Loading...
HomeMy WebLinkAboutProduct Approval 1 v _�.. A U G >. r ST. Lucie County, P4i•mitl;ing 5 • NNEMOletc. LAPTENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 3A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-8 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 1D Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10-11 1E Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 12-14 1F-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-17 IF-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-19 1G Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 19 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 20-22 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 23-27 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 28-30 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-38 3B Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 38 3C Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 39 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 40-43 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4446 4C Lightweight concrete New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47-52 4D Lightweight concrete Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 52 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 53 58 Cementitious wood fiber New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54 5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 55 5D Cementitious wood fiber New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 56-58 6B Existing gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 58-59 6C Existing gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 59 6D Existing gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 61-67 7B Various Recover F Non-Insulated,Bonded Roof Cover 67 NEMO ETC,LLC Evaluation Report 3520.03.04-R23 for FL2533-R22 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 1 of 67 c. NNEMOletc. The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in.Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round insulation Plate,Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-Inch plywood penetration or minimum 1-Inch wood plank embedment. ➢ Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG#12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG HD or CD-10 with OMG 3 in.Galvalume Steel Plate,Dekfast#14 or DekSpike with Hex Plate or 3"Round Insulation Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FI1ntFast#14 Fastener with FllntFast 3"Insulation Plates. Minimum 1-Inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perilte,GlasRoc Roof Board or gypsum-based roof board that meets the QA requirements of F.A.C.Rule 61620-3 and Is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight Insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover), whereby the base sheet screws and plates are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted In the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 lbs/square ➢ Ashland Pliodeck(A-PD): Continuous 0.75 Inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. ➢ Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1 Inch wide ribbons,12-Inch o.c. ICP Adhesives Polyset BOARD-MAX: Continuous 3-inch ribbons,12-Inch o.c. ICP Adhesives Polyset CR-20: Continuous 2.5 to 3-inch wide ribbons,12-Inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive(M-PGS): Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500 or OlyBond Green(OB500): Continuous 0.75-Inch wide ribbons,12-inch o.c.(PaceCart or SpotShot) D Note: When multiple layers(s)of Insulation and/or coverboard are installed in ribbon-applied adhesive,boards shall be staggered from layer-to-layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: Ashland Pliodeck(A-PD)@ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch) D Ashland Pllodeck(A-PD)@ 6-inch o.c. MDP -277.5 psf (Min.1.0-Inch) Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): MDP -120.0 psf (Min.1.0-inch) ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min.1.0-inch) Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.1.0-inch) Millennium PG-1 Pump Grade Adhesive(M-PGI): MDP -157.5 psf (Min.1.0-inch) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch Multi-Max FA3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch 150 95+GL) D OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-Inch ENRGY 3) OMG OlyBond 500(013500): MDP -487.5 psf (Min.0.5-Inch ACFoam 11) NEMO ETC,LLC Evaluation Report 3520.03.04-R23 for FL2533-R22 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 Prepared by: Robert Nleminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 2 of 67 r ONEMOletc. 