.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgv2aBOpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 214
1/8/2U(8 Florida Building Code Online
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
17022.6 6-"1 in.Nail Strip"(115) 1"rib height,16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to attached to 15/32"plywood or
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ:Yes ALUM ssr.odf
Impact Resistant:No Verified By:Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
installation method listed in this report and applicable code ALUM ssr.Ddf
sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.7 7-"1.5 in.Nail Strip"(115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr r)df
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/Al-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr oddf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8 8-"EMAX Rib"(R5) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
17022.9 9-"PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.Odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturers installation
instructions.
pack EJe>a
Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida is an AA/EEo employer.eooyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for oifidal communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 314
S
1
2160 SW Poma Drive
r
Palm City, FL 34990
772)872-8034
Sam
Compliant with Florida Building Code 2017(6ei ed.)
i
Compliant with Florida Product Approval Rule#611320-3
Compliant: Keystone Certifications
i
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32"plywood or Wood
Deck w/min.0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw*to penetrate
3/16" min.thru deck or 5/8"embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, &4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16"min.thru deck or 5/8"embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16"ox. 8"O.C. 6"o.c.
FASTENER SPACING (ALONG Panel width) 12"O.C. 12"O.C. 12"O.C. 12"O.C.
FASTENER SIZE 1 #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527
UL 580-06&1897-041 Test Report 1015893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2:1
, o•.low
Locke Bowden,P.E.does not have,not will acquire a financial int I ar� cQ igy6Adacturing or distributing products
under this evaluation. I
Locke Bowden,P.E.is not owned,operated,or controlled by awl coAparkorni63f turer,or distributing products under this
report. f ' A-041 741 •�� 7
far
r''�•' l�NAL �\
`rl:::�i1111
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2017 61h ed.
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference.
3.Products are compliant for State of Florida product approval per Rule 61G20-3.Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty,installation, recommended product use outside of this report.
Fasteners-
#9-1-1/2-Min.or
#10 x 1-112'Min.perTable A'for Row 5-V Gimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
�V
::i�\!�iii_'�/iti\�\�.�a:/•�cS�i:%ti:%:��fi�:�h��%\��i�/ri :i�C:�i�':•%%`•t���='•.
Deck:
-15W or greater Plywood,or
Wood plank
12'
OPTIONAL SIMMONS
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
9 x -1/2"Min. or #10 X 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Width
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank