HomeMy WebLinkAboutProduct Approval 2/131/2018 Florida Building Code Online
Business e.
l
ti
i rrrccc���hhh
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats&Facts Publ catlo c Sta BCIS to Nlpp e rch
ab
a
a
�Product Approval
lix�kUSER:Public User
Product Approval Menu>Product or Application Search>AApplication List>Application Detail ^
• • FL# FL R1 R tIEWEF.) FOR
Application Type Revision vision
Code Version 2017 CODE COMPLIANCE
Application Status Approved
STa LUGIE COUNTY
Comments q-)Cc
i Archived I:
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
I '
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
rchard@emfab.net
i
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
?"+ Validation Checklist-Hardcopy Received
Certificate of Independence L2F 0378_R1 COI FL 20378.1 NAILSTRIP 1.0 .032 ALUM sSS.Ddf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
i
Equivalence of Product Standards
Certified By
Sections from the Code
I '
hff s:/Iwww.floridabuilding.org/prfpr app_dti.aspx?param=wGEVXQwtDqua°/p2flMZ8n5CNV4ZYkew5Zoap/`2fE%2fovztglbhDVU2dJO4TAAp/o3dp/o3d 1/4
I
a o
t '
I
2/13/2018 Florida Building Code Online
i
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
I
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
i
FL# Model,Number or Name Description
20378.1 01-"1"Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1 II FL 20378.1 NAILSTRIP 1.0 .032
Approved for use outside HVHZ:Yes ALUM_sss.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_RI AE FL 20378.1 NAILSTRIP 1.0 .032
instructions. ALUM_sss.Ddf
Created by Independent Third Party:Yes
20376.2 02-"1"Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1 II FL 20378.2 Extreme Metal Fabricators 26GA
Approved for use outside HVHZ:Yes NAIL STRIP 1.0.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1 AE FL 20378.2 Extreme Metal Fabricators
instructions. 26GA NAIL STRIP 1.0.pdf
Created by Independent Third Party:Yes
20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.4 04-"1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_Ri_II FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378—RI_AE_FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.5 05-"Rib Panel" 29-gauge Steel exposed fastener roof panel,36"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.5 RIB 29GA ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1 AE FL 20378.5 RIB 29GA ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
dti.as x� =wGEVXQwtDqua°/"2flMZ8n5CNV4ZYkew5Zoa%2fE°/" lbhDVU2dJO4TAA 2fovzt °/"3d°/"3d 2/4
https://www.floridabuilding.org/pr/pr app_ aram p .p q
L
2/13/2018 Florida Building Code Online
20378.6 06-"5V Crimp" 26-gauge Steel exposed fastener roof panel,24"wide,
mechanically attached to 15/32"Plywood or Wood Deck
w/fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1_II FL 20378.E V Crim-_SSs.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Method 1 and Method 2 FL20378_R1 AE FL 20378.6 5V Crimp sss.Ddf
fastening. Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes
manufacturer's installation instructions.
20378.7 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips,fasteners and adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1 II FL 20378.7 JM STANDING SEAM ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1 AE FL 20378.7 JM STANDING SEAM ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.8 08-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
15/32"plywood or Wood Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_RI II_FL 20378.8 NORDMAN TILE 24GA ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1 AE FL 20378.8 NORDMAN TILE 24GA ssr.Ddf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1 II FL 20378.9 Nordman Tile Details-ssr.Ddf
Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E. @ CBUCK Engineering P.E.
Impact Resistant: No #31242
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1 AE FL 20378.9 Nordman Tile Details-ssr.Ddf
instructions. Created by Independent Third Party:Yes
20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached
to 15/32"plywood or Wood Deck with fasteners.
I
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378 RI II FL 20378.10 NORD TILT.032 ALUM-ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_Rl_AE_FL 20378.10 NORD TILT.032 ALUM-ssr.Ddf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.CopyAyht 2007-2013 State of Florida.::Privagr,Statement::Accessibility,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
eChel.
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2fMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d°/"3d 3/4
Product Report Manufacturer: Extreme,Metal Fabricator�.LL
2160 SW Poma Drive
Palm City, FL 34990
(-:772) 872-8034
Product
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant : Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3
Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min.
Attached 24" OA2 specific gravity with screws.24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506, 1507
Fastener for Method 1 Attachment# 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru wood decking
Fastener for Method 2 Attachment#9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru 15/32"min. plywood deck or 5/8"into wood plank
i
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT
DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 1 IN RIB PEAKS
ROW SPACING 12"O.C. 12"O.C. METHOD 21N PANELFLATS
FASTENER SPACING 12" O.C. 12"O.C. 'SEE INSTALL DRAWINGS
FASTENER SIZE: 0 #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1
Reference Data: HURRICANE TEST LAB#TST ID: 1527
TAS 125-03 Test#0223-0307-01;METHOD i (UL 1897-041)
TAS-125-03 Test#0223-0517-06,METHOD 2
EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD *DESIGN PRESSURE SAFETY MARIGIN 2:1
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributing products
under this evaluation. N. � t I I-j�rr..
Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or distributin fo Gtc�s ndef.:t�iiy��
i report. -`�C> "y' .
P��VL.
w v /
ftli:l:3l{�J1
Io
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
6th ed.,with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 6th ed•'Section 1507.1.1
f 2. Products are compliant for State of Florida product approval per Rule 61G20-3
3. Compliance Method: 1-D
4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
5. All support framing compliant w/Florida Building Code 2017,Chapters 22 for Steel,23 for Wood and 16 for
Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval'by local
authorities,authorized by the code,and is the responsibility of others.
7. This report does not imply warranty,installation,recommended product use outside of this report.
Fasteriks-
49-15 Hex-Head Screws With 5Wcrimp" Roof Panel
EPDN1 Bonded Steel Washers
���'y u,�•ius=!u�i }ic ty.�;}�;t�i'1�ikifi*fit G�i�i!uvi,:��� �t LL^y#14�`Y}yr,4t1'���� urea,
l *`r
3�. :v3sl>:
Deck:
-15.Gt or greater Plywood,of
.=Wood plank
i
Fasteners-
#9-15 Flex-Head Screws With 5V Crimp" Roof Panel
EPDM Bonded Steel Washers
jtat
y � �j i� s � J�}, ! I!},�i.t 3 4t�'~•�.11�jl-'�
;� _.�.rf�/AZa.Flf.:l-f�4'.":tL r/i2•Gs:f.✓,i4 -�'����� �"��rf�
ti
} f a. II i Sr�t�'1;•
y
ul �
AL
t—Deck:
-15132"or greater Plywood,or
-Wood plank
I
I
I
I