8. Bonded polyisocyanurate Insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone i design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 30. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing In accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Concrete Deck or Recover Applications using System Type D,the insulation is optional. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C350),with no proprietary additives,In accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted,use of these listings in new construction or re-roof(tear-off)applications Is at the discretion of the Designer of Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. CERTAINTEED FUNTLASTIC"MODIFIED BITUMEN COMPONENTS&APPLICATION METHODS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 (Base and Ply sheets,Asphalt-Applied) Ply One or more Flintglas Ply 4;Flintglas Premium Ply 6 Hot asphalt at 20-40 lbs/square BP-AA2 Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in (Base,Spot-Asphak-Applied) 30-inch grid pattern BP-AA3 Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid (Base,Spot-Asphalt-Applied) Ipattern noted herein. BP-AA4 Base Yosemite Venting Base Hot asphalt in 9-Inch wide ribbons spaced (Base,Strip-Asphalt-Applied) as noted herein. BP-CA2 Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Henry#903 Adhesive at 1.5 gal/square BP CA3 Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Millennium Hurricane Force Membrane Adhesive,beads spaced 6-inch o.c. Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS-AA Ply One or more Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 lbs/square (SBS,Asphalt-Applled) Cap Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar;Flintlastic Premium FR-P;Flintlastic GMS;Flintlastic GMS CoolStar NEW ETC,LLC Evaluation Report 3520.03.04-1123 for FL2533-1122 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 3 of 67 ONEMOletc. .. .. . REFERENCE LAYER MATERIAL APPLICATION Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Karnak No.81 Cold SBS-CAI (SBS,Cold-Applied) Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Process Modified Bitumen Adhesive Brush Cap FIIntlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P Grade at 1 gal/square CoolStar;Flintlastic Premium FR-P;Flintlastic GMS;Flintlastic GMS CoolStar Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS-CA2 Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. (SBS,Cold-Applied) Cap Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar;Flintlastic Premium FR-P;Flintlastic GMS;Flintlastic GMS CoolStar Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS-CA3 Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Millennium Hurricane Farce Membrane (SBS,Cold-Applied) Cap Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P Adhesive,beads spaced 6-inch D.C. CoolStar;Flintlastic Premium FR-P;Flintlastic GMS;Flintlastic GMS CoolStar Base FIIntlastic Ultra Poly SMS Base;Flintlastic Base 20 T SBS-TA Ply One or more Flintlastic Ultra Poly SMS Base;Flintlastic Base 20 T Torch-Applied (SBS,Torch-Applied) Cap Flintlastic FR Cap 30 T;Flintlastic FR Cap 30 T CoolStar;Flintlastic GTS-FR Base One or more Flintlastic APP Base T;Flintlastic STA;Flintlastic STA Plus APP-TA Cap Flintlastic STA;Flintlastic STA Plus;Flintlastic GTA;Flintlastic GTA CoolStar;Flintlastic GTA-FR;Flintlastic GTA-FR Torch-Applied (APP,Torch-Applied) CoolStar SBS-SA-H Base/Ply Black Diamond Base Sheet;Flintlastic Ultra Glass SA Self-Adhering (SBS,Self-Adhering,Hybrid Systems) Base FIIntlastic SA PlyBase;Flintlastic SA Mid Ply SBS-SA Ply Flintlastic SA PlyBase;Flintlastic SA Mid Ply Self-Adhering (SBS,Self-Adhering) Cap Flintlastic SA