HomeMy WebLinkAboutProduct Approval 4
MIAMI•DADE
® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) w«vv.miamidade.gov/economy
J.A. Taylor Roofing
302 Melton Drive
Fort Pierce, FL.34982
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami-Dade County) and or the AHJ (in areas other than-Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material falls to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Edge—Loc 1.0: x 16"wide x 24 ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and or manufacture of the product or process.Misuse of this NOA as an endorsement of an product,for
P Y
P
sales,'advertising or an other purposes shall automatically terminate this NOA. Failure to comply with an section of
g Y P rP Y P Y Y
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA-No. 14-0418.01 and consists of pages 1 through 5. AUG �` OR
The submitted documentation was reviewed by Freddy Semino J00 `ANCE
co
s`r, IJ (' OA No.: 18-1023.17
hIlAM1-DADS COUNTY `� ration Date: 01/09/2024
• ' FILE OP Page/ 0of 5
1
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Metal,Panels(Non-Structural)
Materials: Steel
Deck Type: Wood
Maximum Design Pressure —101.00 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
Edge-Loc 1.0 Length:various TAS 110 Corrosion resistant,prefinished,coated
Width: 16" galvanized,galvalume, standing seam,metal
Height: 1" panels.
Thickness 0.024"(24 ga.)
Min.Yield Strength: 50 ksi
Trim Pieces Length:varies N/A Corrosion resistant,prefinished,coated
Width:varies galvanized,galvalume, standing seam,metal
Thickness 0.024"(24 ga.) panels.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Valspar 433X515 ASTM B 117 11/21/11
Valspar 433B173 ASTM D 4587,ASTM G 23 11/21/11
Force Engineering&Testing 72-0314T-06A-C TAS 125 03/24/07
Inc.
Farabaugh Engineering and T158-07A TAS 100 04/14/07
Testing Inc.
NOA No.: 18-1023.17
CM1AM1-MQADEMC0=UrNMW Expiration Date: 01/09/2024
Approval Date: 12/20/2018
Page 2 of 5
`1
APPROVED ASSEMBLIES:
System: Edge-Loc 1.0 Panel x 16"Wide x 24 ga. Steel
Deck Type: Wood,Non-Insulated
Deck Description: New Construction 19/32"or greater plywood or wood plank, or for re-roofing 15/32"or
greater plywood.
Slope Range: 2": 12" or greater
Maximum Uplift See Table A below
Pressure:
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6"o.c.In reroofing,where the deck is less than 19/32"thick(Minimum
15/32")The above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side-lap and 6" end-laps. Underlayment shall be fastened with corrosion resistant tin-caps
and 12 gauge 1 '/4" annular ring-shank nails, spaced 6" o.c. at all laps and two staggered
rows 12"o.c.in the field of the roll. Or,any approved underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation# 1.
Valleys:' Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Metal Panels and Install the "Edge-Loc 1.0 Panel' and accessories in compliance with the current published
Accessories: installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley'construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with corrosion resistant#10-13
x 1"pancake head screws of sufficient length to penetrate through the sheathing a minimum
3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas . Field Perimeter and Corner'
Maximum Design Pressures —59.75 psf —101.00 psf
Maximum Screw Spacing 16"o.c. 6.75"o.c.
1. Extrapolation shall not be allowed
NOA No.: 18-1023.17
Muv�ao�+neCauwrr Expiration Date:01/09/2024
Approval Date: 12/20/2018
Page 3 of 5
7
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones(i.e.perimeters,extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement:, "Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
MIAMI•DADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine models#'s 5521095 and 7031100 from PAC Contractors
Association.
