Loading...
HomeMy WebLinkAboutProduct Approval (2) 8/16/2019 Florida Building Code Online BCIS Home Log In User Registration Hot Topics i Submit Surcharge t Stats&Facts Publications Contact Us BCIS Site Map ( Links Search fld Product Approval KI USER:Public User Product Al2proval Menu>Product or Application Search>application List>Application Detail • FL# FL14911-R11 Application Type Revision Code Version 2017 Application Status Approved Comments Archived i i Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 jonberrian@slbp.com Authorized Signature ]on Berrian jonberrian@slbp.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 jonberrian@slbp.com i Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional.Engineer =1 Evaluation Report-Hardcopy Received I Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Locke Bowden P.E. RJ Validation Checklist-Hardcopy Received Certificate of Independence FL14911 R11 COI COI Silverline SS 2017-06-14.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA/101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 ASTM E1996 2012 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 httls://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx21btdSCx8gXOAG%2bvoMHV6Fk8dHGU%2f4khcg%3d%3d 1/3 8/16/2019 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code I Product Approval Method Method 1 Option D Date Submitted 08/17/2018 i Date Validated 10/14/2018 Date Pending FBC Approval 10/08/2018 Date Approved 10/18/2018 Summary of Products FL# Model,Number or Name Description 14911.1 VI Series/50 Series(2000) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R11 II SWD017 SS 2018-10-11.pdf j Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5140 SS 2017-10-20.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.2 V1 Series/50 Series(2111) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R11 II SWD018 SS 2018-10-11.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5141 SS 2017-10-20.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. I 14911.3 V1 Series/50 Series(2200/2300) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R11 II SWD019 SS 2018-10-11.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5142 SS 2017-10-20.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.4 V1 Series/70 Series(2127) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14911 R11 II SWD049 SS 2018-10-11.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5485 SS 2018-02-14.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.5 VI Series/70 Series(2127) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14911 R11 II SWD050 SS 2018-10-11.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5486 SS 2018-04-19.Qdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.6 V1 Series/70 Series(2907/4907) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R11 II SWD053 SS 2018-10-11.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDquZRj59%2fDrx21btdSCx8gXOAG%2bvoMHV6Fk8dHGU%2f4khcg%3d%3d 2/3 8/16/2019 Florida Building Code Online Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports e Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5884 SS 2018-08-17.