HomeMy WebLinkAboutProduct Approval rtVIEWER FOR ZAP` MlAMl-DADE 1 )PA L��11,�;�ADE COUNTY R :lQ41CT CON Y R'OL SECTION -1' 05�S3 4b!Stret,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) j.:"°$.�� Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION RECEIV 6)315-290 F(786)315-2599 NOTICE OF ACCEPTANCE NOA www.mia dade.aov/econom GAF AUG 2 6 "M 1 Campus Drive Parsippany,NJ 07054 ST. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction'(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid°Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for tennination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors at.d shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-1020.01 and consists of pages 1 through 67. The submitted documentation was reviewed by Jorge L. Acebo. 1 NOA No.: 18-0919.12 MIAMI•DADECOUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 1 of 67 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Categorv: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS"'Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply"Ply 4 Ply Sheet 39.37' ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLASV' 39.37' ASTM D2178 Smooth surfaced asphaltic ply sheet F1exP1yT'"6 (1 meter) Wide reinforced with fiberglass mat. GAFGLAS'#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply"'#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS"'#80 Ultima'"Base 39.37' ASTM D4601 Smooth asphaltic base or base/ply sheet Sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS'Stratavent" 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base Sheet (1 meter) Wide venting base sheet reinforced with fiberglass mat. GAFGLAS"Stratavent"' 39.37' ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Venting Base Sheet (1 meter) Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid"HW 25 Smooth 39.37' ASTM D6163 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a fiberglass mat. Ruberoid"HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a polyester mat. Ruberoid`R'HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid"HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat- (1 meter) Wide welded SBS cap sheet reinforced with a polyester mat. Ruberoid'HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid`"'HW Plus Granule 39.37' ASTM D6164 Fire retardant granule surfaced torch FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. MIAM•DADECOUNTY NOA No.: 18-0919.12 .. b Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 2 of 67 Test Product Product Dimensions Specification Description Ruberoid®EnergyCap"HW 1 meter ASTM D6164 Fire retardant granule surfaced heat- Plus Granule FR (39.37")Wide welded SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT""EnergyCote" Elastomeric Coating. Ruberoid"Torch Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP base (I meter) Wide or ply sheet reinforced with a polyester mat. Tri-Ply`"'APP Smooth 3937" ASTM D6222 Smooth surfaced torch applied APP cap, Membrane (I meter) Wide base or ply sheet reinforced with a polyester mat. Ruberoidkl'Torch Granule 39.37" ASTM D6222 Granule surfaced torch applied APP cap (I meter) Wide sheet reinforced with a polyester mat. Tri-Ply'APP Granule Cap 39.37" ASTM D6222 Granule surfaced torch applied APP cap Sheet (I meter) Wide sheet reinforced with a polyester mat. Ruberoido Torch Plus Granule 39.37" ASTM D6222 Fire retardant granule surfaced torch FR (I meter) Wide applied APP cap sheet reinforced with a polyester mat. Ruberoid' EnergyCap" 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Plus Granule FR (I meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT'EnergyCote' Elastomeric Coating. Ruberoidt'L EnergyCap" 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Granule FR (I meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT"EnergyCote' Elastomeric Coating. Ruberoid'20 Smooth 39.37" ASTM D6163 SBS polymer-modified asphalt base or ply (I meter) Wide sheet reinforced with a fiberglass mat. Ruberoid'30 Granule 39.37" - ASTM D6163 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a fiberglass mat. Ruberoid'30 Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop (I meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid'30 Plus Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop (I meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoie- Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a polyester mat. Tri-Ply'SBS Granule Cap 3937 ASTM D6164 Granule surfaced mop applied SBS cap Sheet (I meter)Wide sheet reinforced with a polyester mat. Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a polyester mat. Ruberoid'Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (I meter)Wide sheet reinforced with a polyester mat. MIMI-DADE NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 3 of 67 Test Product Product Dimensions Specification Description Ruberoid'Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. Ruberoie Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid'"'Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid`"'Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid'"'EnergyCap'" Mop 39.37" ASTM D6164 Fire retardant granule surfaced mop Plus Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT`' EnergyCote'" Elastomeric Coating. Ruberoid'Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid`"'EnergyCap"' 30 39.37" ASTM D6163 Fire retardant granule surfaced mop Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a fiberglass mat. Cap sheet is factory coated with TOPCOAT"EnergyCote" Elastomeric Coating. GAFGLAS'�'Mineral-Surfaced 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Cap Sheet (1 meter)Wide reinforced with fiberglass mat. Tri-Ply"'BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter)wide reinforced with a fiberglass mat. GAFGLAS'EnergyCap— 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Mineral-Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet is factory coated with TOPCOAT' EnergyCote'"Elastomeric Coating. TOPCOAT' Membrane 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating. United Coatings"Roof Mate 1, 5 or 55 ASTM D6083 Water-based elastomeric coating TCM Coating Gallons TOPCOAT' 5 or 55 gallons ASTM D6083 Solvent based thermopla3tic rubber sealant Surface Seal SB designed to protect and restore aged roof surfaces and to increase roof reflectivity. United Coatings'' Surface Seal 5 or 55 Gallons ASTM D6083 Solvent-based thermoplastic rubber SB Roof Coating sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. TOPCOAT"MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed-through. United Coatings'" Roof Mate 5 or 55 Gallons Proprietary Water based, low VOC primer designed to MB Plus Coating block asphalt bleed-through. NOA No.: 18-0919.12 CMIAM cout�rr�r Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 4 of 67 Test Product Product Dimensions Specification Description FireOut"Fire Barrier Coating 5 or 55 gallons Proprietary Low VOC,water-based fire barrier coating. Flex Seal" 1, 5 gallons TAS 139 Solvent-based elastomeric sealant. or 1 qt. tube VersaShield'Fire-Resistant 12"x 100' rolls ASTM D226 Non-asphaltic fiberglass-based Roof Deck Protection underlayment and/or fire barrier. VersaShield' Solo'Fire- 42" roll wide, ASTM D146, Non-asphaltic, fire resistant fiberglass Resistant Slip Sheet 100 ft. D828,D4869, underlayment D6757 MatrixTM 102 SBS Membrane 3, 5 or 55 gallons ASTM D3019 Fiber reinforced rubberized cold-applied Adhesive adhesive for modified bitumen roof systems. APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard'"Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuarcfm Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard7' RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'"RH Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'RH Tapered Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard"RN Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'Perlite Recover Board Perlite recover board GAF EnergyGuard"Perlite Roof Insulation Perlite insulation board GAIT EnergyGuard'RA Composite Polyiso Polyisocyanurate-foam insulation GAF Insulation with high density fiberboard or permalite StructodekO High Density Fiberboard Roof High density fiberboard Blue Ridge Fiberboard, Inc. Insulation SECUROCK`"'Gypsum-Fiber Roof Board Gypsum board United States Gypsum Corp. SECUROCK'Glass-Mat Roof Board Gypsum board United States Gypsum Corp. DensDece Roof Board Gypsum board Georgia-Pacific DensDeck'Prime Roof Board Gypsum board Georgia-Pacific MLAMI-DADE C • NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 5 of 67 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec"#12 Fastener Phillips head,modified #12 x 8" GAF buttress thread,pinch Max. Length point, carbon steel fastener #3 Phillips for use in steel or wood head. decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-Tee"'#14 Fastener Truss head, self-drilling, 914 x 16" GAF pinch point,high thread Max. Length fastener for use in steel, 43 Phillips wood or concrete decks. head. 3. Drill-TecT"XHD Fastener Truss head, self-drilling, #15 x 16" GAF pinch point,high thread Max.Length fastener for use in wood or 93 Phillips steel decks. Carbon steel head. extra heavy duty fastener used in steel decks. 