Wind Load Calculation
Property Information Building Information Owner: Frank Ocone Wind Zone: 150 MPH. Address: 6615 Gaviotta Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 74 65 7 26.3 -33.7 --_- 2 --- Int -- -- 93 95 7 25.2 -27.6 -- — _.._......... _._._...�._..._..........._....--_.—_ _.—_....----_........... — 3 Int 53 40 7 27.8 -30.2 4 End 112 - 60 7 25.7 -32.5 5 End 27 55 7 28.5 -38.1 _.._..._ .._......._..--- -..........---------------.--.-...._....----- ... --- ._...._..__.............._.. ---........_..... _.--....._......._ 6 Int 27 55 7 28.5 -30.9 7 Int 27 40 7 28.5 -31.0 8 Int 53 60 7 27.1 -29.5 RECEIVC-D AUG 2 2 2019 ST. Lucie County, Permitting FILL COP"'L Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1