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. j Sack NoxX Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.QWylight 2007-2013 State of Florida.::Privacy Statement::Accessibillty Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: I Gres It j0*41 I I I i I I it I I I hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDquZRj59%2fDrx2lbtdSCx8gXOAG%2bvoMHV6Fk8dHGU%a2f4khcg%3d%3d 3/3 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every.Drop! Dania Beach, FL 33004 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@.buildingdrops.com Product EvaWati®n Report -of Silver Line Windows & Doors V1 Series/70 Series.Single Hung Window (2907/4907) .Extruded Vinyl Window w/Flange for Florida Product Approval --FL# FL149 1 Report No. 5884 Current Florida:Building Code 'Method: 1— D (Engineering-Evaluation) Category.: Windows l' Sub—Category: Single Hung I Product: V1 Series/70 Series Single Hung Window .(290714907) Material: Vinyl Prod uct'Dimensions: Refer SWD053 for.Dimensions -Prepared For: Silver Line Building Products Corp. One S6lverline Drive North Brunswick, NJ 08902 j Prepared by: Hermes F. Norero, P.E. ,�` .. 0.... .• Florida Professional Engineer#73778 '�� �� ES•• 'rC)'s Date: 08/15/2018 N Contents: "a S A OF Evaluation Report Pages 1—3 70 0,� _ O lDP':• �!/� Digitally signed by Hermes F.Norero,P.E. Reason:I am approving this document Date:2018.08.17 17:33:15-04'00' H e rm ens'F1 NA#06"P.E. Florida No.73778 5 BUILDING DROPS FL#: FL14911 A\\ A-Perfect Solution in Every Drop! Date: 08/15/2018 Certificate of Authorization:_29578 Report No: :5884 Manufacturer: Silver Line Building Products Product Category: Windows Product Sub-Category: Single/Triple Hung Compliance Method: State Product Approval Method (1)(d) Product Name: V1 Series/70"Series-Single Hung Window(2907/4907) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for-Silver Line Building Products-based on Method 1d of the State of Florida Product Approval, Florida.Department i of"Business and Professional Regulation- Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. i See Installation.Instructions SWD020,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris-protection this product complies with Chapter16 of the current Florida Building Code and does require an impact resistant covering. '5. Site conditions that deviate from the details of drawing SWD053 require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions.SWD053 for size and design pressure limitations. i I I Hermes F. Norero, P.E. Florida No.73778 Page 2 of 3 1 'BUILDING DROPS FL#: FL14911 A Perfect Solution in Every'Drop! Date: 08/15/2018 Certificate.of Authorization:29578 Report No: 5884 Quality Assurance Entity: The"manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window-and Door Manufacturers Association (FBC Organization #QUA2515). Performance.Standards: The product described herein has been tested per: • AAMA/WDMA/CSA 101/I.S.2/A440-11 Referenced.Data: 1. Product Testing performed by Architectural Testing, Inc. (FBC'Organization#TST1795) Report#:ATI E5613.01-109-47 Report Date: 03/03/2015 Report#:ATI G1000.01-109-47 Report Date: 08/08/2016 Report#: ATI C7073.01-109-47 Report Date: 06/17/2013 Report#:ATI G8077.01-109-47 Report Date: 03/29/2017 Report#: ATI D2935.01-109-47 Report Date: 12/30/2013 Report#:ATI G0996.01-109-47 Report Date: 08/02/2016 Report#:ATI C4709.01-109-47 Report Date: 01/11/2013 Report#: ATI D5514..01-109-47 Report Date: 03/18/2014 2. Quality Assurance Entity Window and.Door Manufacturers.Association (FBC Organization•#QUA2515) Installation Method:• Please refer to installation instructions,SWD053,for anchor methods,selection, spacing, edge distances, embedment's and further details of installation. Design Pressure: Please refer to installation instructions,SWD053,for mull combination grouping, configurations, and corresponding design pressures. i . Hermes F. Norero, P.E. Florida No.73778 Page 3 of 3 