NOA No.: 18-1023.17
MIAMI-DADE COUNTY Expiration Date:01/09/2024
Approval Date: 12/20/2018
Page 4 of 5
r
PROFILE DRAWINGS
16"
1"
Z\-
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
0
0
0
0
o FASTENER
o SPACING AS PER
TABLE A HEREIN
EDGE-LOC 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 18-1023.17
MIAMI- ADECO NTY Expiration Date:01/09/2024
Approval Date: 12/20/2018
Page 5 of 5
i
c
E
BCIS Home Log In User Registration ; Hot Topics t Submit Surcharge ' Stats&Facts ; Publications ( FBC Staff s BCIS Site Map Links ? Search
h� 'fid
Product Approval
r 0 USER.Public User
Product Aporoval+gnu>Prgduct or Aopiiotion Search>Application list>Application Detail
FL_# FL12328-R%8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerrLeden@tamko.com
i
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
-` Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
�/F�FF;zCId£
Certificate of Independence FL12328 R8 COI TBP14001 T M ��
Underlavments finaLpdf
®®G C IAN
Referenced Standard and Year(of Standard) Standard tq-ry
ASTM D1970 ST. LUCIEk2016
ASTM D226
ASTM D4869 ASTM D6380
TAS 103
FILE
E C®P
Equivalence of Product Standards
Certified By
i
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL itModel,Number or Name Description i
12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001 4 2017
-FBC Eval Report TAMKO i
Approved for use outside HVHZ:Yes Underlayments final yd
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
' FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes_
12328.2 ASTM Tile Underlayment Coated organic underlayment —
Limits of Use Installation Instructions —i
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final Ddf
Impact Resistant:N/A Verified By:Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL1232l�R8 AE TBP14001 4 2,017 FBC Eval Report TAMKO
Underlayments final.p-df I
— —--Created by Independent Third Party:Yes —
a-
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits of Use — Installation Instructions
Approved for use in HVHZ:No FL12r8 R8 Il TBP14001 4 2017 FBC Eval Report TAMK4
Approved for use outside HVHZ:Yes Underlayments final Ddf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 RS AE TBP]4001 4 2017 FBC Eval Report TAMKO
Underlayments finai.pdf
Created by Independent Third Party: Yes i
I
_.._...._.............------.---_.___.—._._...._..........................
.__—_ _
12328.4-- Moisture Guard — A self-adhering modified bitumen underlayment.
Limits of Use Installation Instructions �I
Approved for use in HVHZ:Yes FL12328 R8 II TBP14Q01.4 2017 FBC Evai Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.Ddf .
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
L12 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlayments ppdf
Created by Independent Third Party:Yes
12328.5 No. 15 ASTM Asphalt saturated organic felt T W I
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use; Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.6 No. 15 UL Asphalt saturated organic felt _ M
Limits of Use Installation Instructions
i
Approved for use in HVHZ:Yes FLI2328 R8 II TBP14001.4 2017 FBC Eva]Report TAMKQ
Approved for use outside HVHZ:Yes Underlayments final pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.adf
Created by Independent Third Party:Yes -`�
12328.7 No.30 ASTM Asphalt saturated organic felt
-_- _ ---_....._...__............----------__------------ -
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL12328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pd,
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design P:eassre:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments finaLDdf i
Created by Independent Third Party: Yes }
12328.8 No.30 UL Asphalt saturated organic felt
__ _..._. _ ...._.__._. _........................_......_ .........._.___.........._..... _ .............._....._
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.12df
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 EBC Eval Report TAMKO
Underlayments final Ddf
Created by Independent Third Party:Yes
'3
12328.9 TAM-FELT Alternate to ASTM D 226,Type II underiayment j
Limits of Use. Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
j Approved for use outside HVHZ:Yes Underlayments fiinal pelf
Impact Resistant:N/A Verified By:Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes i
Other:See evaluation report for limits of use. Evaluation Reports ]
FL1232.8 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlayments final Ddf
Created by Independent Third Party:Yes
12328.10 �- TW Metal and Tile Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions _
Approved for use in HVHZ:Yes FL12328 R8 fI TBP14001.4 2017 FBC Eval Report TAMK0
Approved for use outside HVHZ:Yes Underlayments final.Ddf
Impact Resistant:N/A Verif ed By:Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
_ - 112328 98 AE TBPj,4001 4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes i
_._
12328.11 TW Underlayment self-adhering modified bitumen underiayment --�
Limits of Use Installation Instructions
Approved for Luse in HVHZ:Yes FL12328 R8 IT TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odf I
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
EL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final Of ]
- _ — Created by Independent Third Party:Yes
Caack Next
Contact Us::2601 Blair Stone Road Tall hasty FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do nut want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide.the Department with an email address if they have
one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the.Department with an email address which can be made available to the public To determine if you are a licensee under chapter 455,F.S.,
please dick bffe,
Product Approval Accepts:
Certificate of Authorization No. 29824
REEK
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6P EoiTION(201?)
