NOTICE OF ACCEPTANCE NOA www.mia dade.aov/econom
GAF AUG 2 6 "M
1 Campus Drive
Parsippany,NJ 07054 ST. Lucie County, Permitting
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction'(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke,modify, or suspend the use of such product or material within
their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade
County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoid°Modified Bitumen Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product,for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for tennination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors at.d shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-1020.01 and consists of pages 1 through 67.
The submitted documentation was reviewed by Jorge L. Acebo.
1
NOA No.: 18-0919.12
MIAMI•DADECOUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 1 of 67
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Categorv: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: -105 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
GAFGLAS"'Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet
(1 meter) Wide reinforced with fiberglass mat.
Tri-Ply"Ply 4 Ply Sheet 39.37' ASTM D2178 Smooth surfaced asphaltic ply sheet
(1 meter) Wide reinforced with fiberglass mat.
GAFGLASV' 39.37' ASTM D2178 Smooth surfaced asphaltic ply sheet
F1exP1yT'"6 (1 meter) Wide reinforced with fiberglass mat.
GAFGLAS'#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet
(1 meter) Wide reinforced with fiberglass mat.
Tri-Ply"'#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet
(1 meter) Wide reinforced with fiberglass mat.
GAFGLAS"'#80 Ultima'"Base 39.37' ASTM D4601 Smooth asphaltic base or base/ply sheet
Sheet (1 meter) Wide reinforced with fiberglass mat.
GAFGLAS'Stratavent" 39.37" ASTM D4897 Smooth surfaced asphaltic perforated
Perforated Venting Base Sheet (1 meter) Wide venting base sheet reinforced with
fiberglass mat.
GAFGLAS"Stratavent"' 39.37' ASTM D4897 Smooth surfaced asphaltic nailable venting
Nailable Venting Base Sheet (1 meter) Wide base sheet reinforced with fiberglass mat.
Bottom side surfaced with granules.
Ruberoid"HW 25 Smooth 39.37' ASTM D6163 Smooth surfaced torch applied SBS base
(1 meter) Wide or ply sheet reinforced with a fiberglass
mat.
Ruberoid"HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base
(1 meter) Wide or ply sheet reinforced with a polyester
mat.
Ruberoid`R'HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
Ruberoid"HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat-
(1 meter) Wide welded SBS cap sheet reinforced with a
polyester mat.
Ruberoid'HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
Ruberoid`"'HW Plus Granule 39.37' ASTM D6164 Fire retardant granule surfaced torch
FR (1 meter) Wide applied SBS cap sheet reinforced with a
polyester mat.
MIAM•DADECOUNTY NOA No.: 18-0919.12
.. b Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 2 of 67
Test Product
Product Dimensions Specification Description
Ruberoid®EnergyCap"HW 1 meter ASTM D6164 Fire retardant granule surfaced heat-
Plus Granule FR (39.37")Wide welded SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT""EnergyCote"
Elastomeric Coating.
Ruberoid"Torch Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP base
(I meter) Wide or ply sheet reinforced with a polyester
mat.
Tri-Ply`"'APP Smooth 3937" ASTM D6222 Smooth surfaced torch applied APP cap,
Membrane (I meter) Wide base or ply sheet reinforced with a
polyester mat.
Ruberoidkl'Torch Granule 39.37" ASTM D6222 Granule surfaced torch applied APP cap
(I meter) Wide sheet reinforced with a polyester mat.
Tri-Ply'APP Granule Cap 39.37" ASTM D6222 Granule surfaced torch applied APP cap
Sheet (I meter) Wide sheet reinforced with a polyester mat.
Ruberoido Torch Plus Granule 39.37" ASTM D6222 Fire retardant granule surfaced torch
FR (I meter) Wide applied APP cap sheet reinforced with a
polyester mat.
Ruberoid' EnergyCap" 39.37" ASTM D6222 Fire retardant granule surfaced torch
Torch Plus Granule FR (I meter) Wide applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT'EnergyCote'
Elastomeric Coating.
Ruberoidt'L EnergyCap" 39.37" ASTM D6222 Fire retardant granule surfaced torch
Torch Granule FR (I meter) Wide applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT"EnergyCote'
Elastomeric Coating.
Ruberoid'20 Smooth 39.37" ASTM D6163 SBS polymer-modified asphalt base or ply
(I meter) Wide sheet reinforced with a fiberglass mat.
Ruberoid'30 Granule 39.37" - ASTM D6163 Granule surfaced mop applied SBS cap
(I meter) Wide sheet reinforced with a fiberglass mat.
Ruberoid'30 Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop
(I meter) Wide applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid'30 Plus Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop
(I meter) Wide applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoie- Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap
(I meter) Wide sheet reinforced with a polyester mat.
Tri-Ply'SBS Granule Cap 3937 ASTM D6164 Granule surfaced mop applied SBS cap
Sheet (I meter)Wide sheet reinforced with a polyester mat.
Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap
(I meter) Wide sheet reinforced with a polyester mat.
Ruberoid'Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base
(I meter)Wide sheet reinforced with a polyester mat.
MIMI-DADE NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 3 of 67
Test Product
Product Dimensions Specification Description
Ruberoid'Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base
(1 meter) Wide sheet reinforced with a polyester mat.
Ruberoie Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or
(1 meter) Wide ply sheet reinforced with a polyester mat.
Ruberoid'"'Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap
(1 meter) Wide sheet reinforced with a polyester mat.
Ruberoid`"'Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop
FR (1 meter) Wide applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid'"'EnergyCap'" Mop 39.37" ASTM D6164 Fire retardant granule surfaced mop
Plus Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT`' EnergyCote'"
Elastomeric Coating.
Ruberoid'Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop
(1 meter) Wide applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid`"'EnergyCap"' 30 39.37" ASTM D6163 Fire retardant granule surfaced mop
Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a
fiberglass mat. Cap sheet is factory coated
with TOPCOAT"EnergyCote"
Elastomeric Coating.
GAFGLAS'�'Mineral-Surfaced 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet
Cap Sheet (1 meter)Wide reinforced with fiberglass mat.
Tri-Ply"'BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet
Sheet (1 meter)wide reinforced with a fiberglass mat.
GAFGLAS'EnergyCap— 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet
Mineral-Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet
is factory coated with TOPCOAT'
EnergyCote'"Elastomeric Coating.
TOPCOAT' Membrane 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating.
United Coatings"Roof Mate 1, 5 or 55 ASTM D6083 Water-based elastomeric coating
TCM Coating Gallons
TOPCOAT' 5 or 55 gallons ASTM D6083 Solvent based thermopla3tic rubber sealant
Surface Seal SB designed to protect and restore aged roof
surfaces and to increase roof reflectivity.
United Coatings'' Surface Seal 5 or 55 Gallons ASTM D6083 Solvent-based thermoplastic rubber
SB Roof Coating sealant designed to protect and restore
aged roof surfaces and to increase roof
reflectivity.
TOPCOAT"MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to
block asphalt bleed-through.
United Coatings'" Roof Mate 5 or 55 Gallons Proprietary Water based, low VOC primer designed to
MB Plus Coating block asphalt bleed-through.
NOA No.: 18-0919.12
CMIAM cout�rr�r Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 4 of 67
Test Product
Product Dimensions Specification Description
FireOut"Fire Barrier Coating 5 or 55 gallons Proprietary Low VOC,water-based fire barrier
coating.
Flex Seal" 1, 5 gallons TAS 139 Solvent-based elastomeric sealant.
or 1 qt. tube
VersaShield'Fire-Resistant 12"x 100' rolls ASTM D226 Non-asphaltic fiberglass-based
Roof Deck Protection underlayment and/or fire barrier.
VersaShield' Solo'Fire- 42" roll wide, ASTM D146, Non-asphaltic, fire resistant fiberglass
Resistant Slip Sheet 100 ft. D828,D4869, underlayment
D6757
MatrixTM 102 SBS Membrane 3, 5 or 55 gallons ASTM D3019 Fiber reinforced rubberized cold-applied
Adhesive adhesive for modified bitumen roof
systems.
APPROVED INSULATIONS:
Table 2
Product Name Product Description Manufacturer
(With Current NOA)
EnergyGuard'"Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuarcfm Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard7' RA Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard'"RH Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard'RH Tapered Polyiso Polyisocyanurate foam insulation GAF
Insulation
EnergyGuard"RN Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard'Perlite Recover Board Perlite recover board GAF
EnergyGuard"Perlite Roof Insulation Perlite insulation board GAIT
EnergyGuard'RA Composite Polyiso Polyisocyanurate-foam insulation GAF
Insulation with high density fiberboard or
permalite
StructodekO High Density Fiberboard Roof High density fiberboard Blue Ridge Fiberboard, Inc.
Insulation
SECUROCK`"'Gypsum-Fiber Roof Board Gypsum board United States Gypsum Corp.
SECUROCK'Glass-Mat Roof Board Gypsum board United States Gypsum Corp.
DensDece Roof Board Gypsum board Georgia-Pacific
DensDeck'Prime Roof Board Gypsum board Georgia-Pacific
MLAMI-DADE C • NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 5 of 67
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Drill-Tec"#12 Fastener Phillips head,modified #12 x 8" GAF
buttress thread,pinch Max. Length
point, carbon steel fastener #3 Phillips
for use in steel or wood head.
decks. With CR-10
coating. Available with a
pinch point or drill point.
2. Drill-Tee"'#14 Fastener Truss head, self-drilling, 914 x 16" GAF
pinch point,high thread Max. Length
fastener for use in steel, 43 Phillips
wood or concrete decks. head.
3. Drill-TecT"XHD Fastener Truss head, self-drilling, #15 x 16" GAF
pinch point,high thread Max.Length
fastener for use in wood or 93 Phillips
steel decks. Carbon steel head.
extra heavy duty fastener
used in steel decks.
4. Drill-Tec" 3" Steel Plate Round Galvalume`R'steel 3" Round GAF
stress plate with
reinforcing ribs and
recessed for use with Drill-
Tee"'fasteners.
5. Drill-Tec'" 3" Standard Galvalume"coated steel 3" Round GAF
Steel Plate stress plate for use with
approved Drill-Tec"
fasteners.
6. Drill-Tec"' ASAP 3S Drill-Tec'"#12 fastener 412 x 8" GAF
with Drill-TecT" 3" Max. Length
Standard Steel Plate. #3 Phillips
head with 3"
Round plate
7. Drill-Tec" AccuTrac"Flat A2-SS aluminized steel 3" square; GAF
Plate plate for use with Drill- .017" thick
Tee'" fasteners.
8. Drill-Tec" AccuTrac`"' Galvalume`"'steel plate 3" square; GAF
Recessed Plate with recess for use with .017" thick.
Drill-Tec"fasteners.
9. Drill-Tec" 3 in. Ribbed Round Galvalume"'plated 3"Round GAF
Galvalume Plate (Flat) steel stress plate with
reinforcing ribs for use
with Drill-TecT"' fasteners.
NOA No.: 18-0919.12
MIAMI-QADE COUNTY
...� � Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 6 of 67
EVIDENCE SUBMITTED:
Test Agency Test Identifier Description Date
FM Approvals 3001276 FMRC 4470 01/28/99
3010215 FMRC 4470 03/01/01
3029832 FMRC 4470 05/11/07
3036980 FMRC 4470 08/14/09
3034312 FMRC 4470 04/09/09
3040738 FMRC 4470 05/18/12
3042887 FMRC 4470 11/14/11
3046081 FMRC 4470 02/13/13
3043633 FMRC 4470 01/20/12
1B9A8.AM FMRC 4470 09/04/97
3B9Q1.AM FMRC 4470 01/08/08
3D4Q2.AM FMRC 4470 04/30/97
OD 1 A8.AM FMRC 4470 04/01/98
797-03221-267 FMRC 4470 09/24/07
797-10228-267 FMRC 4470 01/15/15
797-04694-267 FMRC 4470 06/17/09
797-03825-267 FMRC 4470 07/14/08
RR203450 FMRC 4470 12/04/15
FM Letter FMRC 4470 04/11/13
FM Letter FMRC 4470 09/15/15
UL LLC R1306 UL 790 08/21/18
IRT-ARCON Inc. 02-005 TAS 114-J 07/19/04
02-014 TAS 114-J 04/08/02
Trinity) ERD C8500SC.11.07 ASTM D6862 11/30/07
G30250.02.10-2 ASTM D6222 11/11/10
G30250.02.10-3-R2 ASTM D3909 06/03/15
G31360.03.10 ASTM D6164 03/31/10
G32520.06.11 ASTM D1876 06/28/11
G33470.01.11 ASTM D6164 01/13/11
G34140.04.11-2 ASTM D6163 04/25/11
G34140.04.11-4-R2 ASTM D4601 6/4/2015
G34140.04.11-5-R3 ASTM D4897 6/4/2015
G36780.07.11-R1 TAS 114-J 07/18/11
G40620.07.12-2 ASTM D6222 07/17/12
G40630.01.14-1 ASTM D6163 01/06/14
G40630.01.14-2A ASTM D5147 01/07/14
G40630.01.14-2A-1-R1 ASTM D6164 041/10/14
G40630.01.14-2B-R1 ASTM D6164 01/16/15
G40630.01.14-2C ASTM D6164 01/07/14
G40630.03.14 ASTM D5147 03/06/14
G43190.03.14-1 ASTM D5147 03/06/14
G43190.03.14-2 ASTM D5147 03/06/14
G43190.05.14-R1 ASTM D5147 05/20/14
G43610.01.14 ASTM D5147 01/22/14
NOA No.: 18-0919.12
Mui Fgjwwbj wecovrmm Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 7 of 67
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency Test Identifier Descrintion Date
Trinity) ERD G43190.11.13-1 ASTM D6222 11/15/13
G46160.02.15 ASTM D6163 02/12/15
G46160.02.15-213-1 ASTM D6163 02/09/16
646160.03.15 ASTM 136163 03/11/15
646160.09.14-2A ASTM D5147 09/09/14
G46160.09.14-3A ASTM D6164 09/09/14
G46160.09.14-3B ASTM D6164 09/09/14
G46160.09.14-3C ASTM D5147 09/09/14
G46160.12.14-3E ASTM D6164 12/29/14
G6850.08.08 ASTM D6163 08/01/08
G6850.08.08-R1 ASTM D6164 04/14/11
G6850.10.08 ASTM D6222 10/06/08
G6850.11.08 ASTM D6222 02/17/09
SC6870.08.14-R1 ASTM D3909 09/04/14
PRI Construction Materials GAF-122-02-01 TAS 139 051107/06
Technologies,LLC GAF-245-02-01 ASTM D6083 06/10/10
GAF-276-02-01 Rev ASTM E2178 01/04/11
ASTM D6083
GAF-306-02-01 ASTM E96 07/07/11
GAF-314-02-01 ASTM D2178 08/23/11
GAF-315-02-01 ASTM D2178 08/23/11
GAF-369-02-01 ASTM C1289 10/22/12
GAF-434-02-03 TAS 114-J 09/06/13
GAF-434-02-04 TAS 114-J 09/06/13
GAF-464-02-01 ASTM C1289 02/06/14
GAF-498-02-01 ASTM D6083 09/16/16
GAF-499-02-01 ASTM D6083 03/12/14
GAF-500-02-01 ASTM D6083 03/12/14
GAF-559-02-01 TAS 117(B) 09/30/14
GAF-559-02-04 ASTM D1876 10/01/14
GAF-559-02-05 ASTM D1876 10/15/14
GAF-559-02-06 TAS 114(11) 10/02/14
GAF-559-02-07 ASTM D903 10/02/14
GAF-559-02-08 ASTM D903 10/02/14
GAF-559-02-09 ASTM D903 10/02/14
GAF-559-02-11 TAS 114-J 10/14/14
GAF-559-02-12 TAS 114-J 10/14/14
GAF-559-02-13 TAS 114-J 10/15/14
GAF-559-02-14 TAS 114-J 10/15/14
GAF-559-02-15 TAS 114-J 10/15/14
GAF-559-02-16 TAS 114-J 10/15/14
GAF-559-02-18 TAS 114-J 10/15/14
GAF-559-02-19 TAS 114-J 04/16/15
Dynatech Engineering Corporation #4482.02.95-1 TAS 114-C 09/01/95
MIAMI-DADE COUNTY
NOA No.: 18-4919.12
��FXWVXWRIJ Expiration Date: 11/46/23
Approval Date: 11/01/18
Page 8 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type 1: Wood,Non-insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c.max.
System Type E(2): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems)
All General and System Limitations shall apply.
Fire Barrier: FireOut"'Fire Barrier Coating, VersaShieldo'Fire-Resistant Roof Deck
(optional) Protection, VersaShield' SoIoTM Fire-Resistant Slip Sheet, DensDeck'Roof
Board, SECUROCK'Gypsum-Fiber Roof Board or SECUROCW°`Glass-Mat
Roof Board.
Base sheet: GAFGLAS'#80 Ultima" Base Sheet, GAFGLAS'''Stratavento Nailable Venting
Base Sheet,Ruberoido Mop Smooth,Ruberoid'Mop Smooth 1.5,Ruberoid'
Mop Plus Smooth, Ruberoid"20 Smooth, Ruberoid'HW Smooth or Ruberoid'
HW 25 Smooth mechanically fastened to deck as described below;
Fastening GAFGLAS Ply 4,Tri-Ply""Ply 4 Ply Sheet GAFGLAS-'FlexPly' 6,
Option#1: GAFGLAS'#75 Base Sheet, y' #75 Base Sheet or any of above ase
ee attac e to dec with approved annulafting sank nails nd t' ca s at a
astener spacing o o.c. at the lap staggered and in two rows 18" o.c. in the
field.
of for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure—45 psf. See General Limitation#9)
Fastening GAFGLAS'Ply 4,Tri-Ply" Ply 4 Ply Sheet, GAFGLAS FlexPly" 6,
Option#2: GAFGLAS` #75 Base Sheet,Tri-Ply`''#75 Base Sheet or any of above base
sheets attached to deck with Drill-Tec"#12 Fastener or Drill-Tec'#14 Fastener
and Drill-Tee' 3" Steel Plate,Drill-TecT"AccuTrac"Flat Plate or Drill-TecTI
AccuTrac'Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 12.5"o.c. in the field of
the sheet.