SINGLE-HUNG WINDOWS (290714907) DESIGN PRESSURE TABLE TABLE OF CONTENTS SIZE CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING SHEET REVISION SHEET DESCRIPTION AND RRENT EDITION 40.0"X 68.0" O/X +35/-35 PSF NON-IMPACT 1 - GENERAL NOTES&GLAZING DETAILS HVHZ HAS OWING: 44.0"X 60.0" O/X +35/-35 PSF NON-IMPACT 2 - ELEVATION&ANCHOR LAYOUTS 11 48.0"X 84.0" O/X +20/-20 PSF NON-IMPACT 3 - ELEVATION&ANCHOR LAYOUTS 80.0"X 84.0" O/X-O/X +15/-15 PSF NON-IMPACT 4 - ELEVATION&ANCHOR LAYOUTS IETAL FRAMING 64.0"X 68.0" O/X-O/X +35/-35 PSF NON-IMPACT 5 - VERTICAL SECTIONS CAPABLE OF' 80.0"X 82.0" O/X-O/X +20/-20 PSF NON-IMPACT 6 - HORIZONTAL SECTIONS :D PRODUCT ISIBILITY OF THE 90.0"X 84.0" O/X-O/X +15/-15 PSF NON-IMPACT 7 - ANCHOR DETAILS HE PROJECT OF 71.5"X 60.0" O/X-O/X +35/-35 PSF NON-IMPACT _ 8 ANCHOR STRAP DETAIL,INSTALLATION NOTES AND SCHEDULE ESIGNED AND 107.0"X 62.0" O/X-O/X-O/X +35/-35 PSF NON-IMPACT ADS TO THE 107.0"X 74.0" O/X-O/X-O/X +20/-20 PSF NON-IMPACT ON IS THE ITECT OF RECORD EIN ARE GENERIC IS FOR A SPECIFIC ON TO DEVIATE N,A LICENSED TE SPECIFIC JT IN NON-HVHZ 43/64"O.A. INSULATED GLASS REQUIRED ON GLAZING NOTES: T RESISTANCE. EXTERIOR INTERIOR 1. GLASS TYPE&THICKNESS SHALL COMPLY WITH ASTM E1300 REQUIREMENTS AS WELL AS APPLICABLE SAFETY GLAZING REQUIREMENTS PER THE FBC.TEMPER AND SAFETY GLAZING REQUIREMENTS SHALL BE ASTM E 1300 STEEL SPACER REVIEWED ON A SITE SPECIFIC BASIS. )ETAILS. 2. SETTING BLOCK DUROMETER HARDNESS OF 70-90(SHORE A)AS I 1 REFERENCED IN FBC CHAPTER 24. 3. SETTING BLOCKS TO BE LOCATED AT 1/4 SPAN LENGTH FOR GLASS WIDER \ Q 1/2" MIN. THAN 36"AS PER FBC CHAPTER 24. DGLASS BITE 4. D.L,0.AND DESIGN PRESSURES MAY NOT EXCEED MAX VALUES IN GLASS ,u uCHARTS. GLAZING DETAIL A B 5 5 PF OPP. --- - -- '- -- - --- -- 11011 6 -- - - -- UNIT MAX. HEIGHT SEE SHEET 1 PA OPP. X11 6 QUALIFIED CONFIGURATIONS ELEVATION ARCH TOP CONFIGURATIONS FOR ALL 2907-4907 RATINGS,SINGLE UNIT CONFIGURATIONS 2.0" FROM 11.0" MAX. ry CORNER(TYP.) (TYP.) 4 "O" 11011 11.0"MAX. (TYP.) T i ANCHOR SCHEDULE PRODUCT FROM MAX. O.C.AT MAX.O.C.AT SIZE CORNERS HEAD JAMBS 40.0"X lixti ��X�� 68.0" 6" 14.0" 18.5" 44.0"�X 6" 16.0" 16.0" 60.0 2.0"FROM 48.0"�X 6" 18.0" 24.0" CORNER(TYP.) 84.0 ANCHOR LAYOUT 5 5 E D OPP. - 6 11011 6 F B " 7 O" 6 UNIT MAX. HEIGHT SEE SKEET 1 C Opp.6 A „ '„ X1� X 6 ELEVATION QUALIFIED CONFIGURATIONS ARCH TOP CONFIGURATIONS FOR ALL 2907-4907 RATINGS,TWIN UNIT CONFIGURATIONS MAX. O.C.(TYP.) 2.0"FROM 11.0"MAX. :E TABLE BE OW CORNER(TYP.) (TYP.) "Oil Oil ��0�� ANCHOR SCHEDULE 11.0"MAX. PRODUCT FROM MAX.O.C.AT MAX.O.C.AT (TYP.) SIZE CORNERS HEAD JAMBS 80.0"X 84.0" 6" 22.5" 24.0" 64.0"X 68.0" 6" 17.25" 11.0" IV �� X fixii 80.0"X 82.0" 6" 22.5" 17.5" X 90.0"X 84.0" 6" 19.5" 24.0" 2.0" FROM ANCHOR STRAP 71.5"X 60.0" 6" 19.75" 12.0" CORNER(TYP.) T , v/ni ---- -- E------ - / E 0 OPP. --- --- - -----NF "O" 6 11oil ItOil g B 6 5 6 UNIT MAX. -HEIGHT - - SEE SHEET 1 6 IxT.x. Ix.A 0 MAX. O.C.(TYP.) ELEVATION 2.0"FROM 11. MAX. rYP.) SEE TABLE BELOW CORNER(TYP.) (TYP.) / 11.0"MAX. r (TYP.) "Oil 110" "O" I" „11� �1 I" X X 11 X X X X 2.0"FROM /r rr rr CORNER(TYP.) ANCHOR STRAP P/N 50-2995-2 ANCHOR LAYOUT SEE SHEET 8 FOR DETAILS ANCHOR LAYOUT NAIL FIN THROUGH FRAME ANCHOR SCHEDULE JCT FROM MAX.O.C.AT MAX.O.C.AT CORNERS HEAD JAMBS X 611 24.0" 7.0" X 611 24.0" 12.25" 1/811 ° C� SEE GLAZING SEE GLAZING DETAIL SHEET 1 DETAIL SHEET 1 MAX. D.L.O. HEIGHT ' MAX. Q ri I>t O FRAME 1R p INTERIOR HEIGHT EXTERIOR p INTERIOR O O MAX. D.L.O. SEE GLAZING HEIGHT SEE GLAZING DETAIL SHEET 1 DETAIL SHEET 1 0 0 0 p . 0 0