Wind Load Calculation
Property Information Building Information Owner: Cichocki Wind Zone: 160 MPH. Address: 5009 Palio Pines Cir Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 25.ft. Mean Roof Height: 15 ft. Risk Category: 11 Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 18 63 7 32.5 -43.5 2 Int 53 63 7 30.7 -33.5 3 Int ----53 63 7 30.7 -33.5 4 Int 53 63 7 30.7 -33.5 5 Int 53. _ 63 7 30.7 -33.5 6— Int 28 39 7 32.5 -35.2 7 Int 53 50.5 7 31.2 -33.9 RECEIVED AUG 2 2 2019 ST. Lucie County, Permitting Prepared,in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1