HomeMy WebLinkAboutDesign pressure calcs it
[jot -
OVX
`�
- �-
I H T
ST@n
500 SW 12th Ave
- Deerfield Beach, FL 33442
WI
Ph 561-922-6747 N - OWS
Fax. 561-292-3562
Property Information Building Information
Owner: MORRIS,JOHN&GWENDOLYN Wind Zone: 170 MPH.
Address: 1720 TIMBERLAKE DR Exposure Category: C
FORT PIERCE,FL 34947 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) JHeight(in) Elevation(ft) Pressure(psf) LPressure(psf)
1 Int 60.13 30.00 7 37.2 40.4
_.._................................... ..........................................................._-._.......--......................._...................._........................................................................................................ ........--............................---..........._...---..._._........_.._._...................._....._..-.............-....................................................
2 Int 60.13 60.00 7 35.5 -38.7
------.. - ---..... ..._........ --............._..............._...............-- -..._............._...._._......_..__._._.......................--._..._... _._..._........_._..._._._ ._..............._......._...._......._........................--...........-
3 Int 60.13 59.88 7 35.5 -38.7
.........................._..................._..__..-.._..._......................__._............_...—._._......_.._................----......................_.._................._........_.................................._................---......................._1.1..__..._._....._ _...........
4 Int 60.13 59.88 7 35.5 138.7
_................................_......------._................- ........... __...- - --- ----- -----._...._.__.._._........---.._...................._.........._._..------.........................---......._..---
5 Int 46.88 33.75 7 37.6 -40.8
_._....._..--..............- ---.............-- ._....---.......-............. .............................---..._._....__..._...........-- -.....................-............_--.._...._...................................._..._......_......................................_......_._.........
......
6 Int 48.25 60.00 7 36.1 -39.3
-- - -..__...— --— -._..........---...-..__...__._._.._..............---.........._... _..-......---..... -----..............---- --
7 Int 48.25 60.00 7 36.1 -39.3
,I
I
Prepared in accordance with:ASCE 7-10.Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
r
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
OPENING (Location) IS THIS A PRODUCT ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBERF PSF (+)PS
+ PSF PSF TESTED DIMENSIONS MULLION REQ Y/N
( ) (-) (-) SIZE REQ Y/N/NA
1_ Int _ __. W.. _ 7/8"IMP 18-0918.03 55 55 37.2 40.4 60 x 60 60.1300.00 y N
2 Int W 7/8"IMP 18-0911.04 55 55 35.5 38.7 74 X 63 60.13x6o.00 y N
3 Int W 7/8°IMP 18-0911.04 55 55 35.5 38.7 74 X 63 60.13x59:88 N N
4 Int W 7/8"IMP 18-0911.04 55 55 35.5 38.7 74 X 63 60.13x59.88 N N
5 Int W 7/8°IMP 18-0911.04 55 55 37.6 40.8 74 X 63 46.88x33.75 N N
6 Int W 7/8°IMP 18-0911.04 55 55 36.1 39.3 74 X 63 48.25x60.00 N N
7 Int W 7/8"IMP 18-0911.04 55 55 36.1 39.3 74 X 63 48.25x60.00 N N