Cap;Flintlastic SA Cap FR 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following MDP limitations. The lesser of the MDP listings below vs.those In Table 3A applies: F VAPOR BARRIER OPTIONS; . . . D•listings below vs,.those in Table 3A applies) OPTION PRIMER TYPE VAPOR BARRIER ATTACH INSULATION ADHESIVE MDP(PSF) VB-1. FlintPrime Flintlastic SA PlyBase Self-adhering OB500,12-Inch D.C. -82.5 VB-2. FlintPrime Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch D.C. -420.0 VB-3. FlintPrime Flintlastic Base 20 T,Flintlastic FR Cap 30 T or Flintlastic GTS Torch-applied M-OSFA or M-PG1,12-Inch D.C. -495.0 17. "MDP"=Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 3520.03.04-R23 for FL2533-R22 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)6Si-5847 Appendix 1,Page 4 of 67 ONEMOjetc. BONDEDTABLE 117-1: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAk-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET, ROOF COVER SystemDeck Base Sheet Roof Cover(Note 15) MDP No. F (Note 1) Base Fasteners Attach Ply Cap (psf) SELF-ADHERING SYSTEMS: 9-Inch o.c.at min.3-inch lap and 12-Inch o.c.in W-57 Min.15/32-inch plywood at Flintlastic SA NailBase Simplex MAXX Cap two(2),equally spaced,staggered center rows; (Optional)SBS- SBS-SA -45.0• max 24-inch spans Stress plates shall be primed with FlintPrime SA (ASTM D41)primer. W-58 Min.15/32-inch plywood at Flintlastic SA NailBase Min.1-Inch long,12 ga.Simplex 6-Inch o.c.at min.2-inch lap and 6-inch o.c.in (Optional)SBS- SBS-SA -52.5 max 24-inch spans Metal Cap Nails four(4),equally spaced,staggered center rows SA Min.19/32-inch plywood at 32 ga.,1-5/8-Inch dia.tin caps 8-Inch o.c.at min.2-inch lap and 8-Inch o.c.In (Optional)SBS- W-59 max.24-inch spans Flintlastic SA NailBase with it ga.annular ring shank three(3),equally spaced,staggered center SA SBS-SA -52.5 nails rows 32 ga.,1-5/8-inch dia.tin caps 8-Inch o.c.at min.2-inch lap and 8-inch o.c.in Min.19/32-inch plywood at (Optional)SBS- W-60 max.24-inch spans Flintlastic SA NailBase with 11 ga.annular ring shank three(3),equally spaced,staggered center SA SBS-SA -60.0 nails rows 8-Inch o.c.at min.3-inch lap and 8-Inch o.c.in W-61 Min.15/32-inch plywood at Flintlastic SA NailBase Simplex MAXX Cap three(3),equally spaced,staggered center (Optional)SBS- SBS-SA -67.5 max 24-inch spans rows;Stress plates shall be primed with SA FlintPrime(ASTM D41)primer. Min.19/32-Inch plywood at 32 ga.,1-5/8-inch dia.tin caps 6-Inch o.c.at min.2-inch lap and 6-Inch o.c.in (Optional)SBS- W-62 max 24-inch spans Flintlastic SA NailBase with 11 ga.annular ring shank four(4),equally spaced,staggered center rows SA SBS-SA -75.0 nails Cap nails:1-Inch diameter, W-63 Min.15/32-inch plywood at Flintlastic SA NailBase 0.032-Inch thick metal cap with 7-Inch o.c.at min.4-inch laps and 7-Inch o.c.in (Optional)SBS- SBS-SA -75.0 max 24-inch spans 0.120"shank diameter,annular five(5),equally spaced,staggered center rows SA ring shank nails Min.19/32-inch plywood at 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch lap and 4-Inch o.c.in (Optional)SBS- W-64 max 24-inch spans Flintlastic SA NailBase with it ga.annular ring shank four(4),equally spaced,staggered center rows SA SBS-SA -105.0 nails HYBRID SYSTEMS: Glasbase;Flexiglas;Flintlastic 32 ga.,1-5/8-inch dia.tin caps W-65 Min.19/32-inch exterior grade Base 20;All Weather/Empire with 11 ga,annular ring shank 9-inch o.c.at 4-inch lap and 12-Inch o.c.in two SBS-SA-H SBS-AA,SBS-TA -45.0" plywood at max.24-inch spans Base;Poly SMS Base;Ultra Poly nails (2),equally spaced,staggered center rows or APP-TA SMS Base `Glasbase Fleziglas;_Flintlastic� (Min 15/32 inch plywood at} (Base 20 All Weather/Empires ,Min.1 Inch long 12 gaTSimplexi �6 Inch 6.E-.'-t4aihch lap and 6 mch o c in fourl 5B$AA;-SBS-TA) _ SZ W-� SBS SA H) max:24 mch spansr Base Poly_SMS Base Ultra Poly) ,Mefal Cap Nails (4} equally spaced;staggered center�ows� -—-- or APP-TA .SMS Basel NEMO ETC,LLC Evaluation Report 3520.03.04-R23 for F1.2533-1122 Certificate of Authorization#32455 6r'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 23:04/17/2019 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 15 of 67