Loading...
HomeMy WebLinkAboutWind Load Calculation L 1 Property Information Building Information Owner: McNutt Wind Zone: 160 MPH. Address: 36 Nogales Exposure Category: B Port St Lucie,F134952 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: lI Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative NumberIF "Zone Width(in) Height{in) Elevation{ft) F Pressure(psf) L Pressure(psf) 1 End 107 84 7 28.6 -35.8 ......_.................._..........._. _._ _ __.—.._...__.................._....................._-----..__... — ...... --._........_.._ 2 End 113 84 7 28.5 -35.5 ................_.._. --------------- .._._ __._.....-- -- 3 Int 113 84 7 28.5 -31.3 RECEIVED AUG 2 2 2019 ST. Lucie County, Permitting IN *— U OPY F1 U. Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1