4. Drill-Tec" 3" Steel Plate Round Galvalume`R'steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill- Tee"'fasteners. 5. Drill-Tec'" 3" Standard Galvalume"coated steel 3" Round GAF Steel Plate stress plate for use with approved Drill-Tec" fasteners. 6. Drill-Tec"' ASAP 3S Drill-Tec'"#12 fastener 412 x 8" GAF with Drill-TecT" 3" Max. Length Standard Steel Plate. #3 Phillips head with 3" Round plate 7. Drill-Tec" AccuTrac"Flat A2-SS aluminized steel 3" square; GAF Plate plate for use with Drill- .017" thick Tee'" fasteners. 8. Drill-Tec" AccuTrac`"' Galvalume`"'steel plate 3" square; GAF Recessed Plate with recess for use with .017" thick. Drill-Tec"fasteners. 9. Drill-Tec" 3 in. Ribbed Round Galvalume"'plated 3"Round GAF Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-TecT"' fasteners. NOA No.: 18-0919.12 MIAMI-QADE COUNTY ...� � Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 6 of 67 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date FM Approvals 3001276 FMRC 4470 01/28/99 3010215 FMRC 4470 03/01/01 3029832 FMRC 4470 05/11/07 3036980 FMRC 4470 08/14/09 3034312 FMRC 4470 04/09/09 3040738 FMRC 4470 05/18/12 3042887 FMRC 4470 11/14/11 3046081 FMRC 4470 02/13/13 3043633 FMRC 4470 01/20/12 1B9A8.AM FMRC 4470 09/04/97 3B9Q1.AM FMRC 4470 01/08/08 3D4Q2.AM FMRC 4470 04/30/97 OD 1 A8.AM FMRC 4470 04/01/98 797-03221-267 FMRC 4470 09/24/07 797-10228-267 FMRC 4470 01/15/15 797-04694-267 FMRC 4470 06/17/09 797-03825-267 FMRC 4470 07/14/08 RR203450 FMRC 4470 12/04/15 FM Letter FMRC 4470 04/11/13 FM Letter FMRC 4470 09/15/15 UL LLC R1306 UL 790 08/21/18 IRT-ARCON Inc. 02-005 TAS 114-J 07/19/04 02-014 TAS 114-J 04/08/02 Trinity) ERD C8500SC.11.07 ASTM D6862 11/30/07 G30250.02.10-2 ASTM D6222 11/11/10 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G32520.06.11 ASTM D1876 06/28/11 G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015 G36780.07.11-R1 TAS 114-J 07/18/11 G40620.07.12-2 ASTM D6222 07/17/12 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D5147 01/07/14 G40630.01.14-2A-1-R1 ASTM D6164 041/10/14 G40630.01.14-2B-R1 ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01/07/14 G40630.03.14 ASTM D5147 03/06/14 G43190.03.14-1 ASTM D5147 03/06/14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R1 ASTM D5147 05/20/14 G43610.01.14 ASTM D5147 01/22/14 NOA No.: 18-0919.12 Mui Fgjwwbj wecovrmm Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 7 of 67 EVIDENCE SUBMITTED: (CONTINUED) Test Agency Test Identifier Descrintion Date Trinity) ERD G43190.11.13-1 ASTM D6222 11/15/13 G46160.02.15 ASTM D6163 02/12/15 G46160.02.15-213-1 ASTM D6163 02/09/16 646160.03.15 ASTM 136163 03/11/15 646160.09.14-2A ASTM D5147 09/09/14 G46160.09.14-3A ASTM D6164 09/09/14 G46160.09.14-3B ASTM D6164 09/09/14 G46160.09.14-3C ASTM D5147 09/09/14 G46160.12.14-3E ASTM D6164 12/29/14 G6850.08.08 ASTM D6163 08/01/08 G6850.08.08-R1 ASTM D6164 04/14/11 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 02/17/09 SC6870.08.14-R1 ASTM D3909 09/04/14 PRI Construction Materials GAF-122-02-01 TAS 139 051107/06 Technologies,LLC GAF-245-02-01 ASTM D6083 06/10/10 GAF-276-02-01 Rev ASTM E2178 01/04/11 ASTM D6083 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-434-02-03 TAS 114-J 09/06/13 GAF-434-02-04 TAS 114-J 09/06/13 GAF-464-02-01 ASTM C1289 02/06/14 GAF-498-02-01 ASTM D6083 09/16/16 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D1876 10/01/14 GAF-559-02-05 ASTM D1876 10/15/14 GAF-559-02-06 TAS 114(11) 10/02/14 GAF-559-02-07 ASTM D903 10/02/14 GAF-559-02-08 ASTM D903 10/02/14 GAF-559-02-09 ASTM D903 10/02/14 GAF-559-02-11 TAS 114-J 10/14/14 GAF-559-02-12 TAS 114-J 10/14/14 GAF-559-02-13 TAS 114-J 10/15/14 GAF-559-02-14 TAS 114-J 10/15/14 GAF-559-02-15 TAS 114-J 10/15/14 GAF-559-02-16 TAS 114-J 10/15/14 GAF-559-02-18 TAS 114-J 10/15/14 GAF-559-02-19 TAS 114-J 04/16/15 Dynatech Engineering Corporation #4482.02.95-1 TAS 114-C 09/01/95 MIAMI-DADE COUNTY NOA No.: 18-4919.12 ��FXWVXWRIJ Expiration Date: 11/46/23 Approval Date: 11/01/18 Page 8 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 1: Wood,Non-insulated Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(2): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut"'Fire Barrier Coating, VersaShieldo'Fire-Resistant Roof Deck (optional) Protection, VersaShield' SoIoTM Fire-Resistant