Manufacturer: TAMKO BUILDING PRODUCTS,INC. issued October 19, 2017
P.O. Box 1404 -
Joplin,MO 64802
(417)624-6644
http://www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underiayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DEscitipmltl
TAMKO@ ASTM Slate ASTM D 6380,Class M,Type it underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO@ ASTM Tile ASTM D 6380,Class M,Type Ii underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO@ Master ASTM D 6380,Class S,Type N underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
,TAMKO@ Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard@ with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO@ No.15 ASTM ASTM D 226,Type i underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO(D No.15 UL ASTM D 226,Type 1 underlayment constructed from a non-perforated organic feat that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@)No.30 ASTM ASTM D 226,Type ii underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@ No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@)TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO@)TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shalt notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not
specifically addressed herein.
i
� ����� TAMKO BUILDING PRgDCUTS,INC.
TAMKO Underiayments
TECHNICAL SERVICES,LLC
TAMKO@ TAM-FELT Alternate to ASTM D 226,Type I and Type It underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBG, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements, Roof decks shall have,no more than 1/8° gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO@ TW Metal and Tile Underlayment and TAMKO(&TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO@ Moisture Guard®shall be 35°F.
The minimum roof slope shall be in accordance with FBG requirements except as follows:
a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underiayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMK0@ TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering undedayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverin s:
Metal RoofMineral Wood
AsphaltPanels and Surfaced Rol( Shingles and,. slilk Clay and.,
Underly meet; Shin'les Shingles Roatin Shakes Shineles concrete Tile.
TAMKO@ ASTM Slate Y' N N N N Y
Surfaced Roll Rooting
TAMKO@ ASTM Tile N N N N N Y
Underlayment
TAMKOO Master Smooth Y' N N N N N
TAMKO@ Moisture GuardO Y N N N N N
TAMKO@ No.15 ASTM
Asphalt Saturated Organic Y Y Y Yz N N
Felt
TAMKO@ No.15 UL Asphalt Y Y Y Yx Y N
Saturated Organic Felt
TAMKO@ No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKO@ No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOS TW Metal and Tile Y Y N N N Y
Underlayment
TAMKOO TW Undoriayment Y Y N N N N
TAMKOO TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
R L.y LE" TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources; the more restrictive and FBC
compliant installation detail.sOall;prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave,and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturers application instructions,
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAPA93-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM 0 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D
1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-RS Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
i
TAMKO BUILDING PRODCUTS,INC.
CREEKTAMKO Underlayments
TECHNICAL_SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P,E. have demonstrated compliance with the Florida Building
Code,6N'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
vis R tetr
2017.10.1
��.. ••'\CENS.• �r
•
No 74421 = 12.15:58
— * 04'00'
�• STATE OF :•J
s00
.T *. P �: Zachary R.Priest, P.E.
SC 1 t3• G1`� Florida Registration No.74021
r;s O N A� alt Organization No,ANE9641
CERTIFICATION OF INDEPENDENCE
i
CREEK Technical Services,LLC does not have,nor will it acquire.a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product,
i
END OF REPORT
TBP14001 A FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein..