HomeMy WebLinkAboutWind Load Calculation RECEIVED
s
A ewSouth AUG 2 1 2019
WINDOW SOLUTIONS ST. Lucie County, Permitting
2526 Okeechobee Blvd,West Palm Beach,FL 33409 m 561-712-9600•CRC 1330822
Property Information Building Information
Owner: VICTOR&LINDA BEATY Wind Zone: 170 MPH.
Address: 1551 S.BROCKSMITH ROAD Exposure Category: C
FORT PIERCE,FL 34945 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
Ilk Risk Category: II
1
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure q!ft_j Pressure(p f)
1 Int 25.25 37 7 37.8 -41.0
2 Int 54.50 56.50 7 35.9 -39.1
3 Int 54.50 56.50 7 35.9 -39.1
4 Int 52 37 7 37.1 -40.3
5 Int 52 37 7 37.1 -40.3
6 Int 23 28.50 7 37.8 -41.0
7 Int 52 37 7 37.1 -40.3
8 Int 52 37 7 37.1 -40.3
9 Int 52 37 7 37.1 -40.3
10 Int 52 37 7 37.1 -40.3
11 Int 36 37.50 7 37.8 -41.0
12 Int 52 37 7 37.1 -40.3
13 Int 52 37 7 37.1 -40.3
FILE U01""OPY
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.