Slip Sheet, DensDeck'Roof Board, SECUROCK'Gypsum-Fiber Roof Board or SECUROCW°`Glass-Mat Roof Board. Base sheet: GAFGLAS'#80 Ultima" Base Sheet, GAFGLAS'''Stratavento Nailable Venting Base Sheet,Ruberoido Mop Smooth,Ruberoid'Mop Smooth 1.5,Ruberoid' Mop Plus Smooth, Ruberoid"20 Smooth, Ruberoid'HW Smooth or Ruberoid' HW 25 Smooth mechanically fastened to deck as described below; Fastening GAFGLAS Ply 4,Tri-Ply""Ply 4 Ply Sheet GAFGLAS-'FlexPly' 6, Option#1: GAFGLAS'#75 Base Sheet, y' #75 Base Sheet or any of above ase ee attac e to dec with approved annulafting sank nails nd t' ca s at a astener spacing o o.c. at the lap staggered and in two rows 18" o.c. in the field. of for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—45 psf. See General Limitation#9) Fastening GAFGLAS'Ply 4,Tri-Ply" Ply 4 Ply Sheet, GAFGLAS FlexPly" 6, Option#2: GAFGLAS` #75 Base Sheet,Tri-Ply`''#75 Base Sheet or any of above base sheets attached to deck with Drill-Tec"#12 Fastener or Drill-Tec'#14 Fastener and Drill-Tee' 3" Steel Plate,Drill-TecT"AccuTrac"Flat Plate or Drill-TecTI AccuTrac'Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) Fastening GAFGLAS FlexPly` 6, GAFGLASO' #75 Base Sheet,Tri-Ply#75 Base Sheet Option#3: or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—52.5 psf. See General Limitation #7) Fastening GAFGLAS'#75 Base Sheet,Tri-Ply""#75 Base Sheet or any of above base Option#4: sheets attached to deck with Drill-Tec"#12 Fastener or Drill-Tec,',#14 Fastener and Drill-Tec" 3" Steel Plate,Drill-Tec*" AccuTrac'Flat Plate or Drill-TecTb' AccuTracl Recessed Plate installed 12"o.c. in 4 rows. One row is :n the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) NOA No.: 18-0919.12 MIAMI RADE COUNTY Expiration Date: 11/06/23 b Approval Date: 11/01/18 Page 53 of 67 Fastening GAFGLAS`"'#80 Ultima'Base Sheet,Ruberoid'20 Smooth,Ruberoid`"'Mop Option#5: Smooth base sheet attached to deck approved.annular ring shank nails and 3" inverted Drill-TecT" 3" Steel Plate at a fastener spacing of 9" o.c. at the 4"lap staggered in two rows 9" in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—60 psf. See General Limitation#7) Fastening GAFGLAS#75 Base Sheet,Tri-Ply's#75 Base Sheet or any of above base Option#6: sheets attached to deck with Drill-Tec"#12Fastener, Drill-TecT" #14 Fastener or Drill-Tec'"XHD Fastener and Drill-TecT"' 3" Steel Plate,Drill-TecT"AccuTrac@ Flat Plate or Drill-TecT"AccuTrac'-"Recessed Plate installed 8"o.c. in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) Ply Sheet: (Optional except over Ruberoid`"'Mop Smooth, Ruberoid'Mop Smooth 1.5, Ruberoid'Mop Plus Smooth,Ruberoid''20 Smooth,Ruberoid"HW Smooth or Ruberoie HW 25 Smooth) One or more plies GAFGLAS``Ply 4,Tri-Ply`' Ply 4, or GAFGLAS`"'F1exPlyT"' 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid"Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of Ruberoid"Torch Smooth,Tri-Ply'APP Smooth Membrane, Ruberoid``'Torch Granule, Tri-Ply`' APP Granule Cap Sheet, , Ruberoid' EnergyCap'Torch Granule FR,Ruberoid'-Lo EnergyCapT"Torch Plus Granule FR, or Ruberoid``Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid'HW Plus Granule, Ruberoid'HW Plus Granule FR,Ruberoid` HW Granule FR, Ruberoid'EnergyCapT"HW Plus Granule FR, Ruberoid- HW Granule,Ruberoid'HW Smooth and Ruberoid'HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS'Mineral-Surfaced Cap Sheet,Tri-Ply'BUR Granule Cap Sheet or GAFGLAS`" EnergyCapT' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT'Surface Seal SB or United Coatings" Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOATr"'MB Plus or United Coatings"Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT'Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a miniinum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 54 of 67 i WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS"Ply 4 and GAFGLAS"F1exP1yT" 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4"DensDecle Roof Board or 1/2"Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4' x 4'maxiinum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped b" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 1b£, as tested in compliance with Testing Application Standard TAS 105. if the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official, a revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,perimeters, and corners). Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-0919.12 Cma� ECOUNTY Expiration Date: 11/06/23 to YJ 4?J Approval Date: 11/01/18 Page 67 of 67