(Maximum Design Pressure—45 psf. See General Limitation#9)
Fastening GAFGLAS FlexPly` 6, GAFGLASO' #75 Base Sheet,Tri-Ply#75 Base Sheet
Option#3: or any of above base sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in
two rows 9" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure—52.5 psf. See General Limitation #7)
Fastening GAFGLAS'#75 Base Sheet,Tri-Ply""#75 Base Sheet or any of above base
Option#4: sheets attached to deck with Drill-Tec"#12 Fastener or Drill-Tec,',#14 Fastener
and Drill-Tec" 3" Steel Plate,Drill-Tec*" AccuTrac'Flat Plate or Drill-TecTb'
AccuTracl Recessed Plate installed 12"o.c. in 4 rows. One row is :n the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure—45 psf. See General Limitation#9)
NOA No.: 18-0919.12
MIAMI RADE COUNTY Expiration Date: 11/06/23
b Approval Date: 11/01/18
Page 53 of 67
Fastening GAFGLAS`"'#80 Ultima'Base Sheet,Ruberoid'20 Smooth,Ruberoid`"'Mop
Option#5: Smooth base sheet attached to deck approved.annular ring shank nails and 3"
inverted Drill-TecT" 3" Steel Plate at a fastener spacing of 9" o.c. at the 4"lap
staggered in two rows 9" in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure—60 psf. See General Limitation#7)
Fastening GAFGLAS#75 Base Sheet,Tri-Ply's#75 Base Sheet or any of above base
Option#6: sheets attached to deck with Drill-Tec"#12Fastener, Drill-TecT" #14 Fastener or
Drill-Tec'"XHD Fastener and Drill-TecT"' 3" Steel Plate,Drill-TecT"AccuTrac@
Flat Plate or Drill-TecT"AccuTrac'-"Recessed Plate installed 8"o.c. in 4 rows.
One row is in the 2"side lap. The other rows are equally spaced approximately
9" o.c. in the field of the sheet.
(Maximum Design Pressure—45 psf. See General Limitation#9)
Ply Sheet: (Optional except over Ruberoid`"'Mop Smooth, Ruberoid'Mop Smooth 1.5,
Ruberoid'Mop Plus Smooth,Ruberoid''20 Smooth,Ruberoid"HW Smooth or
Ruberoie HW 25 Smooth) One or more plies GAFGLAS``Ply 4,Tri-Ply`' Ply 4,
or GAFGLAS`"'F1exPlyT"' 6 sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid"Torch
Smooth torch applied according to manufacturer's application instructions.
Membrane: One ply of Ruberoid"Torch Smooth,Tri-Ply'APP Smooth Membrane,
Ruberoid``'Torch Granule, Tri-Ply`' APP Granule Cap Sheet, , Ruberoid'
EnergyCap'Torch Granule FR,Ruberoid'-Lo EnergyCapT"Torch Plus Granule FR,
or Ruberoid``Torch Plus Granule FR torch applied according to manufacturer's
application instructions.
Or
One or more plies of Ruberoid'HW Plus Granule, Ruberoid'HW Plus Granule
FR,Ruberoid` HW Granule FR, Ruberoid'EnergyCapT"HW Plus Granule FR,
Ruberoid- HW Granule,Ruberoid'HW Smooth and Ruberoid'HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS'Mineral-Surfaced Cap Sheet,Tri-Ply'BUR Granule Cap Sheet
or GAFGLAS`" EnergyCapT' Mineral-Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAT'Surface Seal SB or United Coatings" Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat.
OR
TOPCOATr"'MB Plus or United Coatings"Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by
TOPCOAT'Membrane or United Coatings'Roof Mate TCM Coating
applied in one or more coats at a miniinum rate of 1.0 gal./sq.per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
MIAMI•DADE COUNTY
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 54 of 67
i
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS"Ply 4 and GAFGLAS"F1exP1yT" 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum 1/4"DensDecle Roof Board or 1/2"Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt,panel size shall be 4' x 4'maxiinum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped b" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of
275 1b£, as tested in compliance with Testing Application Standard TAS 105. if the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required,as determined by the
Building Official, a revised fastener spacing,prepared, signed and sealed by a Florida Registered
Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation#9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field,perimeters, and corners). Neither rational analysis,nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones(i.e.perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation#7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE